JCJocelyn M. Cottrell

Jocelyn M. Cottrell

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Jocelyn M. Cottrell has a total of 6 co-authors. Here are the top co-authors by number of shared publications:

  • Bridgette S. Furman

    Duke University, Durham, North Carolina

    1 shared publication
  • Elizabeth R. Myers

    Ground Floor Research Building, Biomedical Mechanics & Materials, Hospital for Special Surgery, 535 East 70th Street, 10021, New York, NY, USA

    1 shared publication
  • Joseph M. Lane

    Department of Orthopaedic Surgery, Hospital for Special Surgery, 535 East 70th Street, 10021, New York, NY, USA

    1 shared publication
  • Marjolein C. H. van der Meulen

    Nancy E. and Peter C. Meinig School of Biomedical Engineering, Cornell University, Ithaca, NY, USA; Research Division, Hospital for Special Surgery, New York, NY, USA

    1 shared publication
  • Omotunde Babalola

    Laboratory for Biomedical Mechanics and Materials, Hospital for Special Surgery, New York, New York

    1 shared publication
  • Timothy M. Wright

    Laboratory for Biomedical Mechanics and Materials, Hospital for Special Surgery, New York, New York

    1 shared publication

Latest Publications

  • Stair ascent kinematics affect UHMWPE wear and damage in total knee replacements

    by Jocelyn M. Cottrell, Omotunde Babalola, Bridgette S. Furman, Timothy M. Wright

    Investigations were performed to characterize the wear patterns of tibial inserts in a load‐controlled knee simulator by incorporating both normal gait and clinically acquired stair climbing kinematics and load conditions. Two different tibial insert designs were evaluated: the NexGen Cruciate Retaining Augmentable and NexGen Legacy Posterior Stabilized inserts. Two test conditions were run: standard gait only, and gait with bouts of stair climbing at a ratio of 70:1. Gravimetric wear measurements, damage and contact area assessments, and kinematic evaluations were performed. The addition of stair climbing kinematics significantly affected the wear behavior. Regardless of design, wear rates for standard gait tests were significantly higher than those that included bouts of stair climbing. The damage modes seen in both test conditions were primarily burnishing with secondary scratching and pitting. At 2 Mc, the damage areas were not significantly different between the two designs, but the damage area with stair climbing was significantly larger than that with gait alone. The fact that even small bouts of an additional activity of daily living could markedly impact wear simulator results calls into question the usefulness of studies that rely solely on kinematics and load inputs assumed from level gait. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2006


  • Assessing the Stiffness of Spinal Fusion in Animal Models

    by Jocelyn M. Cottrell, Marjolein C. H. van der Meulen, Joseph M. Lane, Elizabeth R. Myers

    The clinical goal of spinal fusion is to reduce motion and the associated pain. Therefore, measuring motion under loading is critical. The purpose of this study was to validate four-point bending as a means to mechanically evaluate simulated fusions in dog and rabbit spines. We hypothesized that this method would be more sensitive than manual palpation and would be able to distinguish unilateral vs bilateral fusion. Spines from four mixed breed dogs and four New Zealand white rabbits were used to simulate posterolateral fusion with polymethyl methacrylate as the fusion mass. We performed manual palpation and nondestructive mechanical testing in four-point bending in four planes of motion: flexion, extension, and right and left bending. This testing protocol was used for each specimen in three fusion modes: intact, unilateral, and bilateral fusion. Under manual palpation, all intact spines were rated as not fused, and all unilateral and bilateral simulated fusions were rated as fused. In four-point bending, dog spines were significantly stiffer after unilateral fusion compared with intact in all directions. Additionally, rabbit spines were stiffer in flexion and left bending after unilateral fusion. All specimens exhibited significant differences between intact and bilateral fusion except the rabbit in extension. For unilateral vs bilateral fusion, significant differences were present for right bending in the dog model and for flexion in the rabbit. Unilateral fusion can provide enough stability to constitute a fused grade by manual palpation but may not provide structural stiffness comparable to bilateral fusion.