Beat Schaer
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Beat Schaer has a total of 140 co-authors. Here are the top co-authors by number of shared publications:
- Christian Sticherling
Department of Cardiology, University Hospital Basel, University Basel , Basel
14 shared publications - Michael Kühne
Department of Cardiology, University Hospital Basel , Petersgraben 4, Basel 4031
14 shared publications - Stefan Osswald
Cardiology Division, Department of Medicine, University Hospital Basel, Basel, Switzerland
7 shared publications - Tobias Reichlin
Department of Cardiology (T.R.), Inselspital, Bern University Hospital, University of Bern, Switzerland
6 shared publications Christian Sticherling
Department of Cardiology, University Hospital Basel, University Basel
5 shared publications- Patrick Badertscher
Department of Cardiology, University Hospital Basel, University of Basel , Basel
5 shared publications
Latest Publications
- Open Access
- 2 September 2026
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (9)
Sex-specific trends in ventricular arrhythmias among European implantable cardioverter-defibrillator recipients
- 2 September 2026
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (9)
Open AccessSex-specific trends in ventricular arrhythmias among European implantable cardioverter-defibrillator recipients
- Open Access
- 2 September 2026
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (9)
Prognostic value of isolated PR interval prolongation after transcatheter aortic valve implantation
- 2 September 2026
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (9)
Open AccessPrognostic value of isolated PR interval prolongation after transcatheter aortic valve implantation
- Open Access
- 2 June 2026
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (6)
Contemporary trends and outcomes in European ICD recipients: a 15-year analysis
- 2 June 2026
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 28 (6)
Open AccessContemporary trends and outcomes in European ICD recipients: a 15-year analysis
- Open Access
- 13 May 2026
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 13, 1743535
CHA2DS2-VA score for predicting ventricular arrhythmias and mortality in ICD patients with ischemic heart disease and dilated cardiomyopathy: results from a prospective cohort
Background and aims: The revised CHA 2 DS 2 -VA score facilitates stroke risk assessment in patients with atrial fibrillation. This study investigates the value of the CHA 2 DS 2 -VA for prediction of all-cause and cardiovascular mortality and ventricular arrhythmia (VA) in patients with ischemic heart disease (IHD) and dilated cardiomyopathy (DCM) undergoing implantable cardioverter-defibrillator (ICD) therapy. Methods: We analyzed data from 1,626 ICD recipients with IHD ( n = 1,225) or DCM ( n = 401) enrolled in a prospective registry at University Hospital Basel. Patients were stratified into low and high CHA 2 DS 2 -VA groups based on median score within each condition. Mortality and VA outcomes were assessed using Kaplan–Meier survival analysis and Cox proportional hazards models. Results: The median CHA 2 DS 2 -VA was 3 overall, 2 in DCM, and 4 in IHD patients. During a median follow-up of 7.5 years, 46% died, with an all-cause mortality rate of 6.1 per 100 patient-years. Higher CHA 2 DS 2 -VA scores were associated with increased all-cause and cardiovascular mortality in both IHD (HR 2.36, 95% CI 1.99–2.80, p < 0.001 for all-cause death) and DCM (HR 1.98, 95% CI 1.44–2.73, p < 0.001 for all-cause death). Each one-point increase in CHA 2 DS 2 -VA increased mortality risk (HR 1.4, 95% CI 1.34–1.47, p < 0.001 for all-cause death). No association was observed between CHA 2 DS 2 -VA and VA occurrence in the overall cohort or subgroups. Conclusion: The CHA 2 DS 2 -VA is strongly associated with all-cause and cardiovascular mortality in ICD patients with IHD and DCM, but does not predict VA. Thus, it may aid in mortality risk stratification but should not be used as a primary tool for arrhythmic risk assessment.
