GaitVibe+
Authors:
Open Access
- 6 November 2022
- conference paper
- Published by Association for Computing Machinery (ACM)
- p. 1168-1174
Abstract
In-home gait analysis is important for providing early diagnosis and adaptive treatments for individuals with gait disorders. Existing systems include wearables and pressure mats, but they have limited scalability due to dense deployment and device carrying/charging requirements. Recently, vision-based systems have been developed to enable scalable, accurate in-home gait analysis, but it faces privacy concerns due to the exposure of people's appearances and daily activities. To overcome these limitations, our prior work developed footstep-induced structural vibration sensing for in-home gait monitoring, which is device-free, wide-ranged, and perceived as more privacy-friendly. Although it has succeeded in temporal parameter estimation, it shows limited performance for spatial gait parameter estimation due to the low accuracy in footstep localization. In particular, the localization error mainly comes from the estimation error of the wave arrival time at the vibration sensors and its error propagation to wave velocity estimations. To this end, we present GaitVibe+, a vibration-based footstep localization method fused with temporarily installed cameras for in-home gait analysis. Our method has two stages: fusion and operating stages. In the fusion stage, both cameras and vibration sensors are installed to record only a few trials of the subject's footstep data, through which we characterize the uncertainty in wave arrival time and model the wave velocity profiles for the given structure. In the operating stage, we remove the camera to preserve privacy at home. The footstep localization is conducted by estimating the time difference of arrival (TDoA) over multiple vibration sensors, whose accuracy is improved through the reduced uncertainty and velocity modeling during the fusion stage. We evaluate GaitVibe+ through a real-world experiment with 50 walking trials. With only 3 trials of multi-modal fusion, our approach has an average localization error of 0.22 meters, which reduces the spatial gait parameter error by 4.1x (from 111.4% to 27.1%) compared to the existing work.Keywords
All Related Versions
Funding Information
- National Science Foundation (NSF-CMMI-2026699)
This publication has 16 references indexed in Scilit:
- Model-Based Occupant Tracking Using Slab-Vibration MeasurementsFrontiers in Built Environment, 2019
- Gait health monitoring through footstep-induced floor vibrations2019
- Occupant localization using footstep-induced structural vibrationMechanical Systems and Signal Processing, 2018
- A Simple Yet Effective Baseline for 3d Human Pose Estimation2017
- VNectACM Transactions on Graphics, 2017
- Multiple Pedestrian Tracking through Ambient Structural Vibration Sensing2016
- Non-intrusive Occupant Localization Using Floor Vibrations in Dispersive Structure2016
- Indoor Person Identification through Footstep Induced Structural Vibration2015
- Laboratory Review: The Role of Gait Analysis in Seniors’ Mobility and Fall PreventionGerontology, 2010
- A single gyroscope method for spatial gait analysis2010