In Situ Gamma-ray Spectrometry Using an LaBr3(Ce) Scintillation Detector
Authors:
Open Access
- 30 September 2018
- journal article
- Published by Korean Association for Radiation Protection in Journal of Radiation Protection and Research
- Vol. 43 (3) , 85-96
Abstract
Background: A variety of inorganic scintillators have been developed and improved for use in radiation detection and measurement, and in situ gamma-ray spectrometry in the environment remains an important area in nuclear safety. In order to verify the feasibility of promising scintillators in an actual environment, a performance test is necessary to identify gamma-ray peaks and calculate the radioactivity from their net count rates in peaks. Materials and Methods: Among commercially available scintillators, LaBr3(Ce) scintillators have so far shown the highest energy resolution when detecting and identifying gamma-rays. However, the intrinsic background of this scintillator type affects efficient application to the environment with a relatively low count rate. An algorithm to subtract the intrinsic background was consequently developed, and the in situ calibration factor at 1 m above ground level was calculated from Monte Carlo simulation in order to determine the radioactivity from the measured net count rate. Results and Discussion: The radioactivity of six natural radionuclides in the environment was evaluated from in situ gamma-ray spectrometry using an LaBr3(Ce) detector. The results were then compared with those of a portable high purity Ge (HPGe) detector with in situ object counting system (ISOCS) software at the same sites. In addition, the radioactive cesium in the ground of Jeju Island, South Korea, was determined with the same assumption of the source distribution between measurements using two detectors. Conclusion: Good agreement between both detectors was achieved in the in situ gamma-ray spectrometry of natural as well as artificial radionuclides in the ground. This means that an LaBr3(Ce) detector can produce reliable and stable results of radioactivity in the ground from the measured energy spectrum of incident gamma-rays at 1 m above the ground.Keywords
Funding Information
- Ministry of Science and ICT
- National Research Foundation of Korea (2017M2A8A4015256)
This publication has 12 references indexed in Scilit:
- A New Approach for the Determination of Dose Rate and Radioactivity for Detected Gamma Nuclides Using an Environmental Radiation Monitor Based on an NaI(Tl) DetectorHealth Physics, 2017
- Spectrum–dose conversion operator of NaI(Tl) and CsI(Tl) scintillation detectors for air dose rate measurement in contaminated environmentsJournal of Environmental Radioactivity, 2017
- Simultaneous Determination of the Depth of an Embedded Source and its Radioactivity in the MediumHealth Physics, 2016
- Performance evaluation of newly developed SrI2(Eu) scintillatorNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2016
- In situ gamma-ray spectrometry in the environment using dose rate spectroscopyRadiation Physics and Chemistry, 2016
- In Situ Gamma Spectrometry Intercomparison in Fukushima, JapanJapanese Journal of Health Physics, 2015
- Scintillation and detection characteristics of high-sensitivity CeBr3 gamma-ray spectrometersNuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 2013
- Scintillators With Potential to Supersede Lanthanum BromideIEEE Transactions on Nuclear Science, 2009
- Characterization of LaBr3: Ce and LaCl3: Ce scintillators for gamma-ray spectroscopyJournal of Radioanalytical and Nuclear Chemistry, 2008
- Performance Comparison of a Large Volume CZT Semiconductor Detector and a LaBr$_3$(Ce) Scintillator DetectorIEEE Transactions on Nuclear Science, 2006