- 13 May 2026
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 13, 1743535
Open AccessCHA2DS2-VA score for predicting ventricular arrhythmias and mortality in ICD patients with ischemic heart disease and dilated cardiomyopathy: results from a prospective cohort
Background and aims: The revised CHA 2 DS 2 -VA score facilitates stroke risk assessment in patients with atrial fibrillation. This study investigates the value of the CHA 2 DS 2 -VA for prediction of all-cause and cardiovascular mortality and ventricular arrhythmia (VA) in patients with ischemic heart disease (IHD) and dilated cardiomyopathy (DCM) undergoing implantable cardioverter-defibrillator (ICD) therapy. Methods: We analyzed data from 1,626 ICD recipients with IHD ( n = 1,225) or DCM ( n = 401) enrolled in a prospective registry at University Hospital Basel. Patients were stratified into low and high CHA 2 DS 2 -VA groups based on median score within each condition. Mortality and VA outcomes were assessed using Kaplan–Meier survival analysis and Cox proportional hazards models. Results: The median CHA 2 DS 2 -VA was 3 overall, 2 in DCM, and 4 in IHD patients. During a median follow-up of 7.5 years, 46% died, with an all-cause mortality rate of 6.1 per 100 patient-years. Higher CHA 2 DS 2 -VA scores were associated with increased all-cause and cardiovascular mortality in both IHD (HR 2.36, 95% CI 1.99–2.80, p < 0.001 for all-cause death) and DCM (HR 1.98, 95% CI 1.44–2.73, p < 0.001 for all-cause death). Each one-point increase in CHA 2 DS 2 -VA increased mortality risk (HR 1.4, 95% CI 1.34–1.47, p < 0.001 for all-cause death). No association was observed between CHA 2 DS 2 -VA and VA occurrence in the overall cohort or subgroups. Conclusion: The CHA 2 DS 2 -VA is strongly associated with all-cause and cardiovascular mortality in ICD patients with IHD and DCM, but does not predict VA. Thus, it may aid in mortality risk stratification but should not be used as a primary tool for arrhythmic risk assessment.
- Open Access
- 31 October 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 9 (11)
Hybrid lead extraction and reconstruction of the superior vena cava and right atrium for a rare type of superior vena cava syndrome: a case report
Background: Superior vena cava (SVC) syndrome is caused by a partial or total obstruction of the SVC. In patients with vena cava syndrome due to endovascular pacemaker leads, lead extraction and endovascular stenting is the first-line treatment with high success rates. Case summary: At age 41, a patient presented with exercise intolerance and swelling of the hands and head with exertion and after sleeping in supine position. The patient had received endovascular pacemaker leads at the age of 21. Computed tomography showed a stenosis of the SVC with subtotal occlusion of the caudal part of the SVC and a large mass (likely fibrous tissue) around the pacing leads within the right atrium resulting in an upper and lower compartment of the right atrium. Since a percutaneous interventional approach was deemed unsuitable, a hybrid surgical approach with lead extraction and reconstruction of the right atrium and SVC using a bovine pericardial patch was performed. After an uneventful procedure, the patient experienced immediate symptom relief and was discharged in good condition. Discussion: Pronounced fibrous tissue can form in patients with implanted endovascular leads with the need for cardiac surgical support. Close interdisciplinary collaboration was the key to success in this hybrid approach.
- 31 October 2025
- Published by Oxford University Press (OUP) in European Heart Journal - Case Reports
- Vol. 9 (11)
Open AccessHybrid lead extraction and reconstruction of the superior vena cava and right atrium for a rare type of superior vena cava syndrome: a case report
Background: Superior vena cava (SVC) syndrome is caused by a partial or total obstruction of the SVC. In patients with vena cava syndrome due to endovascular pacemaker leads, lead extraction and endovascular stenting is the first-line treatment with high success rates. Case summary: At age 41, a patient presented with exercise intolerance and swelling of the hands and head with exertion and after sleeping in supine position. The patient had received endovascular pacemaker leads at the age of 21. Computed tomography showed a stenosis of the SVC with subtotal occlusion of the caudal part of the SVC and a large mass (likely fibrous tissue) around the pacing leads within the right atrium resulting in an upper and lower compartment of the right atrium. Since a percutaneous interventional approach was deemed unsuitable, a hybrid surgical approach with lead extraction and reconstruction of the right atrium and SVC using a bovine pericardial patch was performed. After an uneventful procedure, the patient experienced immediate symptom relief and was discharged in good condition. Discussion: Pronounced fibrous tissue can form in patients with implanted endovascular leads with the need for cardiac surgical support. Close interdisciplinary collaboration was the key to success in this hybrid approach.
