Jennifer A. Hinnenthal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jennifer A. Hinnenthal has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
Elizabeth L. Eby
Health Economics and Outcomes Research (HEOR), Medtronic, Inc, Mounds View, MN, USA
1 shared publicationEric Berryman
Arizona Center for Pain and Supportive Care, Phoenix, AZ, USA
1 shared publicationKrisstin Hammond
Arizona Center for Pain and Supportive Care, Phoenix, AZ, USA
1 shared publicationLindsay G. S. Bengtson
HEOR, Optum Life Sciences, Eden Prairie, MN, USA
1 shared publicationLisa J. Stearns
Arizona Center for Pain and Supportive Care, Phoenix, AZ, USA
1 shared publicationMark L. Burton
Health Economics and Outcomes Research (HEOR), Medtronic, Inc, Mounds View, MN, USA
1 shared publication
Latest Publications
- Open Access
- 22 April 2020
- Published by Taylor & Francis in Journal of Medical Economics
- Vol. 23 (7) , 698-705
Economic impact of cardiac implantable electronic device infections: cost analysis at one year in a large U.S. health insurer
Aims: Cardiac device infections (CDIs) are serious adverse events associated with morbidity and mortality, significant costs and increased healthcare utilization. The objective of the current study was to characterize the CDI rate by device type, risk factors for infection and healthcare costs from a large U.S. health insurer perspective. Materials and Methods: A retrospective analysis of a large U.S. health insurer database identified commercial and Medicare Advantage with Part D (MAPD) members ≥18 years with ≥1 claim for a cardiac implantable electronic device (CIED) procedure between 10/01/2011 and 10/31/2015. CIEDs included pacemakers (IPG), implantable cardioverter defibrillators (ICDs), and cardiac resynchronization therapy - pacemakers without (CRT-P) and with defibrillation (CRT-D). Probabilities of CDI through one-year post implant was estimated using the Kaplan-Meier method. A regression model with stepwise variable selection was used to select risk factors associated with CDIs. Results: A total of 63,406 patients were included with an overall CDI rate of 1.28% (1.0% de novo and 1.74% replacement devices), varying by device type: IPG =0.91%; ICD =1.63%; CRT-P = 1.50%; CRT-D = 2.22%. The average adjusted annual medical costs were 2.4 times greater [95% confidence interval (CI) = 2.1-2.7] for those with an infection compared to those without, and the incremental cost difference was estimated to be $57,322 [95% CI $46,572-$70,484]. Observed risk factors of CDIs included prior device infection [Odds ratio (OR) = 11.356; 95% CI =7.923-16.276], undergoing a CIED replacement procedure (OR =1.644; 95% CI =1.361-1.987), implantation of a high-power device (OR =1.354; 95% CI =1.115-1.643), and younger age (age <65) (OR =1.607; 95% CI =1.307-1.976). Conclusions: The CDI rate at one year ranged from 0.91% - 2.22% depending on device type. Management of CDIs among commercial and MAPD members is associated with high healthcare expenditures.
- 22 April 2020
- Published by Taylor & Francis in Journal of Medical Economics
- Vol. 23 (7) , 698-705
Open AccessEconomic impact of cardiac implantable electronic device infections: cost analysis at one year in a large U.S. health insurer
Aims: Cardiac device infections (CDIs) are serious adverse events associated with morbidity and mortality, significant costs and increased healthcare utilization. The objective of the current study was to characterize the CDI rate by device type, risk factors for infection and healthcare costs from a large U.S. health insurer perspective. Materials and Methods: A retrospective analysis of a large U.S. health insurer database identified commercial and Medicare Advantage with Part D (MAPD) members ≥18 years with ≥1 claim for a cardiac implantable electronic device (CIED) procedure between 10/01/2011 and 10/31/2015. CIEDs included pacemakers (IPG), implantable cardioverter defibrillators (ICDs), and cardiac resynchronization therapy - pacemakers without (CRT-P) and with defibrillation (CRT-D). Probabilities of CDI through one-year post implant was estimated using the Kaplan-Meier method. A regression model with stepwise variable selection was used to select risk factors associated with CDIs. Results: A total of 63,406 patients were included with an overall CDI rate of 1.28% (1.0% de novo and 1.74% replacement devices), varying by device type: IPG =0.91%; ICD =1.63%; CRT-P = 1.50%; CRT-D = 2.22%. The average adjusted annual medical costs were 2.4 times greater [95% confidence interval (CI) = 2.1-2.7] for those with an infection compared to those without, and the incremental cost difference was estimated to be $57,322 [95% CI $46,572-$70,484]. Observed risk factors of CDIs included prior device infection [Odds ratio (OR) = 11.356; 95% CI =7.923-16.276], undergoing a CIED replacement procedure (OR =1.644; 95% CI =1.361-1.987), implantation of a high-power device (OR =1.354; 95% CI =1.115-1.643), and younger age (age <65) (OR =1.607; 95% CI =1.307-1.976). Conclusions: The CDI rate at one year ranged from 0.91% - 2.22% depending on device type. Management of CDIs among commercial and MAPD members is associated with high healthcare expenditures.
- Open Access
- 1 February 2016
- Published by Elsevier in Neuromodulation: Technology at the Neural Interface
- Vol. 19 (2) , 196-205
Health Services Utilization and Payments in Patients With Cancer Pain: A Comparison of Intrathecal Drug Delivery vs. Conventional Medical Management
- 1 February 2016
- Published by Elsevier in Neuromodulation: Technology at the Neural Interface
- Vol. 19 (2) , 196-205
Open AccessHealth Services Utilization and Payments in Patients With Cancer Pain: A Comparison of Intrathecal Drug Delivery vs. Conventional Medical Management