JCJean Carignan

Jean Carignan

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jean Carignan has a total of 25 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Isotopic delta values of molybdenum standard reference and prepared solutions measured by MC-ICP-MS: Proposition for delta zero and secondary references

    by Hanjie Wen, Jean Carignan, Christophe Cloquet, Xiangkun Zhu, Yuxu Zhang

    We report the isotopic composition of five molybdenum (Mo) standard reference solutions and four fractions from one of these solutions eluted through anion resin column relative to a sixth reference solution. The reference solutions were National Institute of Standards and Technology (NIST) SRM 3134 (lot#891307), Johnson Matthey Specpure (JMC)-Mo Sie (lot #602332B), JMC-Mo Wen (lot#13989C), Merck (lot#170334), Sigma-Aldrich (lot#207306) and Prolabo. Measurements were conducted using Isoprobe multi collector inductively coupled plasma mass spectrometer (MC-ICP-MS) at the Centre de Recherches Pétrographiques et Géochimiques (France) and Nu Plasma MC-ICP-MS at either the Ecole Normale Supérieure de Lyon (France) or the Laboratory of Isotope Geology in the Ministry of Land and Resources (China). The sample-standard bracketing method was employed to correct the mass bias for Mo isotopes during instrumental measurement. Except for the Merck Mo solution, all the Mo solutions were identical in isotopic composition within error. Although the JMC Mo solution has been used as the internal reference material by various groups, uncertainty may still occur with different lot numbers and availability might be limited. Here, we propose the NIST 3134 Mo solution as a new candidate for delta zero reference material, used for reporting Mo isotopic composition of natural samples. Isotopic compositions for four eluted fractions of the Sigma-Aldrich Mo solution were 2.18‰, 0.98‰, −1.10‰ and −1.95‰ for δ97/ 95Mo relative to the NIST Mo standard. These values span the range of reported isotopic compositions for natural terrestrial and experimental samples (approximately −0.5‰ to 1.6‰ for δ97/ 95Mo). We propose these eluted fractions to be used as a secondary reference for Mo isotope measurements. Mo solutions are available at CRPG upon request.


  • Odd Isotope Deficits in Atmospheric Hg Measured in Lichens

    by Jean Carignan, Nicolas Estrade, Jeroen E. Sonke, Olivier F.X. Donard

    Redox reactions govern mercury (Hg) concentrations in the atmosphere because fluxes (emissions and deposition), and residence times, are largely controlled by Hg speciation. Recent work on aquatic Hg photoreduction suggested that this reaction produces non-mass dependent fractionation (NMF) and that residual aquatic Hg(II) is characterized by positive Δ199Hg and Δ201Hg anomalies. Here, we show that atmospheric Hg accumulated in lichens is characterized by NMF with negative Δ199Hg and Δ201Hg values (−0.3 to −1‰), making the atmosphere and the aquatic environment complementary reservoirs regarding photoreduction and NMF of Hg isotopes. Because few other reactions than aquatic Hg photoreduction induce NMF, photochemical reduction appears to be a key pathway in the global Hg cycle. Based on a NMF isotope mass balance, direct anthropogenic emissions may account for only 50 ± 10% of atmospheric Hg deposition in an urban area of NE France. Furthermore, isotopic anomalies found in several polluted soils and sediments strongly suggests that an important part of Hg in these samples was affected by photoreactions and has cycled through the atmosphere before being stored in the geological environment. Thus, mercury isotopic anomalies measured in environmental samples may be used to trace and quantify the contribution of source emissions.


