Investigation of AAA dose calculation algorithm accuracy in surface and buildup region for 6MV photon beam using markus parallel-plate ion chamber
- 2 March 2019
- journal article
- research article
- Published by SAGE Publications in Journal of X-Ray Science and Technology
- Vol. 27 (2) , 361-369
Abstract
In radiotherapy, dose distributions are obtained by using dose calculation algorithms that are implanted in treatment planning systems (TPS). This study aims to compare the surface doses of separate field sizes calculated by different version of The Analytical Anisotropic Algorithm (AAA) and measured by the parallel-plate ion chamber that is admitted as the most reliable dosimetry system for the surface region dose measurements. In order to measure the near surface dose, water equivalent solid phantom was used and measurements were made for 6MV photon beam at 100 cm source-detector distance for 5×5, 10×10, and 20×20 cm2 field sizes. AAA 8.9 and AAA 15.1 versions of the Varian Eclipse TPS were used for surface dose calculations by generating beams with separate field sizes. The doses were read by considering the effective buildup thickness of Markus parallel-plate ion chamber. The surface doses using 6 MV photon beams for 10×10 cm2 field size at 0.07 mm were found to be 11.04%, 26.25%, and 19.69% for AAA v8.9, AAA v15.1 and Markus chamber, respectively. It was seen that for both of the AAA versions and Markus parallel-plate ion chamber, increasing field sizes also increase surface dose. For all field sizes, surface dose was lowest by using AAA v8.9 at 0.07 mm. The different versions of the same TPS algorithms may calculate the surface doses distinctively. After upgrading of TPS algorithms, surface doses should be calculated and compared by measurements with different dosimetry systems to better understand their calculation behaviors in the near surface region.Keywords
This publication has 11 references indexed in Scilit:
- A simple technique to improve calculated skin dose accuracy in a commercial treatment planning systemJournal of Applied Clinical Medical Physics, 2018
- Superficial dose evaluation of four dose calculation algorithmsRadiation Physics and Chemistry, 2017
- Comparative study of old and new versions of treatment planning system using dose volume histogram indices of clinical plansJournal of Medical Physics, 2016
- Validation of OSLD and a treatment planning system for surface dose determination in IMRT treatmentsMedical Physics, 2014
- 4. Treatment Planning AlgorithmsJournal of the ICRU, 2014
- Dose calculation algorithms in external beam photon radiation therapyInternational Journal of Cancer Therapy and Oncology, 2013
- An investigation of the depth dose in the build-up region, andsurface dose for a 6-MV therapeutic photon beam: Monte Carlo simulation and measurementsJournal of Radiation Research, 2012
- Surface dose measurements with GafChromic EBT film for 6 and 18MV photon beamsPhysica Medica, 2009
- Measurement of dose in the buildup region using fixed‐separation plane‐parallel ionization chambersMedical Physics, 1990
- Build-up region of megavoltage photon radiation sourcesMedical Physics, 1975