Theeranuch Nachaithong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Theeranuch Nachaithong has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Kafizas
Department of Chemistry Imperial College London Molecular Sciences Research Hub White City Campus London UK
1 shared publication Aphiwat Pankaew
1 shared publication- Arreerat Jiamprasertboon
Functional Materials and Nanotechnology Center of Excellence, School of Science, Walailak University, Thasala, Nakhon Si Thammarat 80160, Thailand
1 shared publication - Benjarong Samransuksamer
Division of Physics, Faculty of Science and Technology, Thammasat University, Pathum Thani, Thailand
1 shared publication - Chalothon Wongjom
Division of Physics, Faculty of Science and Technology, Thammasat University, Pathum Thani, Thailand
1 shared publication - Chanunthorn Chananonnawathorn
National Electronics and Computer Technology Center, Pathum Thani, Thailand
1 shared publication
Latest Publications
- 25 September 2026
- Published by Elsevier in Surfaces and Interfaces
- Vol. 99
Direct access to aqueous WSe2 nanoflakes via rotary evaporation for adsorption and photocatalytic degradation of cationic dyes
- 25 September 2026
- Published by Elsevier in Surfaces and Interfaces
- Vol. 99
Direct access to aqueous WSe2 nanoflakes via rotary evaporation for adsorption and photocatalytic degradation of cationic dyes
- 25 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Design and Implementation of a High-Field NdFeB Magnet System for Investigating the Spin Seebeck Effect
The generation of pure spin current through thermal gradients, known as the spin Seebeck effect (SSE), has garnered significant interest in spintronics. In this study, we design and construct a permanent magnetic instrument (PMI) setup to generate a variable external magnetic field using NdFeB permanent magnets to observe the SSE. The experimental setup is composed of three crucial components: the magnetic field, the temperature gradient, and electronic control systems. Si/YIG/Pt and Si/Ni samples, prepared via sputtering techniques, were utilized for standard calibration purposes. The results show that the external magnetic field produced by NdFeB varies with the gap distance between the two magnetic poles, following an exponential decrease in field strength with increasing gap distance. The magnetic field at the center can be adjusted from ±20 Oe to ±5,000 Oe. The temperature gradient stabilizes after approximately 10 minutes, with a temperature difference (ΔT) between the heated and cooled sides ranging from 0K to 30K. For instrument testing, we performed magnetic field and angle-dependent measurements on Si/YIG/Pt and Si/Ni samples. The results indicate that the magnetic field dependence of the PMI does not exhibit the voltage loop switching seen with an alternative magnetic coil (AMC) but shows analogous behavior at high magnetic fields. Moreover, the angle dependence of both PMI and AMC yielded comparable results. In conclusion, our PMI setup procedures effectively facilitates the observation of the spin Seebeck effect.
- 25 February 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Instrumentation and Measurement
- Vol. 74 (00189456) , 1-10
Design and Implementation of a High-Field NdFeB Magnet System for Investigating the Spin Seebeck Effect
The generation of pure spin current through thermal gradients, known as the spin Seebeck effect (SSE), has garnered significant interest in spintronics. In this study, we design and construct a permanent magnetic instrument (PMI) setup to generate a variable external magnetic field using NdFeB permanent magnets to observe the SSE. The experimental setup is composed of three crucial components: the magnetic field, the temperature gradient, and electronic control systems. Si/YIG/Pt and Si/Ni samples, prepared via sputtering techniques, were utilized for standard calibration purposes. The results show that the external magnetic field produced by NdFeB varies with the gap distance between the two magnetic poles, following an exponential decrease in field strength with increasing gap distance. The magnetic field at the center can be adjusted from ±20 Oe to ±5,000 Oe. The temperature gradient stabilizes after approximately 10 minutes, with a temperature difference (ΔT) between the heated and cooled sides ranging from 0K to 30K. For instrument testing, we performed magnetic field and angle-dependent measurements on Si/YIG/Pt and Si/Ni samples. The results indicate that the magnetic field dependence of the PMI does not exhibit the voltage loop switching seen with an alternative magnetic coil (AMC) but shows analogous behavior at high magnetic fields. Moreover, the angle dependence of both PMI and AMC yielded comparable results. In conclusion, our PMI setup procedures effectively facilitates the observation of the spin Seebeck effect.