Silicone Sensing Phase for Detection of Aromatic Hydrocarbons in Water Employing Near-Infrared Spectroscopy
- 23 November 2004
- journal article
- research article
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 77 (1) , 72-77
Abstract
The use of silicone for detection of aromatic hydrocarbons in water using near-infrared spectroscopy is proposed. A sensing phase of poly(dimethylsiloxane) (PDMS) was prepared, and a rod of this material was adapted to a transflectance probe for measurements from 850 to 1800 nm. Deionized water samples contaminated separately with known amounts of benzene, toluene, ethylbenzene, and m-xylene were used for evaluation of the PDMS sensing phase, and measurements were made in a closed reactor with constant stirring. Equilibrium states were obtained after 90, 180, 360, and 405 min for benzene, toluene, ethylbenzene, and m-xylene, respectively. The PDMS sensing phase showed a reversible response, presenting linear response ranges up to 360, 290, 100, and 80 mg L-1, with detection limits of 8.0, 7.0, 2.6, and 3.0 mg L-1 for benzene, toluene, ethylbenzene, and m-xylene, respectively. Reference spectra obtained with different rods showed a relative standard deviation of 0.5%, indicating repeatability in the sensing phase preparation. A relative standard deviation of 6.7% was obtained for measurements performed with six different rods, using a 52 mg L-1 toluene aqueous solution. The sensing phase was evaluated for identification of sources of contamination of water in simulated studies, employing Brazilian gasoline type A (without ethanol), gasoline type C (with 25% of anhydrous ethanol), and diesel fuel. Principal component analysis was able to classify the water in distinct groups, contaminated by gasoline A, gasoline C, or diesel fuel.Keywords
This publication has 11 references indexed in Scilit:
- Determination of total sulfur in diesel fuel employing NIR spectroscopy and multivariate calibrationThe Analyst, 2003
- Classification of premium and regular gasoline by gas chromatography/mass spectrometry, principal component analysis and artificial neural networksForensic Science International, 2003
- Kinetic evaluation method for SPME‐NIR measurements of analytes with long equilibration timeField Analytical Chemistry & Technology, 2001
- Investigation of fiber-optic evanescent-wave sensors for detection of liquid hydrocarbonsSensors and Actuators B: Chemical, 1998
- Use of solid-phase extraction in the determination of benzene, toluene, ethylbenzene, xylene and cumene in spiked soil and investigation of soil spiking methodsThe Analyst, 1998
- Evanescent Fiber-Optic Chemical Sensor for Monitoring Volatile Organic Compounds in WaterAnalytical Chemistry, 1997
- Towards a remote IR fiber-optic sensor system for the determination of chlorinated hydrocarbons in waterSensors and Actuators B: Chemical, 1997
- Study of Analyte Diffusion into a Silicone-Clad Fiber-Optic Chemical Sensor by Evanescent Wave SpectroscopyApplied Spectroscopy, 1995
- Infrared attenuated total reflection spectroscopic investigations of the diffusion behaviour of chlorinated hydrocarbons into polymer membranesVibrational Spectroscopy, 1995
- A Fiber-Optic FT-NIR Evanescent Field Absorbance SensorApplied Spectroscopy, 1990