Comparison of two swept-source optical coherence tomography devices, a Scheimpflug camera system and a ray-tracing aberrometer in the measurement of corneal power in patients with cataract
Open Access
- 27 December 2023
- journal article
- research article
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 262 (5) , 1567-1578
Abstract
Purpose: To assess the differences and similarities in the corneal curvature obtained by two swept-source optical coherence tomography (SS-OCT) devices, Scheimpflug imaging system and one ray tracing aberrometer in patients with cataracts. Moreover, this study aimed to compare the differences in posterior corneal (PK), total corneal (TK) and true net power (TNP) measurements among the IOLMaster 700, CASIA2, and Pentacam. Methods: A total of 200 eyes of 200 patients (116 female, 58%) were enrolled in this study, with a mean age of 65.9 ± 9.5 years. The flattest (Kf), steepest (Ks), and mean cornal powers (Km), J0, and J45 were obtained using two SS-OCT-based biometric devices, one rotating camera system and one ray-tracing aberrometer. The PK, TK and TNP values were also measured using these devices. To evaluate the differences and similarities between the devicves, the Friedman test, Pearson correlation coefficient (r), intraclass coefficient correlation (ICC) and Bland‒Altman plots with 95% limits of agreement (LoA) were used, and boxplots and stacked histograms were generated to describe the distributions of the data. Results: There were no significant differences between the IOLMaster 700 and Pentacam for any of the keratometry values. Additionally, there were no significant differences between the IOLMaster 700 and iTrace in evaluating J0 and J45. Bland‒Altman plots revealed relatively wide LoA widths, almost larger than 1 diopter for the keratometry values and almost larger than 0.5 diopter for J0 and J45 values among the four devices. In terms of PK and TK values, significant differences and low ICCs were found among the three devices. Conclusions: Although strong correlations and good agreement were found among the IOLMaster700, CASIA2, Pentacam and iTrace for Kf, Ks, Km and J0, J45, it seems that the measurements should not be used interchangeably because of the wide LoA widths and the presence of significant differences among the devices. Similarly, due to significant differences and low ICCs, the PK, TK and TNP values obtained by IOLMaster 700, CASIA2, and Pentacam should not be used interchangeably.Keywords
Funding Information
- Tianjin Key Medical Discipline (Specialty) Construction Project (TJYXZDXK-037A)
This publication has 28 references indexed in Scilit:
- Analysis of Intrasession Repeatability of Ocular Aberrometric Measurements and Validation of Keratometry Provided by a New Integrated System in Mild to Moderate KeratoconusCornea, 2019
- User's guide to correlation coefficientsTurkish Journal of Emergency Medicine, 2018
- Ocular biometric measurements in cataract surgery candidates in PortugalPLOS ONE, 2017
- Comparison of the Astigmatic Power of Toric Intraocular Lenses Using Three Toric CalculatorsYonsei Medical Journal, 2015
- Agreement Between Pentacam and IOLMaster in Patients Undergoing Toric IOL ImplantationJournal of Refractive Surgery, 2013
- Comparison of refractive outcomes using five devices for the assessment of preoperative corneal powerClinical & Experimental Ophthalmology, 2012
- Analysis of biometry and prevalence data for corneal astigmatism in 23 239 eyesJournal of Cataract & Refractive Surgery, 2010
- Power vector analysis of the optical outcome of refractive surgeryJournal of Cataract & Refractive Surgery, 2001
- Principles of Ray Tracing AberrometryJournal of Refractive Surgery, 2000
- Power Vectors: An Application of Fourier Analysis to the Description and Statistical Analysis of Refractive ErrorOptometry and Vision Science, 1997