A conceptual study on real-time adaptive radiation therapy optimization through ultra-fast beamlet control
Preprint
Abstract
A central problem in the field of radiation therapy (RT) is how to optimally deliver dose to a patient in a way that fully accounts for anatomical position changes over time. As current RT is a static process, where beam intensities are calculated before the start of treatment, anatomical deviations can result in poor dose conformity. To overcome these limitations, we present a simulation study on a fully dynamic real-time adaptive radiation therapy (RT-ART) optimization approach that uses ultra-fast beamlet control to dynamically adapt to patient motion in real-time. A virtual RT-ART machine was simulated with a rapidly rotating linear accelerator (LINAC) source (60 RPM) and a binary 1D multi-leaf collimator (MLC) operating at 100 Hz. If the real-time tracked target motion exceeded a predefined threshold, a time dependent objective function was solved using fast optimization methods to calculate new beamlet intensities that were then delivered to the patient. To evaluate the approach, system response was analyzed for patient derived continuous drift, step-like, and periodic intra-fractional motion. For each motion type investigated, the RT-ART method was compared against the ideal case with no patient motion (static case) as well as to the case without the use RT-ART. In all cases, isodose lines and dose-volume-histograms (DVH) showed that RT-ART plan quality was approximately the same as the static case, and considerably better than the no RT-ART case. The RT-ART optimization framework has the potential to optimally deliver dose to a patient in a way that fully accounts for anatomical changes due to motion. With continued advances in real-time patient motion tracking and fast computational processes, there is significant potential for the RT-ART optimization process to be realized on next generation RT machines.Keywords
All Related Versions
This publication has 33 references indexed in Scilit:
- Real-time energy/mass transfer mapping for online 4D dose reconstructionScientific Reports, 2018
- Use of Proximal Operator Graph Solver for Radiation Therapy Inverse Treatment PlanningMedical Physics, 2017
- matRad - a multi-modality open source 3D treatment planning toolkit2015
- The ViewRay System: Magnetic Resonance–Guided and Controlled RadiotherapySeminars in Radiation Oncology, 2014
- Real-time dynamic MLC tracking for inversely optimized arc radiotherapyRadiotherapy and Oncology, 2010
- Large-scale nonlinear programming using IPOPT: An integrating framework for enterprise-wide dynamic optimizationComputers & Chemical Engineering, 2009
- Technical principles of dual source CTEuropean Journal of Radiology, 2008
- Conventional, conformal, and intensity-modulated radiation therapy treatment planning of external beam radiotherapy for cervical cancer: The impact of tumor regressionInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2006
- Peacock™: A system for planning and rotational delivery of intensity‐modulated fieldsInternational Journal of Imaging Systems and Technology, 1995
- Analysis of movement of intrathoracic neoplasms using ultrafast computerized tomographyInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 1990