Microfluidic Isolation of Aptamers for Intracellular Measurement of Radio-Responsive Proteins
Open Access
Abstract
In large-scale radiological events, there is a need to triage affected individuals based on their biological absorbed dose. Biodosimetry measures biological responses in relation to the received dose. Radiation-responsive protein biomarkers in peripheral blood lymphocytes, especially intracellular proteins, have been validated for biodosimetry with immunochemical-based measurement methods. However, these antibody-based assays can suffer from stability and batch-to-batch variations. Aptamers are single-stranded oligonucleotide alternatives to antibodies that are stable and much smaller in size, making them ideal probes for intracellular targets. However, few aptamers have been developed against intracellular targets, and these efforts are especially hampered due to the time-consuming nature of the conventional aptamer selection method. An efficient method for isolating aptamers against intracellular radiation-responsive proteins is not available yet. Herein, we used a microfluidic aptamer isolation method to develop an aptamer against the intracellular radiation biomarker BAX in blood lymphocytes. The isolated aptamer has a dissociation constant of 6.95 nM against human BAX protein and a bright detail similarity score of 1.9 when colocalizing with anti-BAX aptamer intracellularly. The in situ labeling of the intracellular BAX protein also shows the aptamer can be used to differentiate 2.5 Gy or 3 Gy of radiation in ex vivo human and in vivo mouse peripheral blood samples exposed to X-rays. In conclusion, this proof-of-concept study indicates that the microfluidic-enabled aptamer isolation method could be used for the development of a panel of targeted intracellular proteins for radiation biodosimetry applications.Keywords
Funding Information
- National Institutes of Health (U19AI067773, R01GM138843, R21CA261775, R01EB032910, U01AI148309)
This publication has 48 references indexed in Scilit:
- Current developments in biodosimetry tools for radiological/nuclear mass casualty incidentsEnvironmental Advances, 2022
- Aptamer based probes for living cell intracellular molecules detectionBiosensors and Bioelectronics, 2022
- Research progress on biodosimeters of ionizing radiation damageRadiation Medicine and Protection, 2020
- Nucleic Acid Aptamers for Molecular Diagnostics and Therapeutics: Advances and PerspectivesAngewandte Chemie International Edition, 2020
- An integrated microfluidic platform to perform uninterrupted SELEX cycles to screen affinity reagents specific to cardiovascular biomarkersBiosensors and Bioelectronics, 2018
- AptaSUITE: A Full-Featured Bioinformatics Framework for the Comprehensive Analysis of Aptamers from HT-SELEX ExperimentsMolecular Therapy Nucleic Acids, 2018
- Toward the development of transcriptional biodosimetry for the identification of irradiated individuals and assessment of absorbed radiation doseRadiation and Environmental Biophysics, 2015
- Bax Crystal Structures Reveal How BH3 Domains Activate Bax and Nucleate Its Oligomerization to Induce ApoptosisCell, 2013
- Fluorescence Polarization (FP) Assays for Monitoring Peptide‐Protein or Nucleic Acid‐Protein BindingCurrent Protocols in Chemical Biology, 2009
- Mutation assay at the thymidine kinase locus in diploid human lymphoblastsMutation Research - Fundamental and Molecular Mechanisms of Mutagenesis, 1982