UK greenhouse gas measurements at two new tall towers for aiding emissions verification
Open Access
- 22 August 2019
- journal article
- research article
- Published by Copernicus GmbH in Atmospheric Measurement Techniques
- Vol. 12 (8) , 4495-4518
Abstract
Under the UK-focused Greenhouse gAs and Uk and Global Emissions (GAUGE) project, two new tall tower greenhouse gas (GHG) observation sites were established in the 2013/2014 Northern Hemispheric winter. These sites, located at existing telecommunications towers, utilized a combination of cavity ring-down spectroscopy (CRDS) and gas chromatography (GC) to measure key GHGs (CO2, CH4, CO, N2O and SF6). Measurements were made at multiple intake heights on each tower. CO2 and CH4 dry mole fractions were calculated from either CRDS measurements of wet air, which were post-corrected with an instrument-specific empirical correction, or samples dried to between 0.05 % H2O and 0.3 % H2O using a Nafion® dryer, with a smaller correction applied for the residual H2O. The impact of these two drying strategies was examined. Drying with a Nafion® dryer was not found to have a significant effect on the observed CH4 mole fraction; however, Nafion® drying did cause a 0.02 µmol mol−1 CO2 bias. This bias was stable for sample CO2 mole fractions between 373 and 514 µmol mol−1 and for sample H2O up to 3.5 %. As the calibration and standard gases are treated in the same manner, the 0.02 µmol mol−1 CO2 bias is mostly calibrated out with the residual error (≪0.01 µmol mol−1 CO2) well below the World Meteorological Organization (WMO) reproducibility requirements. Of more concern was the error associated with the empirical instrument-specific water correction algorithms. These corrections are relatively stable and reproducible for samples with H2O between 0.2 % and 2.5 %, CO2 between 345 and 449 µmol mol−1, and CH4 between 1743 and 2145 nmol mol−1. However, the residual errors in these corrections increase to > 0.05 µmol mol−1 for CO2 and > 1 nmol mol−1 for CH4 (greater than the WMO internal reproducibility guidelines) at higher humidities and for samples with very low (< 0.5 %) water content. These errors also scale with the absolute magnitude of the CO2 and CH4 mole fractions. As such, water corrections calculated in this manner are not suitable for samples with low (< 0.5 %) or high (> 2.5 %) water contents and either alternative correction methods should be used or partial drying or humidification considered prior to sample analysis.Keywords
All Related Versions
This publication has 34 references indexed in Scilit:
- Improving measurements of SF6 for the study of atmospheric transport and emissionsAtmospheric Measurement Techniques, 2011
- Exploring causes of interannual variability in the seasonal cycles of tropospheric nitrous oxideAtmospheric Chemistry and Physics, 2011
- Continuous low-maintenance CO2/CH4/H2O measurements at the Zotino Tall Tower Observatory (ZOTTO) in Central SiberiaAtmospheric Measurement Techniques, 2010
- High-accuracy continuous airborne measurements of greenhouse gases (CO2 and CH4) using the cavity ring-down spectroscopy (CRDS) techniqueAtmospheric Measurement Techniques, 2010
- A single gas chromatograph for accurate atmospheric mixing ratio measurements of CO2, CH4, N2O, SF6 and COAtmospheric Measurement Techniques, 2009
- CO2 permeability in Nafion® EW1100 at elevated temperatureSolid State Ionics, 2007
- Measurements of carbon dioxide on very tall towers: results of the NOAA/CMDL programTellus B: Chemical and Physical Meteorology, 1998
- Soils as sources and sinks for atmospheric methaneCanadian Journal of Soil Science, 1997
- Testing high‐resolution nitrous oxide emission estimates against observations using an atmospheric transport modelGlobal Biogeochemical Cycles, 1996
- Drier for field use in the determination of trace atmospheric gasesAnalytical Chemistry, 1979