Economic impact of cardiac implantable electronic device infections: cost analysis at one year in a large U.S. health insurer
Open Access
- 22 April 2020
- journal article
- research article
- Published by Taylor & Francis in Journal of Medical Economics
- Vol. 23 (7) , 698-705
Abstract
Aims: Cardiac device infections (CDIs) are serious adverse events associated with morbidity and mortality, significant costs and increased healthcare utilization. The objective of the current study was to characterize the CDI rate by device type, risk factors for infection and healthcare costs from a large U.S. health insurer perspective. Materials and Methods: A retrospective analysis of a large U.S. health insurer database identified commercial and Medicare Advantage with Part D (MAPD) members ≥18 years with ≥1 claim for a cardiac implantable electronic device (CIED) procedure between 10/01/2011 and 10/31/2015. CIEDs included pacemakers (IPG), implantable cardioverter defibrillators (ICDs), and cardiac resynchronization therapy - pacemakers without (CRT-P) and with defibrillation (CRT-D). Probabilities of CDI through one-year post implant was estimated using the Kaplan-Meier method. A regression model with stepwise variable selection was used to select risk factors associated with CDIs. Results: A total of 63,406 patients were included with an overall CDI rate of 1.28% (1.0% de novo and 1.74% replacement devices), varying by device type: IPG =0.91%; ICD =1.63%; CRT-P = 1.50%; CRT-D = 2.22%. The average adjusted annual medical costs were 2.4 times greater [95% confidence interval (CI) = 2.1-2.7] for those with an infection compared to those without, and the incremental cost difference was estimated to be $57,322 [95% CI $46,572-$70,484]. Observed risk factors of CDIs included prior device infection [Odds ratio (OR) = 11.356; 95% CI =7.923-16.276], undergoing a CIED replacement procedure (OR =1.644; 95% CI =1.361-1.987), implantation of a high-power device (OR =1.354; 95% CI =1.115-1.643), and younger age (age <65) (OR =1.607; 95% CI =1.307-1.976). Conclusions: The CDI rate at one year ranged from 0.91% - 2.22% depending on device type. Management of CDIs among commercial and MAPD members is associated with high healthcare expenditures.Keywords
This publication has 29 references indexed in Scilit:
- Treatment patterns, costs, and mortality among Medicare beneficiaries with CIED infectionPacing and Clinical Electrophysiology, 2018
- Cardiac implantable electronic device infections: Who is at greatest risk?Heart Rhythm, 2017
- Device therapy in cardiac disease: a success storyEuropean Heart Journal, 2015
- Risk factors for cardiac implantable electronic device infection: a systematic review and meta-analysisEP Europace, 2015
- Use of an Antibacterial Envelope is Associated with Reduced Cardiac Implantable Electronic Device Infections in High‐Risk PatientsPacing and Clinical Electrophysiology, 2012
- Mortality and Cost Associated With Cardiovascular Implantable Electronic Device InfectionsArchives of internal medicine (1960), 2011
- 16-Year Trends in the Infection Burden for Pacemakers and Implantable Cardioverter-Defibrillators in the United StatesJACC, 2011
- 50th Anniversary of the First Successful Permanent Pacemaker Implantation in the United States: Historical Review and Future DirectionsThe American Journal of Cardiology, 2010
- Continued Rise in Rates of Cardiovascular Implantable Electronic Device Infections in the United States: Temporal Trends and Causative InsightsPacing and Clinical Electrophysiology, 2010
- Temporal trends in permanent pacemaker implantation: A population-based studyAmerican Heart Journal, 2008