Isotopic delta values of molybdenum standard reference and prepared solutions measured by MC-ICP-MS: Proposition for delta zero and secondary references
- 4 February 2010
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 25 (5) , 716-721
Abstract
We report the isotopic composition of five molybdenum (Mo) standard reference solutions and four fractions from one of these solutions eluted through anion resin column relative to a sixth reference solution. The reference solutions were National Institute of Standards and Technology (NIST) SRM 3134 (lot#891307), Johnson Matthey Specpure (JMC)-Mo Sie (lot #602332B), JMC-Mo Wen (lot#13989C), Merck (lot#170334), Sigma-Aldrich (lot#207306) and Prolabo. Measurements were conducted using Isoprobe multi collector inductively coupled plasma mass spectrometer (MC-ICP-MS) at the Centre de Recherches Pétrographiques et Géochimiques (France) and Nu Plasma MC-ICP-MS at either the Ecole Normale Supérieure de Lyon (France) or the Laboratory of Isotope Geology in the Ministry of Land and Resources (China). The sample-standard bracketing method was employed to correct the mass bias for Mo isotopes during instrumental measurement. Except for the Merck Mo solution, all the Mo solutions were identical in isotopic composition within error. Although the JMC Mo solution has been used as the internal reference material by various groups, uncertainty may still occur with different lot numbers and availability might be limited. Here, we propose the NIST 3134 Mo solution as a new candidate for delta zero reference material, used for reporting Mo isotopic composition of natural samples. Isotopic compositions for four eluted fractions of the Sigma-Aldrich Mo solution were 2.18‰, 0.98‰, −1.10‰ and −1.95‰ for δ97/ 95Mo relative to the NIST Mo standard. These values span the range of reported isotopic compositions for natural terrestrial and experimental samples (approximately −0.5‰ to 1.6‰ for δ97/ 95Mo). We propose these eluted fractions to be used as a secondary reference for Mo isotope measurements. Mo solutions are available at CRPG upon request.Keywords
This publication has 22 references indexed in Scilit:
- Scaling NIST SRM 3149 for Se isotope analysis and isotopic variations of natural samplesChemical Geology, 2007
- Molybdenum isotope signatures in continental margin marine sedimentsEarth and Planetary Science Letters, 2006
- Molybdenum Isotope Evidence for Widespread Anoxia in Mid-Proterozoic OceansScience, 2004
- Overview and General ConceptsReviews in Mineralogy and Geochemistry, 2004
- Molybdenum isotope fractionation during adsorption by manganese oxidesEarth and Planetary Science Letters, 2004
- Molybdenum isotope records as a potential new proxy for paleoceanographyEarth and Planetary Science Letters, 2003
- Oceanic molybdenum isotope fractionation: Diagenesis and hydrothermal ridge‐flank alterationGeochemistry, Geophysics, Geosystems, 2002
- Natural mass-dependent variations in the isotopic composition of molybdenumEarth and Planetary Science Letters, 2001
- Determination of molybdenum isotope fractionation by double‐spike multicollector inductively coupled plasma mass spectrometryGeochemistry, Geophysics, Geosystems, 2001
- Determination of natural Cu-isotope variation by plasma-source mass spectrometry: implications for use as geochemical tracersChemical Geology, 2000