KWKechun Wen

Kechun Wen

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kechun Wen has a total of 11 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Optimizing Surface Functionalization for Aptameric Graphene Nanosensors in Undiluted Physiological Media

    by Wenting Dai, Ziran Wang, Shifeng Yu, Kechun Wen, Yucheng Yang, Qiao Lin

    This paper presents the optimization of surface modification for aptameric graphene nanosensors for the measurement of biomarkers in undiluted physiological media. In these sensors, graphene transduces the binding between an aptamer and the intended target biomarker into a measurable signal while being coated with a polyethylene glycol (PEG) nanolayer to minimize nonspecific adsorption of matrix molecules. We perform a systematic study of the aptamer and PEG attachment schemes and parameters, including the impact of the serial or parallel PEG–aptamer attachment scheme, PEG molecular weight and surface density, and aptamer surface density on the sensor behavior, such as the responsivity to biomarker concentration changes, and importantly, they are used for operation in physiological media and have the ability to reject nonspecific binding to interfering molecules. We then use the understanding from this parametric study to identify graphene nanosensor designs that are optimally functionalized with PEG and aptamers to be strongly responsive to target biomarkers and effectively reduce nonspecific adsorption of interferents, thereby enabling sensitive and specific biomarker measurements in undiluted physiological media. The experimental results show that nanosensors that were optimized via serial modification with 5000 Da PEG at 15 mM and a 94 nt DNA aptamer at 500 nM allowed specific measurement of C-reactive protein (CRP) in undiluted human serum with a limit of detection (LOD) down to 27 pM, representing an up to 1000-fold improvement compared to previously reported CRP measurements.


  • Open Access

    Microfluidic Isolation of Aptamers for Intracellular Measurement of Radio-Responsive Proteins

    by Xin Meng, Leah Nemzow, Yaru Han, Kechun Wen, Sally A. Amundson, Helen C. Turner, Qiao Lin

    In large-scale radiological events, there is a need to triage affected individuals based on their biological absorbed dose. Biodosimetry measures biological responses in relation to the received dose. Radiation-responsive protein biomarkers in peripheral blood lymphocytes, especially intracellular proteins, have been validated for biodosimetry with immunochemical-based measurement methods. However, these antibody-based assays can suffer from stability and batch-to-batch variations. Aptamers are single-stranded oligonucleotide alternatives to antibodies that are stable and much smaller in size, making them ideal probes for intracellular targets. However, few aptamers have been developed against intracellular targets, and these efforts are especially hampered due to the time-consuming nature of the conventional aptamer selection method. An efficient method for isolating aptamers against intracellular radiation-responsive proteins is not available yet. Herein, we used a microfluidic aptamer isolation method to develop an aptamer against the intracellular radiation biomarker BAX in blood lymphocytes. The isolated aptamer has a dissociation constant of 6.95 nM against human BAX protein and a bright detail similarity score of 1.9 when colocalizing with anti-BAX aptamer intracellularly. The in situ labeling of the intracellular BAX protein also shows the aptamer can be used to differentiate 2.5 Gy or 3 Gy of radiation in ex vivo human and in vivo mouse peripheral blood samples exposed to X-rays. In conclusion, this proof-of-concept study indicates that the microfluidic-enabled aptamer isolation method could be used for the development of a panel of targeted intracellular proteins for radiation biodosimetry applications.