- Open Access
- 23 October 2025
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 27 (11)
Anterior mitral isthmus line using pulsed-field ablation with the pentaspline catheter or radiofrequency ablation: procedural characteristics, safety, and mid-term outcomes
Aims: Pulsed-field ablation (PFA) is a non-thermal energy source for pulmonary vein isolation (PVI), offering advantages in safety and procedural efficiency. However, data comparing anterior mitral isthmus line (MIL) ablation using PFA vs. conventional radiofrequency ablation (RFA) are scarce. This study aimed to compare procedural characteristics, safety, and arrhythmia recurrence following PVI with additional anterior MIL ablation using PFA vs. RFA. Methods and results: In this prospective, single-centre analysis from the SWISS-AF-PVI registry, 129 patients (median age 70 years, 40% female) undergoing PVI with anterior MIL ablation were included. Patients received either PFA with a pentaspline catheter (n = 61) or RFA using a 3.5 mm irrigated tip catheter (n = 68). Procedural parameters, complications, and arrhythmia recurrence were assessed over a median follow-up of 327 days. PFA significantly reduced total procedure time (71 vs. 108 min, P < 0.001), LA dwell time (53 vs. 80 min, P < 0.001), and ablation time (27 vs. 50 min, P < 0.001) compared to RFA. MIL ablation with PFA required fewer applications (14; 35 s vs. 473 s RFA, P < 0.001). Arrhythmia-free survival was similar between groups (PFA 48.8% vs. RFA 61.8%, P = 0.34). Among 34 patients undergoing redo procedures, incomplete MIL was found in 53%, with no significant difference between groups. Three major complications occurred. Conclusion: Anterior MIL ablation using PFA is feasible, safe, and more time-efficient than RFA, with comparable mid-term arrhythmia outcomes. However, high rates of MIL reconnection and arrhythmia recurrence highlights the need to improve lesion durability.
- 23 October 2025
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 27 (11)
Open AccessAnterior mitral isthmus line using pulsed-field ablation with the pentaspline catheter or radiofrequency ablation: procedural characteristics, safety, and mid-term outcomes
Aims: Pulsed-field ablation (PFA) is a non-thermal energy source for pulmonary vein isolation (PVI), offering advantages in safety and procedural efficiency. However, data comparing anterior mitral isthmus line (MIL) ablation using PFA vs. conventional radiofrequency ablation (RFA) are scarce. This study aimed to compare procedural characteristics, safety, and arrhythmia recurrence following PVI with additional anterior MIL ablation using PFA vs. RFA. Methods and results: In this prospective, single-centre analysis from the SWISS-AF-PVI registry, 129 patients (median age 70 years, 40% female) undergoing PVI with anterior MIL ablation were included. Patients received either PFA with a pentaspline catheter (n = 61) or RFA using a 3.5 mm irrigated tip catheter (n = 68). Procedural parameters, complications, and arrhythmia recurrence were assessed over a median follow-up of 327 days. PFA significantly reduced total procedure time (71 vs. 108 min, P < 0.001), LA dwell time (53 vs. 80 min, P < 0.001), and ablation time (27 vs. 50 min, P < 0.001) compared to RFA. MIL ablation with PFA required fewer applications (14; 35 s vs. 473 s RFA, P < 0.001). Arrhythmia-free survival was similar between groups (PFA 48.8% vs. RFA 61.8%, P = 0.34). Among 34 patients undergoing redo procedures, incomplete MIL was found in 53%, with no significant difference between groups. Three major complications occurred. Conclusion: Anterior MIL ablation using PFA is feasible, safe, and more time-efficient than RFA, with comparable mid-term arrhythmia outcomes. However, high rates of MIL reconnection and arrhythmia recurrence highlights the need to improve lesion durability.
