Improving Intra-Fractional Target Position Accuracy Using a 3D Surface Surrogate for Left Breast Irradiation Using the Respiratory-Gated Deep-Inspiration Breath-Hold Technique
Authors:
Open Access
- 22 May 2014
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 9 (5) , e97933
Abstract
To evaluate the use of 3D optical surface imaging as a surrogate for respiratory gated deep-inspiration breath-hold (DIBH) for left breast irradiation. Patients with left-sided breast cancer treated with lumpectomy or mastectomy were selected as candidates for DIBH treatment for their external beam radiation therapy. Treatment plans were created on both free breathing (FB) and DIBH computed tomography (CT) simulation scans to determine dosimetric benefits from DIBH. The Real-time Position Management (RPM) system was used to acquire patient's breathing trace during DIBH CT acquisition and treatment delivery. The reference 3D surface models from FB and DIBH CT scans were generated and transferred to the “AlignRT” system for patient positioning and real-time treatment monitoring. MV Cine images were acquired during treatment for each beam as quality assurance for intra-fractional position verification. The chest wall excursions measured on these images were used to define the actual target position during treatment, and to investigate the accuracy and reproducibility of RPM and AlignRT. Reduction in heart dose can be achieved using DIBH for left breast/chest wall radiation. RPM was shown to have inferior correlation with the actual target position, as determined by the MV Cine imaging. Therefore, RPM alone may not be an adequate surrogate in defining the breath-hold level. Alternatively, the AlignRT surface imaging demonstrated a superior correlation with the actual target positioning during DIBH. Both the vertical and magnitude real-time deltas (RTDs) reported by AlignRT can be used as the gating parameter, with a recommended threshold of ±3 mm and 5 mm, respectively. The RPM system alone may not be sufficient for the required level of accuracy in left-sided breast/CW DIBH treatments. The 3D surface imaging can be used to ensure patient setup and monitor inter- and intra- fractional motions. Furthermore, the target position accuracy during DIBH treatment can be improved by AlignRT as a superior surrogate, in addition to the RPM system.Keywords
This publication has 35 references indexed in Scilit:
- Assessment of set-up variability during deep inspiration breath hold radiotherapy for breast cancer patients by 3D-surface imagingRadiotherapy and Oncology, 2013
- A Voluntary Breath-Hold Treatment Technique for the Left Breast With Unfavorable Cardiac Anatomy Using Surface ImagingInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2012
- The dosimetric impact of respiratory breast movement and daily setup error on tangential whole breast irradiation using conventional wedge, field-in-field and irregular surface compensator techniquesJournal of Radiation Research, 2012
- Toxicité cardiaque de la radiothérapieCancer/Radiothérapie, 2011
- Cardiac-sparing radiotherapy for the left breast cancer with deep breath-holdingJapanese Journal of Radiology, 2009
- Cardiac Morbidity and Mortality After Breast Conservation Treatment in Patients with Early-Stage Breast Cancer and Preexisting Cardiac DiseaseClinical Breast Cancer, 2008
- Effects of radiotherapy and of differences in the extent of surgery for early breast cancer on local recurrence and 15-year survival: an overview of the randomised trialsThe Lancet, 2005
- Optically Guided Patient Positioning TechniquesSeminars in Radiation Oncology, 2005
- Deep inspiration breath hold and respiratory gating strategies for reducing organ motion in radiation treatmentSeminars in Radiation Oncology, 2004
- Internal mammary node coverage: an investigation of presently accepted techniquesInternational Journal of Radiation Oncology - Biology - Physics (IJROBP), 2000