  • Lead Isotopic Composition of Fly Ash and Flue Gas Residues from Municipal Solid Waste Combustors in France: Implications for Atmospheric Lead Source Tracing

    by Jean Carignan, Guy Libourel, Christophe Cloquet, Lydie Le Forestier

    Fly ash and flue gas residues from eight municipal solid waste combustors (MSWC) in France (1992−93 and 1998/2002) were analyzed for their Pb isotopic composition. Fly ashes are more representative of solid residual particles, whereas flue gas residues reflect mostly the composition of gas phases. Both sample types contain hundreds to thousands of micrograms of metals per gram. Leaching experiments showed that metals are present in condensed phases, probably as sulfates and chlorides, and suggest that Cd, Pb, and Zn are highly fractionated from one another during volatilization/condensation processes occurring during combustion. Although all the samples analyzed define a fairly restricted range in Pb isotopic compositions (206Pb/207Pb = 1.148−1.158 and 208Pb/206Pb = 2.101−2.114) compared to other environmental samples, some MSWC produce materials having distinct isotopic compositions, whereas others display very similar ones. Isotopic heterogeneity is also measured between samples from a single MSWC. This is interpreted as resulting from the heterogeneity of the waste source materials. The range of Pb isotopic composition of incinerator materials form a well-defined linear array in the 208Pb/206Pb versus 206Pb/207Pb diagram. This array is compatible with the previously reported European standard pollution (ESP) line and most probably represent the average lead isotopic composition of industrial atmospheric emissions in France, with the following ratios: 206Pb/207Pb = 1.154 ± 0.003 and 208Pb/206Pb = 2.107 ± 0.003 (1σ).


  • A Reflection on Mg, Cd, Ca, Li and Si Isotopic Measurements and Related Reference Materials

    by Jean Carignan, Damien Cardinal, Anton Eisenhauer, Albert Galy, Mark Rehkamper, Frank Wombacher, Nathalie Vigier


  • Top Cited Papers

    Routine Analyses of Trace Elements in Geological Samples using Flow Injection and Low Pressure On‐Line Liquid Chromatography Coupled to ICP‐MS: A Study of Geochemical Reference Materials BR, DR‐N, UB‐N, AN‐G and GH

    by Jean Carignan, Pascal Hild, Guy Mevelle, Jacques Morel, Delphine Yeghicheyan

    We describe analytical procedures for trace element determinations developed at the CNRS Service d'Analyse des Roches et des Minéraux (SARM) and report results obtained for five geochemical reference materials: basalt BR, diorite DR‐N, serpentinite UB‐N, anorthosite AN‐G and granite GH. Results for rare earth elements, U and Th are also reported for other reference materials including dunite DTS‐1, peridotite PCC‐1 and basalt BIR‐1. All rocks were decomposed using alkali fusion. Analyses were done by flow injection ICP‐MS and by on‐line low pressure liquid chromatography (LC)‐ICP‐MS for samples containing very low REE, U and Th concentrations. This latter method yielded limits of determination much lower than data by direct introduction and eliminated possible isobaric interference on these elements. Although results agree with most of the working values, when available, results for some elements differed slightly from the recommended concentrations. In these cases, we propose new values for Co, Y and Zn in basalt BR, Zr in diorite DR‐N, Sr and U in granite GH, and Ga and Y in anorthosite AN‐G. Furthermore, although the Sb concentration measured in AN‐G was very close to our limit of determination, our value (0.3 ± 0.1 μg g−1) is much lower than the reported working value of 1.4 ± 0.2 μg g−1. These new values would need to be confirmed by a new inter‐laboratory programme to further characterise these reference materials.Results obtained for REE, Th and U concentrations using the on‐line low pressure LC‐ICP‐MS yielded good limits of determination (ng g−1to sub‐ng g−1for rocks and ng l−1to sub‐ng l−1for natural waters) and accurate results. The efficiency of the matrix separation allowed accurate measurements of Eu without the need to correct the BaO isobaric interference for samples having Ba/Eu ratios as high as 27700. For REE concentrations in PCC‐1 and DTS‐1, differences with values reported in the literature are interpreted as resulting from possible heterogeneity of the reference materials. Thorium and U values are proposed for these two samples, as well as for AN‐G and UB‐N.