Shearlet-based compressed sensing for fast 3D cardiac MR imaging using iterative reweighting
Authors:
- Jackie MaJMJackie Ma
- Maximilian MärzMMMaximilian März
- Stephanie FunkSFStephanie Funk
- Jeanette Schulz-MengerJSJeanette Schulz-Menger
- Gitta KutyniokGKGitta Kutyniok
- Tobias SchaeffterTSTobias Schaeffter
- Christoph KolbitschCKChristoph Kolbitsch
Preprint
Abstract
High-resolution three-dimensional (3D) cardiovascular magnetic resonance (CMR) is a valuable medical imaging technique, but its widespread application in clinical practice is hampered by long acquisition times. Here we present a novel compressed sensing (CS) reconstruction approach using shearlets as a sparsifying transform allowing for fast 3D CMR (3DShearCS). Shearlets are mathematically optimal for a simplified model of natural images and have been proven to be more efficient than classical systems such as wavelets. Data is acquired with a 3D Radial Phase Encoding (RPE) trajectory and an iterative reweighting scheme is used during image reconstruction to ensure fast convergence and high image quality. In our in-vivo cardiac MRI experiments we show that the proposed method 3DShearCS has lower relative errors and higher structural similarity compared to the other reconstruction techniques especially for high undersampling factors, i.e. short scan times. In this paper, we further show that 3DShearCS provides improved depiction of cardiac anatomy (measured by assessing the sharpness of coronary arteries) and two clinical experts qualitatively analyzed the image quality.Keywords
All Related Versions
This publication has 25 references indexed in Scilit:
- Accelerated motion corrected three‐dimensional abdominal MRI using total variation regularized SENSE reconstructionMagnetic Resonance in Medicine, 2015
- Whole‐heart coronary MRA with 100% respiratory gating efficiency: Self‐navigated three‐dimensional retrospective image‐based motion correction (TRIM)Magnetic Resonance in Medicine, 2013
- Introduction to Shearlets2012
- Highly efficient whole‐heart imaging using radial phase encoding‐phase ordering with automatic window selectionMagnetic Resonance in Medicine, 2011
- Whole‐heart imaging using undersampled radial phase encoding (RPE) and iterative sensitivity encoding (SENSE) reconstructionMagnetic Resonance in Medicine, 2009
- New tight frames of curvelets and optimal representations of objects with piecewise C2 singularitiesCommunications on Pure and Applied Mathematics, 2003
- “Soap‐Bubble” visualization and quantitative analysis of 3D coronary magnetic resonance angiogramsMagnetic Resonance in Medicine, 2002
- Generalized autocalibrating partially parallel acquisitions (GRAPPA)Magnetic Resonance in Medicine, 2002
- Advances in sensitivity encoding with arbitrary k‐space trajectoriesMagnetic Resonance in Medicine, 2001
- Simultaneous acquisition of spatial harmonics (SMASH): Fast imaging with radiofrequency coil arraysMagnetic Resonance in Medicine, 1997