- Open Access
- 17 June 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (7)
Occurrence of premature battery depletion in a large multicentre registry of subcutaneous cardioverter-defibrillator patients
Aims: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) have become established in preventing sudden cardiac death, with some advantages over transvenous defibrillator systems, including a lower incidence of lead failures. Despite technological advancements, S-ICD carriers may suffer from significant complications, such as premature battery depletion (PBD), that led to an advisory for nearly 40 000 patients. This multicentre study evaluated the incidence of PBD in a large set of S-ICD patients. Methods and results: Data from patients implanted with S-ICD models A209 and A219 between October 2012 and July 2023 across nine centres in Europe and the USA were reviewed. Incidence and implications of PBD, defined as clinically observed sudden drop in battery longevity, were analysed and compared to PBD with the definition of battery depletion within 60 months. Prospectively collected clinical data were obtained retrospectively from medical records, device telemetry, and manufacturer reports. This registry is listed on ClinicalTrials.gov (NCT05713708). Of the 1112 S-ICD devices analysed, 547 (49.2%) were equipped with a potentially affected capacitor linked to PBD occurrence, currently under Food and Drug Administration advisory. The median follow-up time for all patients was 46 [inter-quartile range (IQR) 24–63] months. Clinically suspected PBD was observed in 159 (29.1%) of cases, with a median time to generator removal or replacement of 65 (IQR 55–72) months, indicative of significant deviations from expected battery lifespan. Manufacturer confirmation of PBD was made in 91.7% of devices returned for analysis. No cases of PBD were observed in devices that were not under advisory. Conclusion: This manufacturer-independent analysis highlights a notable incidence of PBD in patients equipped with S-ICD models under advisory, and the rate of PBD in this study corresponds to the rate currently estimated by the manufacturer. To the best of our knowledge, this provides the largest contemporary peer-reviewed study cohort investigating the actual incidence of PBD in S-ICD patients. These findings emphasize the importance of post-market registries in collaboration between clinicians and the manufacturer to optimize safety and efficacy in S-ICD treatment.
- 17 June 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (7)
Open AccessOccurrence of premature battery depletion in a large multicentre registry of subcutaneous cardioverter-defibrillator patients
Aims: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) have become established in preventing sudden cardiac death, with some advantages over transvenous defibrillator systems, including a lower incidence of lead failures. Despite technological advancements, S-ICD carriers may suffer from significant complications, such as premature battery depletion (PBD), that led to an advisory for nearly 40 000 patients. This multicentre study evaluated the incidence of PBD in a large set of S-ICD patients. Methods and results: Data from patients implanted with S-ICD models A209 and A219 between October 2012 and July 2023 across nine centres in Europe and the USA were reviewed. Incidence and implications of PBD, defined as clinically observed sudden drop in battery longevity, were analysed and compared to PBD with the definition of battery depletion within 60 months. Prospectively collected clinical data were obtained retrospectively from medical records, device telemetry, and manufacturer reports. This registry is listed on ClinicalTrials.gov (NCT05713708). Of the 1112 S-ICD devices analysed, 547 (49.2%) were equipped with a potentially affected capacitor linked to PBD occurrence, currently under Food and Drug Administration advisory. The median follow-up time for all patients was 46 [inter-quartile range (IQR) 24–63] months. Clinically suspected PBD was observed in 159 (29.1%) of cases, with a median time to generator removal or replacement of 65 (IQR 55–72) months, indicative of significant deviations from expected battery lifespan. Manufacturer confirmation of PBD was made in 91.7% of devices returned for analysis. No cases of PBD were observed in devices that were not under advisory. Conclusion: This manufacturer-independent analysis highlights a notable incidence of PBD in patients equipped with S-ICD models under advisory, and the rate of PBD in this study corresponds to the rate currently estimated by the manufacturer. To the best of our knowledge, this provides the largest contemporary peer-reviewed study cohort investigating the actual incidence of PBD in S-ICD patients. These findings emphasize the importance of post-market registries in collaboration between clinicians and the manufacturer to optimize safety and efficacy in S-ICD treatment.
