Five-Year Follow-up of Correction of Myopia: Posterior Chamber Phakic Intraocular Lens With a Central Port Design
Authors:
- José F. AlfonsoJAJosé F. Alfonso
- Luis Fernández-Vega-CuetoLFLuis Fernández-Vega-Cueto
- Belén Alfonso-BartolozziBABelén Alfonso-Bartolozzi
- Robert Montés-MicóRMRobert Montés-Micó
- Luis Fernández-VegaLFLuis Fernández-Vega
- 1 March 2019
- journal article
- research article
- Published by SLACK, Inc. in Journal of Refractive Surgery
- Vol. 35 (3) , 169-176
Abstract
PURPOSE: To assess the long-term correction of moderate to high myopia using a posterior chamber phakic intraocular lens with a central port design. METHODS: Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, intraocular pressure (IOP), endothelial cell density (ECD), vault, and adverse events over a 5-year period were evaluated retrospectively. RESULTS: A total of 147 eyes (83 patients) were evaluated. Mean postoperative UDVA and CDVA were 0.05 ± 0.11 and 0.02 ± 0.08 logMAR at 1 year and 0.13 ± 0.18 and 0.02 ± 0.09 logMAR at 5 years, respectively. More than 95% of eyes achieved CDVA of 20/25 or better at both follow-up periods. CDVA was unchanged or improved from one to three or more lines in all eyes. Preoperatively, mean spherical equivalent (SE) was −9.20 ± 3.02 diopters (D). At 1 year, the mean SE was −0.17 ± 0.26 D, with 91.53% of eyes within ±0.50 D and 100% of eyes within ±1.00 D of the target. At 5 years, the mean SE was −0.44 ± 0.47 D, with 67.4% of eyes within ±0.50 D and 90.1% of eyes within ±1.00 D of the target. Mean IOP was 12.74 ± 1.65 and 13.0 ± 2.03 mm Hg, at 1 and 5 years, respectively. No significant rise in IOP (> 20 mm Hg) occurred during the follow-up period. Mean ECD was 2,696 ± 358 and 2,645 ± 359 cells/mm 2 at 1 and 5 years, respectively, representing a non-significant loss of 0.43% from preoperative values ( P = .304). Mean vault changed significantly from 398 ± 187 µm at 1 year to 340 ± 163 µm at 5 years ( P < .001). No intraoperative or postoperative complications or adverse events occurred during the follow-up period. CONCLUSIONS: The good long-term outcomes found in this study support the use of this lens with a central port design for the correction of moderate to high myopia. [ J Refract Surg . 2019;35(3):169–176.]Keywords
This publication has 24 references indexed in Scilit:
- Outcomes of implantable collamer lens V4 and V4c for correction of high myopia – a case seriesNepalese Journal of Ophthalmology, 2016
- Long-Term Comparison of Posterior Chamber Phakic Intraocular Lens With and Without a Central Hole (Hole ICL and Conventional ICL) Implantation for Moderate to High Myopia and Myopic AstigmatismMedicine, 2016
- Implantable collamer lens V4b and V4c for correction of high myopiaJournal of Current Ophthalmology, 2015
- Posterior chamber collagen copolymer phakic intraocular lens with a central hole to correct myopia: One-year follow-upJournal of Cataract & Refractive Surgery, 2015
- Comparison of vault after implantation of posterior chamber phakic intraocular lens with and without a central holeJournal of Cataract & Refractive Surgery, 2015
- Clinical outcomes after implantation of a posterior chamber collagen copolymer phakic intraocular lens with a central hole for myopic correctionJournal of Cataract & Refractive Surgery, 2013
- Long-term evaluation of the central vault after phakic Collamer® lens (ICL) implantation using OCTGraefe's Archive for Clinical and Experimental Ophthalmology, 2012
- Implantable Collamer Posterior Chamber Intraocular Lenses: A Review of Potential ComplicationsJournal of Refractive Surgery, 2011
- Early clinical outcomes of implantation of posterior chamber phakic intraocular lens with a central hole (Hole ICL) for moderate to high myopiaBritish Journal of Ophthalmology, 2011
- Corneal endothelial assessment after ICL implantationJournal of Cataract & Refractive Surgery, 2004