Ocular biometric measurements in cataract surgery candidates in Portugal
Open Access
- 5 October 2017
- journal article
- research article
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 12 (10) , e0184837
Abstract
Describe the ocular biometric parameters and their associations in a population of cataract surgery candidates. A cross-sectional study of 13,012 eyes of 6,506 patients was performed. Biometric parameters of the eyes were measured by optical low-coherence reflectometry. The axial length (AL), mean keratometry (K) and astigmatism, anterior chamber depth (ACD) (epithelium to lens), lens thickness (LT), and Corneal Diameter (CD) were evaluated. The mean age was 69 ± 10 years (44–99 years). Mean AL, Km, and ACD were 23.87 ± 1.55 mm (19.8–31.92 mm), 43.91 ± 1.71 D (40.61–51.14 D), and 3.25 ± 0.44 mm (2.04–5.28 mm), respectively. The mean LT was 4.32 ± 0.49 mm (2.73–5.77 mm) and the mean CD was 12.02 ± 0.46 mm (10.50–14.15 mm). The mean corneal astigmatism was 1.08 ± 0.84 D (0.00–7.58 D) and 43.5% of eyes had astigmatism ≥ 1.00 D. Male patients had longer AL and ACDs (p < .001) and flatter corneas (p < .001). In regression models considering age, gender, Km, ACD, LT, and CD, a longer AL was associated with being male and having higher ACD, LT and CD. These data represent normative biometric values for the Portuguese population. The greatest predictor of ocular biometrics was gender. There was no significant correlation between age and AL, ACD, or Km. These results may be relevant in the evaluation of refractive error and in the calculation of intraocular lens power.Keywords
Funding Information
- Fundação para a Ciência e a Tecnologia (PEst-OE/FIS/UI0068/2011 and UID/FIS/00068/2013)
- Sociedade Portuguesa de Oftalmologia (N/A)
This publication has 25 references indexed in Scilit:
- Comparison of 2 laser instruments for measuring axial lengthJournal of Cataract & Refractive Surgery, 2010
- Distribution of Axial Length and Ocular Biometry Measured Using Partial Coherence Laser Interferometry (IOL Master) in an Older White PopulationOphthalmology, 2010
- Distribution and Determinants of Ocular Biometric Parameters in an Asian Population: The Singapore Malay Eye StudyInvestigative Ophthalmology & Visual Science, 2010
- Association of Age, Stature, and Education With Ocular Dimensions in an Older White PopulationArchives of Ophthalmology (1950), 2009
- Variability of axial length, anterior chamber depth, and lens thickness in the cataractous eyeJournal of Cataract & Refractive Surgery, 2008
- Variation of the Contribution from Axial Length and Other Oculometric Parameters to Refraction by Age and EthnicityInvestigative Ophthalmology & Visual Science, 2007
- Improved accuracy of intraocular lens power calculation with the Zeiss IOLMasterActa Ophthalmologica Scandinavica, 2006
- A new non-contact optical device for ocular biometryBritish Journal of Ophthalmology, 2002
- Reduction in Axial Length with AgeOptometry and Vision Science, 1987
- ASTIGMATISM ITS COMPONENTS AND THEIR CHANGES WITH AGEOptometry and Vision Science, 1971