Manav Sohal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Manav Sohal has a total of 56 co-authors. Here are the top co-authors by number of shared publications:
- Lisa W. M. Leung
St George’s Hospital, London SW17 0QT, UK
3 shared publications - Mark Michael Gallagher
Department of Cardiology St. George's University Hospitals NHS Foundation Trust London UK
3 shared publications - Ravi Kamdar
Croydon University Hospital, London, United Kingdom
2 shared publications - Zaki Akhtar
Department of Cardiology St. George's University Hospitals NHS Foundation Trust London UK
2 shared publications - Abhay Bajpai
St. George's NHS Foundation Trust
1 shared publication - Anthony Li
St. George's NHS Foundation Trust
1 shared publication
Latest Publications
- Open Access
- 24 May 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (Supplement)
One-year freedom from arrhythmia following radiofrequency ablation using proactive oesophageal cooling
Background: Proactive esophageal cooling is increasingly being utilized, and is now FDA cleared, to reduce the likelihood of ablation-related esophageal injury resulting from radiofrequency (RF) cardiac ablation of atrial fibrillation (AF). One-year follow-up from the largest randomized controlled study, the IMPACT trial, showed a trend towards improvement in long-term efficacy versus luminal esophageal temperature (LET) monitoring. With larger data sets now available for analysis, we sought to determine 1-year freedom from atrial arrhythmia associated with the use of proactive esophageal cooling. Methods: Data from 2 trials comparing freedom from atrial arrhythmia after RF ablation using proactive esophageal cooling to LET monitoring were combined. Data were analyzed using a stratified Cox proportional hazards model to compare arrhythmia recurrence rates, with R statistical analysis software. Results: Data from 631 patients across two studies comparing arrhythmia outcomes for proactive oesophageal cooling versus LET monitoring were analysed. Mean patient age was 66.4±9.8 years, and 37.4% were female. Arrhythmias were 56.3% paroxysmal AF and 43.7% persistent or long-standing persistent AF. Freedom from atrial arrhythmia at one year was 77.2% for patients receiving proactive oesophageal cooling and 64.4% for patients receiving LET monitoring (Figure 1), with a hazard ratio for cooling of 0.65 (95% CI 0.43 to 0.99, P = 0.044). Conclusions: Proactive oesophageal cooling was associated with significantly greater freedom from atrial arrhythmia at one year when compared to LET monitoring during RF ablation.
- 24 May 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (Supplement)
Open AccessOne-year freedom from arrhythmia following radiofrequency ablation using proactive oesophageal cooling
Background: Proactive esophageal cooling is increasingly being utilized, and is now FDA cleared, to reduce the likelihood of ablation-related esophageal injury resulting from radiofrequency (RF) cardiac ablation of atrial fibrillation (AF). One-year follow-up from the largest randomized controlled study, the IMPACT trial, showed a trend towards improvement in long-term efficacy versus luminal esophageal temperature (LET) monitoring. With larger data sets now available for analysis, we sought to determine 1-year freedom from atrial arrhythmia associated with the use of proactive esophageal cooling. Methods: Data from 2 trials comparing freedom from atrial arrhythmia after RF ablation using proactive esophageal cooling to LET monitoring were combined. Data were analyzed using a stratified Cox proportional hazards model to compare arrhythmia recurrence rates, with R statistical analysis software. Results: Data from 631 patients across two studies comparing arrhythmia outcomes for proactive oesophageal cooling versus LET monitoring were analysed. Mean patient age was 66.4±9.8 years, and 37.4% were female. Arrhythmias were 56.3% paroxysmal AF and 43.7% persistent or long-standing persistent AF. Freedom from atrial arrhythmia at one year was 77.2% for patients receiving proactive oesophageal cooling and 64.4% for patients receiving LET monitoring (Figure 1), with a hazard ratio for cooling of 0.65 (95% CI 0.43 to 0.99, P = 0.044). Conclusions: Proactive oesophageal cooling was associated with significantly greater freedom from atrial arrhythmia at one year when compared to LET monitoring during RF ablation.
