Design and Implementation of a High-Field NdFeB Magnet System for Investigating the Spin Seebeck Effect
Authors:
- Theeranuch NachaithongTNTheeranuch Nachaithong
- Chalothon WongjomCWChalothon Wongjom
- Benjarong SamransuksamerBSBenjarong Samransuksamer
- Santi PhumyingSPSanti Phumying
- Ekkarat PongophasEPEkkarat Pongophas
- Wasan MaiaugreeWMWasan Maiaugree
- Wanchai PijitrojanaWPWanchai Pijitrojana
- Mati HorprathumMati Horprathum
- Chanunthorn ChananonnawathornCCChanunthorn Chananonnawathorn
- Supree PinitsoontornSPSupree Pinitsoontorn
- Pairot MoontragoonPMPairot Moontragoon
- Harihara RamamoorthyHRHarihara Ramamoorthy
- 25 February 2025
- journal article
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Abstract
The generation of pure spin current through thermal gradients, known as the spin Seebeck effect (SSE), has garnered significant interest in spintronics. In this study, we design and construct a permanent magnetic instrument (PMI) setup to generate a variable external magnetic field using NdFeB permanent magnets to observe the SSE. The experimental setup is composed of three crucial components: the magnetic field, the temperature gradient, and electronic control systems. Si/YIG/Pt and Si/Ni samples, prepared via sputtering techniques, were utilized for standard calibration purposes. The results show that the external magnetic field produced by NdFeB varies with the gap distance between the two magnetic poles, following an exponential decrease in field strength with increasing gap distance. The magnetic field at the center can be adjusted from ±20 Oe to ±5,000 Oe. The temperature gradient stabilizes after approximately 10 minutes, with a temperature difference (ΔT) between the heated and cooled sides ranging from 0K to 30K. For instrument testing, we performed magnetic field and angle-dependent measurements on Si/YIG/Pt and Si/Ni samples. The results indicate that the magnetic field dependence of the PMI does not exhibit the voltage loop switching seen with an alternative magnetic coil (AMC) but shows analogous behavior at high magnetic fields. Moreover, the angle dependence of both PMI and AMC yielded comparable results. In conclusion, our PMI setup procedures effectively facilitates the observation of the spin Seebeck effect.Keywords
Funding Information
- National Science, Research and Innovation Fund (NSRF) via the Program Management Unit for Human Resources and Institutional Development, Research and Innovation (B39G670018, B13F670064)
- Thammasat Postdoctoral Fellowship (TUPD23/2566)
- Research by King Mongkut’s Institute of Technology Ladkrabang (KMITL) through NSRF (RE-KRIS/FF68/25)
This publication has 27 references indexed in Scilit:
- Spin Seebeck Effect in Iron Oxide Thin Films: Effects of Phase Transition, Phase Coexistence, And Surface MagnetismACS Applied Materials & Interfaces, 2022
- Observation of nuclear-spin Seebeck effectNature Communications, 2021
- Thickness dependence of transverse thermoelectric voltage in Co40Fe60/YIG magnetic junctionsJournal of Magnetism and Magnetic Materials, 2019
- Tens of micron-thick, crack-free yttrium iron garnet films on a Gd3Ga5O12 substrate based on the layer by layer growth methodJournal of Materials Science: Materials in Electronics, 2018
- Anomalous reversal of transverse thermoelectric voltage in /YIG junctionJournal of Magnetism and Magnetic Materials, 2018
- Longitudinal spin Seebeck coefficient: heat flux vs. temperature difference methodScientific Reports, 2017
- Spin caloritronicsEnergy & Environmental Science, 2014
- Spin caloritronicsNature Materials, 2012
- Observation of the spin Seebeck effectNature, 2008
- Conversion of spin current into charge current at room temperature: Inverse spin-Hall effectApplied Physics Letters, 2006