Follow-up of CRT-D patients downgraded to CRT-P at the time of generator exchange
Authors:
Open Access
- 15 June 2023
- journal article
- research article
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 10, 1217523
Abstract
Background: Some patients with cardiac resynchronisation therapy (CRT) experience super-response (LVEF improvements to ≥50%). At generator exchange (GE), downgrading (DG) from CRT-defibrillator (CRT-D) to CRT-pacemaker (CRT-P) could be an option for these patients on primary prevention ICD indication and no required ICD therapies. Long-term data on arrhythmic events in super-responders is scarce.Methods: CRT-D patients with LVEF improvement to ≥50% at GE were identified in four large centres for retrospective analysis. Mortality, significant ventricular tachyarrhythmia and appropriate ICD-therapy were determined, and patient analysis was split into two groups (downgraded to CRT-P or not).Results: Sixty-six patients (53% male, 26% coronary artery disease) on primary prevention were followed for a median of 129 months [IQR: 101–155] after implantation. 27 (41%) patients were downgraded to CRT-P at GE after a median of 68 [IQR: 58–98] months (LVEF 54% ± 4%). The other 39 (59%) continued with CRT-D therapy (LVEF 52% ± 6%). No cardiac death or significant arrhythmia occurred in the CRT-P group (median follow-up (FU) 38 months [IQR: 29–53]). Three appropriate ICD-therapies occurred in the CRT-D group [median FU 70 months (IQR: 39–97)]. Annualized event-rates after DG/GE were 1.5%/year and 1.0%/year in the CRT-D group and the whole cohort, respectively.Conclusions: No significant tachyarrhythmia were detected in the patients downgraded to CRT-P during follow-up. However, three events were observed in the CRT-D group. Whilst downgrading CRT-D patients is an option, a small residual risk for arrhythmic events remains and decisions regarding downgrade should be made on a case-by-case basis.Keywords
This publication has 28 references indexed in Scilit:
- Left Ventricular Ejection Fraction Normalization in Cardiac Resynchronization Therapy and Risk of Ventricular Arrhythmias and Clinical OutcomesCirculation, 2014
- Ventricular Arrhythmias in Super-responders to Cardiac Resynchronization TherapyRevista Española de Cardiología (English Edition), 2014
- Long-term outcome of 'super-responder' patients to cardiac resynchronization therapyEP Europace, 2013
- Downgrade from CRT-D to CRT-P at the moment of device replacement, an opportunity for selective disinvestmentEuropean Heart Journal, 2013
- Normalization of Left Ventricular Ejection Fraction after Cardiac Resynchronization Therapy Also Normalizes SurvivalPacing and Clinical Electrophysiology, 2013
- Assessment of Myocardial Scarring Improves Risk Stratification in Patients Evaluated for Cardiac Defibrillator ImplantationJACC, 2012
- Predictors of Super-Response to Cardiac Resynchronization Therapy and Associated Improvement in Clinical OutcomeJACC, 2012
- Inappropriate Implantable Cardioverter-Defibrillator ShocksJACC, 2011
- Close Connection between Improvement in Left Ventricular Function by Cardiac Resynchronization Therapy and the Incidence of Arrhythmias in Cardiac Resynchronization Therapy-Defibrillator PatientsEuropean Journal of Heart Failure, 2010
- Cardiac-Resynchronization Therapy with or without an Implantable Defibrillator in Advanced Chronic Heart FailureThe New England journal of medicine, 2004