Stair ascent kinematics affect UHMWPE wear and damage in total knee replacements
- 1 July 2006
- journal article
- research article
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 78B (1) , 15-19
Abstract
Investigations were performed to characterize the wear patterns of tibial inserts in a load‐controlled knee simulator by incorporating both normal gait and clinically acquired stair climbing kinematics and load conditions. Two different tibial insert designs were evaluated: the NexGen Cruciate Retaining Augmentable and NexGen Legacy Posterior Stabilized inserts. Two test conditions were run: standard gait only, and gait with bouts of stair climbing at a ratio of 70:1. Gravimetric wear measurements, damage and contact area assessments, and kinematic evaluations were performed. The addition of stair climbing kinematics significantly affected the wear behavior. Regardless of design, wear rates for standard gait tests were significantly higher than those that included bouts of stair climbing. The damage modes seen in both test conditions were primarily burnishing with secondary scratching and pitting. At 2 Mc, the damage areas were not significantly different between the two designs, but the damage area with stair climbing was significantly larger than that with gait alone. The fact that even small bouts of an additional activity of daily living could markedly impact wear simulator results calls into question the usefulness of studies that rely solely on kinematics and load inputs assumed from level gait. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2006Keywords
This publication has 13 references indexed in Scilit:
- Fluoroscopic and gait analysis of the functional performance in stair ascent of two total knee replacement designsGait & Posture, 2003
- Polyethylene Damage on the Nonarticular Surface of Modular Total Knee ProsthesesClinical Orthopaedics and Related Research, 2003
- Metrology to Quantify Wear and Creep of Polyethylene Tibial Knee InsertsClinical Orthopaedics and Related Research, 2003
- Aggressive Wear Testing of a Cross-Linked Polyethylene in Total Knee ArthroplastyClinical Orthopaedics and Related Research, 2002
- Effect of stair descent loading on ultra-high molecular weight polyethylene wear in a force-controlled knee simulatorProceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 2002
- Polyethylene Wear and Variations in Knee KinematicsClinical Orthopaedics and Related Research, 2001
- Effects of in vitro wear of machined and molded UHMWPE tibial inserts on TKR kinematicsJournal of Biomedical Materials Research, 2001
- Retrieval analysis of total knee prostheses: A method and its application to 48 total condylar prosthesesJournal of Biomedical Materials Research, 1983
- Measurements of repetitive activities of the kneeJournal of Biomechanics, 1975
- Biomechanical analysis of knee flexion and extensionJournal of Biomechanics, 1973