Integrating Sphere Finger-Photoplethysmography: Preliminary Investigation towards Practical Non-Invasive Measurement of Blood Constituents
Open Access
- 4 December 2015
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 10 (12) , e0143506
Abstract
The aim of this study was to compare conventional photoplethysmography (PPG) in a finger with PPG using an integrating sphere (ISPPG) to enhance scattered light collection. Two representative wavelengths were used; 1160 nm, a window through the absorption spectra of water and alcohol, and 1600 nm around where water absorption is high and there is an absorption peak of blood glucose. Simultaneous transmission-type measurements were made with conventional PPG and with ISPPG for each wavelength in the tips of index fingers of both hands in a total of 10 healthy young male and female volunteers (21.7 ± 1.6 years old). During a 5 min period in which subjects were in a relaxed state we determined the signal-to-noise ratio, SNR, and the PPG detectability (or sensitivity) by the two techniques. SNR during the test period was significantly higher with ISPPG as compared with conventional PPG, especially for the 1600 nm wavelength. PPG signals with 1600 nm could scarcely be detected by conventional PPG, while they could be detected with good sensitively by ISPPG. We conclude that under controlled conditions ISPPG has better SNR and higher sensitivity than conventional transmission PPG, especially in wavelength regions where water absorption is high but where there is potential for practical measurement of blood constituents including glucose.Keywords
This publication has 34 references indexed in Scilit:
- Validation of normalized pulse volume in the outer ear as a simple measure of sympathetic activity using warm and cold pressor tests: towards applications in ambulatory monitoringPhysiological Measurement, 2013
- An implantable optical blood pressure sensor based on pulse transit timeBiomedical Microdevices, 2012
- Towards Non-invasive Optical Blood Alcohol Measurement: Multi-variate Analysis of in vitro NIR SpectraIEEJ Transactions on Electronics, Information and Systems, 2012
- Photoplethysmography and its application in clinical physiological measurementPhysiological Measurement, 2007
- Contour analysis of the photoplethysmographic pulse measured at the fingerJournal Of Hypertension, 2006
- Pulse glucometry: a new approach for noninvasive blood glucose measurement using instantaneous differential near-infrared spectrophotometryJournal of Biomedical Optics, 2006
- Near-infrared transmittance pulse oximetry with laser diodesJournal of Biomedical Optics, 2003
- Noninvasive glucose sensing utilizing a digital closed-loop polarimetric approachIEEE Transactions on Biomedical Engineering, 1997
- In vivo reflectance of blood and tissue as a function of light wavelengthIEEE Transactions on Biomedical Engineering, 1990
- Model for laser Doppler measurements of blood flow in tissueApplied Optics, 1981