- Open Access
- 17 October 2023
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 10 (10) , 428
Progress in Cardiac Resynchronisation Therapy and Optimisation
Cardiac resynchronisation therapy (CRT) has become the cornerstone of heart failure (HF) treatment. Despite the obvious benefit from this therapy, an estimated 30% of CRT patients do not respond (“non-responders”). The cause of “non-response” is multi-factorial and includes suboptimal device settings. To optimise CRT settings, echocardiography has been considered the gold standard but has limitations: it is user dependent and consumes time and resources. CRT proprietary algorithms have been developed to perform device optimisation efficiently and with limited resources. In this review, we discuss CRT optimisation including the various adopted proprietary algorithms and conduction system pacing.
- 17 October 2023
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 10 (10) , 428
Open AccessProgress in Cardiac Resynchronisation Therapy and Optimisation
Cardiac resynchronisation therapy (CRT) has become the cornerstone of heart failure (HF) treatment. Despite the obvious benefit from this therapy, an estimated 30% of CRT patients do not respond (“non-responders”). The cause of “non-response” is multi-factorial and includes suboptimal device settings. To optimise CRT settings, echocardiography has been considered the gold standard but has limitations: it is user dependent and consumes time and resources. CRT proprietary algorithms have been developed to perform device optimisation efficiently and with limited resources. In this review, we discuss CRT optimisation including the various adopted proprietary algorithms and conduction system pacing.
- Open Access
- 1 February 2021
- Published by Elsevier in Heart Rhythm O2
- Vol. 2 (1) , 19-27
A multicenter prospective randomized controlled trial of cardiac resynchronization therapy guided by invasive dP/dt
- 1 February 2021
- Published by Elsevier in Heart Rhythm O2
- Vol. 2 (1) , 19-27
Open AccessA multicenter prospective randomized controlled trial of cardiac resynchronization therapy guided by invasive dP/dt
- 1 January 2021
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 14 (1) , e008932
Remote Monitoring of Arrhythmias in the COVID Lockdown Era
- 1 January 2021
- Published by Wolters Kluwer Health in Circulation: Arrhythmia and Electrophysiology
- Vol. 14 (1) , e008932
Remote Monitoring of Arrhythmias in the COVID Lockdown Era
- Open Access
Improving esophageal protection during AF ablation: The IMPACT study
Background: Thermal injury to the esophagus is a known complication of ablation for atrial fibrillation (AF) and accounts for most procedure-related mortality. Thermal protection of the esophageal lumen by infusing cold liquid can reduce thermal injury to a limited extent. A method to control the local luminal esophageal temperature is investigated by this study. Objective: To investigate the ability of a powerful temperature control device to protect the esophagus from ablation-related thermal injury. Methods: A single-center, prospective, double-blinded randomized controlled trial was used to investigate the ability of the ensoETM device to protect the esophagus from thermal injury. This method was compared in a 1:1 randomization to a control group of standard practice utilizing a single-point temperature probe. In the study group, the device was used to keep the luminal temperature at 4°C during radiofrequency (RF) ablation for AF. Endoscopic examination was performed at 7 days post-ablation and esophageal injury was scored. The patient and the endoscopist were blinded to the randomization. Results: We recruited 188 patients, of whom 120 underwent endoscopy. Thermal injury to the mucosa was significantly more common in the control group than in those receiving esophageal protection (12/60 versus 2/60; P=0.008), with a trend toward reduction in gastroparesis (6/60 Vs 2/60, p=0.27). There was no difference between groups in RF duration, force, power and combined ablation index (P value range= 0.2-0.9). Procedure duration and fluoroscopy duration were similar (P=0.97, P=0.91 respectively). Conclusion: Thermal protection of the esophageal lumen significantly reduces ablation-related thermal injury compared to standard care. This method of esophageal protection is safe and does not compromise the efficacy of the ablation procedure. CONDENSED Thermal injury to the esophagus causes most ablation-related deaths. We investigated the ability of a powerful method of esophageal temperature control to protect from thermal lesions during ablation, using a double-blinded randomized clinical trial to compare this to standard care. Patients randomised to receive thermal protection experienced significantly fewer lesions to the esophageal mucosa and a trend towards reduction in gastroparesis. Procedure efficacy and efficiency were not compromised.