- Open Access
- 3 June 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (6)
Incidence, implications, and management of sense-B-noise failure in subcutaneous cardioverter-defibrillator patients: insights from a large multicentre registry
Aims: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) offer potentially distinct advantages over transvenous defibrillator systems. Recent randomized trials showed significantly lower lead failure rates than transvenous ICD. Still, S-ICDs remain associated with the risk of inappropriate shocks (IAS). While previous studies have reported varying causes of IAS, this study explores a rare cause of IAS, referred to as ‘sense-B-noise.’ It was recently described in case series, but its incidence has not been studied in a large cohort of S-ICD patients. Methods and results: We retrospectively reviewed data from patients implanted with S-ICD models 1010, A209, and A219 between October 2009 and July 2023 across nine centres in Europe and the USA. The analysis concentrated on determining the incidence and understanding the implications of sense-B-noise events. Sense-B-noise represents a rare manifestation of distinct electrogram abnormalities within the primary and alternate sensing vectors. Data were collected from medical records, device telemetry, and manufacturer reports for investigation. This registry is registered on clinicaltrials.gov (NCT05713708). Subcutaneous implantable cardioverter-defibrillator devices of the 1158 patients were analysed. The median follow-up time for all patients was 46 (IQR 23–64) months. In 107 patients (9.2%) ≥1 IAS was observed during follow-up. Sense-B-noise failure was diagnosed in six (0.5 and 5.6% of all IAS) patients, in all patients, the diagnosis was made after an IAS episode. Median lead dwell time in the affected patients was 23 (2–70) months. To resolve the sense-B-noise defect, in three patients reprogramming to the secondary vector was undertaken, and two patients underwent system removal with subsequent S-ICD reimplantation due to low amplitude in the secondary vector. In one patient, the secondary vector was initially programmed, and subsequently, an S-ICD system exchange was performed due to T-wave-oversensing IAS episodes. Conclusion: This multicentre analysis’ findings shed light on a rare but clinically highly significant adverse event in S-ICD therapy. To our knowledge, we provide the first systematic multicentre analysis investigating the incidence of sense-B-noise. Due to being difficult to diagnose and limited options for resolution, management of sense-B-noise is challenging. Complete system exchange may be the only option for some patients. Educating healthcare providers involved in S-ICD patient care is crucial for ensuring accurate diagnosis and effective management of sense-B-noise issues.
- 3 June 2024
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 26 (6)
Open AccessIncidence, implications, and management of sense-B-noise failure in subcutaneous cardioverter-defibrillator patients: insights from a large multicentre registry
Aims: Subcutaneous implantable cardioverter-defibrillators (S-ICDs) offer potentially distinct advantages over transvenous defibrillator systems. Recent randomized trials showed significantly lower lead failure rates than transvenous ICD. Still, S-ICDs remain associated with the risk of inappropriate shocks (IAS). While previous studies have reported varying causes of IAS, this study explores a rare cause of IAS, referred to as ‘sense-B-noise.’ It was recently described in case series, but its incidence has not been studied in a large cohort of S-ICD patients. Methods and results: We retrospectively reviewed data from patients implanted with S-ICD models 1010, A209, and A219 between October 2009 and July 2023 across nine centres in Europe and the USA. The analysis concentrated on determining the incidence and understanding the implications of sense-B-noise events. Sense-B-noise represents a rare manifestation of distinct electrogram abnormalities within the primary and alternate sensing vectors. Data were collected from medical records, device telemetry, and manufacturer reports for investigation. This registry is registered on clinicaltrials.gov (NCT05713708). Subcutaneous implantable cardioverter-defibrillator devices of the 1158 patients were analysed. The median follow-up time for all patients was 46 (IQR 23–64) months. In 107 patients (9.2%) ≥1 IAS was observed during follow-up. Sense-B-noise failure was diagnosed in six (0.5 and 5.6% of all IAS) patients, in all patients, the diagnosis was made after an IAS episode. Median lead dwell time in the affected patients was 23 (2–70) months. To resolve the sense-B-noise defect, in three patients reprogramming to the secondary vector was undertaken, and two patients underwent system removal with subsequent S-ICD reimplantation due to low amplitude in the secondary vector. In one patient, the secondary vector was initially programmed, and subsequently, an S-ICD system exchange was performed due to T-wave-oversensing IAS episodes. Conclusion: This multicentre analysis’ findings shed light on a rare but clinically highly significant adverse event in S-ICD therapy. To our knowledge, we provide the first systematic multicentre analysis investigating the incidence of sense-B-noise. Due to being difficult to diagnose and limited options for resolution, management of sense-B-noise is challenging. Complete system exchange may be the only option for some patients. Educating healthcare providers involved in S-ICD patient care is crucial for ensuring accurate diagnosis and effective management of sense-B-noise issues.
