YRYi Rong

Yi Rong

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yi Rong has a total of 13 co-authors. Here are the top co-authors by number of shared publications:

  • Arnab Chakravarti

    Department of Radiation Oncology Ohio State University Columbus OH USA

    2 shared publications
  • Allison M. Quick

    Department of Radiation Oncology, The Ohio State University Wexner Medical Center, The James Cancer Hospital, Columbus, Ohio, United States of America

    1 shared publication
  • Farzad Nazem

    Bu Ali Sina Univ, Fac Phys Educ & Sport Sci, Dept Sport Physiol, Hamadan, Hamadan, Iran

    1 shared publication
  • Li Zuo

    Radiologic Sciences and Respiratory Therapy Division, School of Health and Rehabilitation Sciences, The Ohio State University College of Medicine, Columbus, OH, USA

    1 shared publication
  • Majid S. Koozehchian

    Exercise and Sport Nutrition Laboratory, Department of Health & Kinesiology, Texas A&M University, College Station, TX 77843, USA

    1 shared publication
  • Meng Xu Welliver

    Department of Radiation Oncology, The Ohio State University Wexner Medical Center, The James Cancer Hospital, Columbus, Ohio, United States of America

    1 shared publication

Latest Publications

  • Open Access

    Commissioning and comprehensive evaluation of the ArcCHECK cylindrical diode array for VMAT pretreatment delivery QA

    by Vibha Chaswal, Michael Weldon, Nilendu Gupta, Arnab Chakravarti, Yi Rong

    We present commissioning and comprehensive evaluation for ArcCHECK as a QA equipment for volumetric‐modulated arc therapy (VMAT), using the 6 MV photon beam with and without the flattening filter, and the SNC patient software (version 6.2). In addition to commissioning involving absolute dose calibration, array calibration, and PMMA density verification, ArcCHECK was evaluated for its response dependency on linac dose rate, instantaneous dose rate, radiation field size, beam angle, and couch insertion. Scatter dose characterization, consistency and symmetry of response, and dosimetry accuracy evaluation for fixed aperture arcs and clinical VMAT patient plans were also investigated. All the evaluation tests were performed with the central plug inserted and the homogeneous PMMA density value. Results of gamma analysis demonstrated an overall agreement between ArcCHECK‐measured and TPS‐calculated reference doses. The diode based field size dependency was found to be within 0.5% of the reference. The dose rate‐based dependency was well within 1% of the TPS reference, and the angular dependency was found to be ± 3% of the reference, as tested for BEV angles, for both beams. Dosimetry of fixed arcs, using both narrow and wide field widths, resulted in clinically acceptable global gamma passing rates on the 3%/3 mm level and 10% threshold. Dosimetry of narrow arcs showed an improvement over published literature. The clinical VMAT cases demonstrated high level of dosimetry accuracy in gamma passing rates.PACS numbers: 87.56.Fc, 87.55.kh, 87.55.Qr


  • Open Access

    The role of exercise training on lipoprotein profiles in adolescent males

    by Majid S Koozehchian, Farzad Nazem, Richard B Kreider, William J Roberts, Thomas M Best, Yi Rong, Li Zuo

    Major cardiovascular disorders are being recognized earlier in life. In this study we examined the effects of swimming and soccer training on male adolescent lipid-lipoprotein profiles relative to a maturity matched control group to determine the effects of these exercises on specific cardiovascular risk and anti-risk factors. Forty five adolescent males (11.81 ± 1.38 yr) including swimmers (SW), soccer players (SO), and non-athlete, physically active individuals as controls (C), participated in this study. Training groups completed 12-wk exercise programs on three non-consecutive days per week. Plasma low-density lipoprotein (LDL), very low density lipoprotein (VLDL), high density lipoprotein (HDL), apolipoprotein A-I (apoA-I), apolipoprotein B (apoB), total cholesterol (TC), and triglyceride (TG) levels were measured in control, pre-training, during-training, and post-training. In response to the 12-wk training period, the SO group demonstrated a decrease in the mean LDL level compared to the SW and C (SW: 0.15%; SO: −9.51%; C: 19.59%; p < 0.001) groups. There was an increase in both the SW and SO groups vs. the control in mean HDL (SW: 5.66%; SO: 3.07%; C: −7.21%; p < 0.05) and apoA-I (SW: 3.86%; SO: 5.48%; C: −1.01%; p < 0.05). ApoB was considerably lower in the training groups vs. control (SW: −9.52%; SO: −13.87%; C: 21.09%; p < 0.05). ApoA-I/apoB ratio was significantly higher in training groups vs. control (SW: 16.74%; SO: 23.71%; C: −17.35%; p < 0.001). There were no significant differences between groups for other factors. The favorable alterations in LDL, HDL, apoA-I, and apoB observed in the training groups suggest that both regular swimming or soccer exercise can potentially mitigate cardiovascular risk in adolescent males.


  • Open Access

    Improving Intra-Fractional Target Position Accuracy Using a 3D Surface Surrogate for Left Breast Irradiation Using the Respiratory-Gated Deep-Inspiration Breath-Hold Technique

    by Yi Rong, Steve Walston, Meng Xu Welliver, Arnab Chakravarti, Allison M. Quick

    To evaluate the use of 3D optical surface imaging as a surrogate for respiratory gated deep-inspiration breath-hold (DIBH) for left breast irradiation. Patients with left-sided breast cancer treated with lumpectomy or mastectomy were selected as candidates for DIBH treatment for their external beam radiation therapy. Treatment plans were created on both free breathing (FB) and DIBH computed tomography (CT) simulation scans to determine dosimetric benefits from DIBH. The Real-time Position Management (RPM) system was used to acquire patient's breathing trace during DIBH CT acquisition and treatment delivery. The reference 3D surface models from FB and DIBH CT scans were generated and transferred to the “AlignRT” system for patient positioning and real-time treatment monitoring. MV Cine images were acquired during treatment for each beam as quality assurance for intra-fractional position verification. The chest wall excursions measured on these images were used to define the actual target position during treatment, and to investigate the accuracy and reproducibility of RPM and AlignRT. Reduction in heart dose can be achieved using DIBH for left breast/chest wall radiation. RPM was shown to have inferior correlation with the actual target position, as determined by the MV Cine imaging. Therefore, RPM alone may not be an adequate surrogate in defining the breath-hold level. Alternatively, the AlignRT surface imaging demonstrated a superior correlation with the actual target positioning during DIBH. Both the vertical and magnitude real-time deltas (RTDs) reported by AlignRT can be used as the gating parameter, with a recommended threshold of ±3 mm and 5 mm, respectively. The RPM system alone may not be sufficient for the required level of accuracy in left-sided breast/CW DIBH treatments. The 3D surface imaging can be used to ensure patient setup and monitor inter- and intra- fractional motions. Furthermore, the target position accuracy during DIBH treatment can be improved by AlignRT as a superior surrogate, in addition to the RPM system.