Open AccessImproving esophageal protection during AF ablation: The IMPACT study
Background: Thermal injury to the esophagus is a known complication of ablation for atrial fibrillation (AF) and accounts for most procedure-related mortality. Thermal protection of the esophageal lumen by infusing cold liquid can reduce thermal injury to a limited extent. A method to control the local luminal esophageal temperature is investigated by this study. Objective: To investigate the ability of a powerful temperature control device to protect the esophagus from ablation-related thermal injury. Methods: A single-center, prospective, double-blinded randomized controlled trial was used to investigate the ability of the ensoETM device to protect the esophagus from thermal injury. This method was compared in a 1:1 randomization to a control group of standard practice utilizing a single-point temperature probe. In the study group, the device was used to keep the luminal temperature at 4°C during radiofrequency (RF) ablation for AF. Endoscopic examination was performed at 7 days post-ablation and esophageal injury was scored. The patient and the endoscopist were blinded to the randomization. Results: We recruited 188 patients, of whom 120 underwent endoscopy. Thermal injury to the mucosa was significantly more common in the control group than in those receiving esophageal protection (12/60 versus 2/60; P=0.008), with a trend toward reduction in gastroparesis (6/60 Vs 2/60, p=0.27). There was no difference between groups in RF duration, force, power and combined ablation index (P value range= 0.2-0.9). Procedure duration and fluoroscopy duration were similar (P=0.97, P=0.91 respectively). Conclusion: Thermal protection of the esophageal lumen significantly reduces ablation-related thermal injury compared to standard care. This method of esophageal protection is safe and does not compromise the efficacy of the ablation procedure. CONDENSED Thermal injury to the esophagus causes most ablation-related deaths. We investigated the ability of a powerful method of esophageal temperature control to protect from thermal lesions during ablation, using a double-blinded randomized clinical trial to compare this to standard care. Patients randomised to receive thermal protection experienced significantly fewer lesions to the esophageal mucosa and a trend towards reduction in gastroparesis. Procedure efficacy and efficiency were not compromised.
- 1 January 2017
- Published by Radcliffe Medical Media Ltd in European Cardiology Review
- Vol. 12 (1) , 38-39
Contemporary Management of Stroke Prevention in Atrial Fibrillation Following the European Society of Cardiology Guidelines
The recent publication of the European Society of Cardiology (ESC) guidelines for the management of atrial fibrillation provides a timely update at a time when the rapid uptake of non-vitamin K antagonist oral anticoagulants has changed the landscape of clinical practice. Several key changes have been highlighted, including better identification of those deemed to be low risk for thromboembolic complications and a more standardised approach to patients with atrial fibrillation who require concomitant antiplatelet therapy following either percutaneous coronary intervention or an acute coronary syndrome. This article distils the key messages from the ESC guidelines and draws the reader’s attention to both gaps and advances in our knowledge.
- 1 January 2017
- Published by Radcliffe Medical Media Ltd in European Cardiology Review
- Vol. 12 (1) , 38-39
Contemporary Management of Stroke Prevention in Atrial Fibrillation Following the European Society of Cardiology Guidelines
The recent publication of the European Society of Cardiology (ESC) guidelines for the management of atrial fibrillation provides a timely update at a time when the rapid uptake of non-vitamin K antagonist oral anticoagulants has changed the landscape of clinical practice. Several key changes have been highlighted, including better identification of those deemed to be low risk for thromboembolic complications and a more standardised approach to patients with atrial fibrillation who require concomitant antiplatelet therapy following either percutaneous coronary intervention or an acute coronary syndrome. This article distils the key messages from the ESC guidelines and draws the reader’s attention to both gaps and advances in our knowledge.