- Open Access
- 8 August 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (16) , 5175
Transvenous Lead Extraction during Cardiac Implantable Device Upgrade: Results from the Multicenter Swiss Lead Extraction Registry
Background: Device patients may require upgrade interventions from simpler to more complex cardiac implantable electronic devices. Prior to upgrading interventions, clinicians need to balance the risks and benefits of transvenous lead extraction (TLE), additional lead implantation or lead abandonment. However, evidence on procedural outcomes of TLE at the time of device upgrade is scarce. Methods: This is a post hoc analysis of the investigator-initiated multicenter Swiss TLE registry. The objectives were to assess patient and procedural factors influencing TLE outcomes at the time of device upgrades. Results: 941 patients were included, whereof 83 (8.8%) had TLE due to a device upgrade. Rotational mechanical sheaths were more often used in upgraded patients (59% vs. 42.7%, p = 0.015) and total median procedure time was longer in these patients (160 min vs. 105 min, p < 0.001). Clinical success rates of upgraded patients compared to those who received TLE due to other reasons were not different (97.6% vs. 93.0%, p = 0.569). Moreover, multivariable analysis showed that upgrade procedures were not associated with a greater risk for complications (HR 0.48, 95% confidence interval 0.14–1.57, p = 0.224; intraprocedural complication rate of upgraded patients 7.2% vs. 5.5%). Intraprocedural complications of upgraded patients were mostly associated with the implantation and not the extraction procedure (67% vs. 33% of complications). Conclusions: TLE during device upgrade is effective and does not attribute a disproportionate risk to the upgrade procedure.
- 8 August 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (16) , 5175
Open AccessTransvenous Lead Extraction during Cardiac Implantable Device Upgrade: Results from the Multicenter Swiss Lead Extraction Registry
Background: Device patients may require upgrade interventions from simpler to more complex cardiac implantable electronic devices. Prior to upgrading interventions, clinicians need to balance the risks and benefits of transvenous lead extraction (TLE), additional lead implantation or lead abandonment. However, evidence on procedural outcomes of TLE at the time of device upgrade is scarce. Methods: This is a post hoc analysis of the investigator-initiated multicenter Swiss TLE registry. The objectives were to assess patient and procedural factors influencing TLE outcomes at the time of device upgrades. Results: 941 patients were included, whereof 83 (8.8%) had TLE due to a device upgrade. Rotational mechanical sheaths were more often used in upgraded patients (59% vs. 42.7%, p = 0.015) and total median procedure time was longer in these patients (160 min vs. 105 min, p < 0.001). Clinical success rates of upgraded patients compared to those who received TLE due to other reasons were not different (97.6% vs. 93.0%, p = 0.569). Moreover, multivariable analysis showed that upgrade procedures were not associated with a greater risk for complications (HR 0.48, 95% confidence interval 0.14–1.57, p = 0.224; intraprocedural complication rate of upgraded patients 7.2% vs. 5.5%). Intraprocedural complications of upgraded patients were mostly associated with the implantation and not the extraction procedure (67% vs. 33% of complications). Conclusions: TLE during device upgrade is effective and does not attribute a disproportionate risk to the upgrade procedure.
