Improving esophageal protection during AF ablation: The IMPACT study
Authors:
- Lisa Wm LeungLLLisa Wm Leung
- Abhay BajpaiABAbhay Bajpai
- Zia ZuberiZZZia Zuberi
- Anthony LiALAnthony Li
- Mark NormanMNMark Norman
- Riyaz KabaRKRiyaz Kaba
- Zaki AkhtarZAZaki Akhtar
- Banu EvranosBEBanu Evranos
- Hanney GonnaHGHanney Gonna
- Idris HardingIHIdris Harding
- Manav SohalMSManav Sohal
- Nawaf Al-SubaieNANawaf Al-Subaie
Preprint
Abstract
Background: Thermal injury to the esophagus is a known complication of ablation for atrial fibrillation (AF) and accounts for most procedure-related mortality. Thermal protection of the esophageal lumen by infusing cold liquid can reduce thermal injury to a limited extent. A method to control the local luminal esophageal temperature is investigated by this study. Objective: To investigate the ability of a powerful temperature control device to protect the esophagus from ablation-related thermal injury. Methods: A single-center, prospective, double-blinded randomized controlled trial was used to investigate the ability of the ensoETM device to protect the esophagus from thermal injury. This method was compared in a 1:1 randomization to a control group of standard practice utilizing a single-point temperature probe. In the study group, the device was used to keep the luminal temperature at 4°C during radiofrequency (RF) ablation for AF. Endoscopic examination was performed at 7 days post-ablation and esophageal injury was scored. The patient and the endoscopist were blinded to the randomization. Results: We recruited 188 patients, of whom 120 underwent endoscopy. Thermal injury to the mucosa was significantly more common in the control group than in those receiving esophageal protection (12/60 versus 2/60; P=0.008), with a trend toward reduction in gastroparesis (6/60 Vs 2/60, p=0.27). There was no difference between groups in RF duration, force, power and combined ablation index (P value range= 0.2-0.9). Procedure duration and fluoroscopy duration were similar (P=0.97, P=0.91 respectively). Conclusion: Thermal protection of the esophageal lumen significantly reduces ablation-related thermal injury compared to standard care. This method of esophageal protection is safe and does not compromise the efficacy of the ablation procedure. CONDENSED Thermal injury to the esophagus causes most ablation-related deaths. We investigated the ability of a powerful method of esophageal temperature control to protect from thermal lesions during ablation, using a double-blinded randomized clinical trial to compare this to standard care. Patients randomised to receive thermal protection experienced significantly fewer lesions to the esophageal mucosa and a trend towards reduction in gastroparesis. Procedure efficacy and efficiency were not compromised.Keywords
All Related Versions
- Published version: EP Europace, 23 (2), 205.
This publication has 19 references indexed in Scilit:
- Esophageal Temperature Management in Patients Suffering from Traumatic Brain InjuryTherapeutic Hypothermia and Temperature Management, 2019
- Temporal relationships between esophageal injury type and progression in patients undergoing atrial fibrillation catheter ablationHeart Rhythm, 2019
- Esophageal Injury and Atrioesophageal Fistula Caused by Ablation for Atrial FibrillationCirculation, 2017
- Upper gastrointestinal complications following ablation therapy for atrial fibrillationNeurogastroenterology & Motility, 2017
- The esophageal cooling device: A new temperature control tool in the intensivist's arsenalHeart & Lung, 2017
- Esophagus‐Related Complications During Second‐Generation Cryoballoon Ablation—Insight from Simultaneous Esophageal Temperature Monitoring from 2 Esophageal ProbesJournal of Cardiovascular Electrophysiology, 2016
- Effect of Atrial Fibrillation Ablation on Gastric MotilityCirculation: Arrhythmia and Electrophysiology, 2015
- Esophageal Capsule Endoscopy After Radiofrequency Catheter Ablation for Atrial FibrillationCirculation: Arrhythmia and Electrophysiology, 2009
- Incidence of oesophageal wall injury post-pulmonary vein antrum isolation for treatment of patients with atrial fibrillationEP Europace, 2008
- Esophageal perforation during left atrial radiofrequency ablation: Is the risk too high?The Journal of Thoracic and Cardiovascular Surgery, 2003