Screw Loosening for Standard and Wide Diameter Implants in Partially Edentulous Cases: 3- to 7-Year Longitudinal Data
Authors:
- Sang-Choon ChoSCSang-Choon Cho
- Paula-Naomi SmallPSPaula-Naomi Small
- Nicolas ElianNENicolas Elian
- Dennis TarnowDTDennis Tarnow
- 1 September 2004
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Implant Dentistry
- Vol. 13 (3) , 245-250
Abstract
Screw loosening is considered to be a common problem with both screw - retained and cemented implant restorations. A wider abutment platform, as well as using a torque driver to tighten specifically designed screws may help prevent this loosening. However, there has been no clinical study evaluating either of these. To longitudinally compare the frequency of screw loosening in standard diameter, (3.75 and 4.0 mm) implant supported prostheses to that of wide diameter, (5.0 and 6.0 mm) implant supported prostheses that were hand tightened, and to evaluate whether using a torque driver would minimize or prevent this problem, if screw loosening occurred. A total of 213 dental implants in 106 patients were included in this prospective longitudinal study. Of the implants 68 were wide diameter and 145 were standard diameter implants. Wide diameter implants showed 5.8% screw loosening, while standard diameter implants showed 14.5% screw loosening after insertion with only hand torquing. When these loose screws were tightened with a torque driver, there was no more loosening of screws. Within the limitations of this study, the wide diameter implants tested showed less screw loosening than the standard diameter implants when hand torqued. Additionally, within the scope of our study, using a torque driver to tighten the screws with the recommended force prevented this loosening from reoccurring in all cases.Keywords
This publication has 9 references indexed in Scilit:
- Spline™ Implant Prospective Multicenter Study: Interim Report on Prosthetic Screw Stability in Partially Edentulous PatientsJournal of Esthetic and Restorative Dentistry, 2002
- Effect of an antirotation resistance form on screw loosening for single implant-supported crownsThe Journal of Prosthetic Dentistry, 2000
- Clinical complications of osseointegrated implantsThe Journal of Prosthetic Dentistry, 1999
- Evaluation of the effectiveness of a technique to prevent screw looseningThe Journal of Prosthetic Dentistry, 1998
- IMPLANT SCREW MECHANICSDental Clinics of North America, 1998
- Retrospective multicenter analysis of 3i endosseous dental implants placed over a five‐year periodClinical Oral Implants Research, 1996
- Replacement of maxillary and mandibular molars with single endosseous implant restorations: A retrospective studyThe Journal of Prosthetic Dentistry, 1995
- A study of 589 consecutive implants supporting complete fixed prostheses. Part II: Prosthetic aspectsThe Journal of Prosthetic Dentistry, 1992
- The longitudinal clinical effectiveness of osseointegrated dental implants: The Toronto study. Part III: Problems and complications encounteredThe Journal of Prosthetic Dentistry, 1990