- Open Access
- 15 June 2023
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 10, 1217523
Follow-up of CRT-D patients downgraded to CRT-P at the time of generator exchange
Background: Some patients with cardiac resynchronisation therapy (CRT) experience super-response (LVEF improvements to ≥50%). At generator exchange (GE), downgrading (DG) from CRT-defibrillator (CRT-D) to CRT-pacemaker (CRT-P) could be an option for these patients on primary prevention ICD indication and no required ICD therapies. Long-term data on arrhythmic events in super-responders is scarce.Methods: CRT-D patients with LVEF improvement to ≥50% at GE were identified in four large centres for retrospective analysis. Mortality, significant ventricular tachyarrhythmia and appropriate ICD-therapy were determined, and patient analysis was split into two groups (downgraded to CRT-P or not).Results: Sixty-six patients (53% male, 26% coronary artery disease) on primary prevention were followed for a median of 129 months [IQR: 101–155] after implantation. 27 (41%) patients were downgraded to CRT-P at GE after a median of 68 [IQR: 58–98] months (LVEF 54% ± 4%). The other 39 (59%) continued with CRT-D therapy (LVEF 52% ± 6%). No cardiac death or significant arrhythmia occurred in the CRT-P group (median follow-up (FU) 38 months [IQR: 29–53]). Three appropriate ICD-therapies occurred in the CRT-D group [median FU 70 months (IQR: 39–97)]. Annualized event-rates after DG/GE were 1.5%/year and 1.0%/year in the CRT-D group and the whole cohort, respectively.Conclusions: No significant tachyarrhythmia were detected in the patients downgraded to CRT-P during follow-up. However, three events were observed in the CRT-D group. Whilst downgrading CRT-D patients is an option, a small residual risk for arrhythmic events remains and decisions regarding downgrade should be made on a case-by-case basis.
- 15 June 2023
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 10, 1217523
Open AccessFollow-up of CRT-D patients downgraded to CRT-P at the time of generator exchange
Background: Some patients with cardiac resynchronisation therapy (CRT) experience super-response (LVEF improvements to ≥50%). At generator exchange (GE), downgrading (DG) from CRT-defibrillator (CRT-D) to CRT-pacemaker (CRT-P) could be an option for these patients on primary prevention ICD indication and no required ICD therapies. Long-term data on arrhythmic events in super-responders is scarce.Methods: CRT-D patients with LVEF improvement to ≥50% at GE were identified in four large centres for retrospective analysis. Mortality, significant ventricular tachyarrhythmia and appropriate ICD-therapy were determined, and patient analysis was split into two groups (downgraded to CRT-P or not).Results: Sixty-six patients (53% male, 26% coronary artery disease) on primary prevention were followed for a median of 129 months [IQR: 101–155] after implantation. 27 (41%) patients were downgraded to CRT-P at GE after a median of 68 [IQR: 58–98] months (LVEF 54% ± 4%). The other 39 (59%) continued with CRT-D therapy (LVEF 52% ± 6%). No cardiac death or significant arrhythmia occurred in the CRT-P group (median follow-up (FU) 38 months [IQR: 29–53]). Three appropriate ICD-therapies occurred in the CRT-D group [median FU 70 months (IQR: 39–97)]. Annualized event-rates after DG/GE were 1.5%/year and 1.0%/year in the CRT-D group and the whole cohort, respectively.Conclusions: No significant tachyarrhythmia were detected in the patients downgraded to CRT-P during follow-up. However, three events were observed in the CRT-D group. Whilst downgrading CRT-D patients is an option, a small residual risk for arrhythmic events remains and decisions regarding downgrade should be made on a case-by-case basis.