Barrett RX tool for intraocular lens power calculation in pseudophakic eyes undergoing intraocular lens exchange
- 1 November 2025
- journal article
- research article
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (11) , 972-978
Abstract
Purpose: To assess the accuracy of refraction prediction after intraocular lens (IOL) exchange using a software integrated in a Scheimpflug-based biometer. Setting: 2 tertiary referral hospitals. Design: Case series. Methods: Eyes that underwent uneventful bag-to-bag IOL exchange between 2017 and 2024 and complete preoperative and postoperative measurements were included. IOL exchange was performed by 2 experienced surgeons. IOL power was calculated using the Barrett RX formula integrated in Pentacam software, incorporating both phakic and pseudophakic biometric data and subjective refraction. Prediction errors were computed by comparing actual postoperative and predicted refractions. Moreover, an unpublished estimation formula was evaluated. Results: 25 eyes of 25 patients (mean age 60.2 ± 11.4 years) were included. Mean interval between primary IOL implantation and exchange was 25.3 ± 31.5 weeks. In 11 of 25 eyes, a different IOL model was implanted during the exchange. Using the Barrett RX formula, the mean prediction error (MPE) was 0.02 ± 0.32 diopters (D), mean absolute error (MAE) 0.27 ± 0.17 D, and median absolute error (MedAE) 0.22 D. A total of 56% and 92% of eyes were within ±0.25 D and ±0.50 D of target refraction, respectively. The conventional formula yielded a comparable MPE of –0.12 ± 0.68 D ( P = .479), but higher MAE and MedAE (0.53 ± 0.42 D and 0.40 D, P < .001), with 32% and 56% of eyes within ±0.25 D and ±0.50 D, respectively. Conclusions: The Barrett RX formula was demonstrated to be an efficacious method for calculating IOL power in eyes undergoing IOL exchange, with more than half of cases within ±0.25 D of the predicted postexchange refraction.Keywords
This publication has 28 references indexed in Scilit:
- Visual Acuity Outcomes and Complications after Intraocular Lens ExchangeOphthalmology, 2023
- Monofocal intraocular lens with enhanced intermediate function as substitute for multifocal intraocular lens in positive dysphotopsiaAmerican Journal of Ophthalmology Case Reports, 2022
- Update on Intraocular Lens Power Calculation Study ProtocolsOphthalmology, 2021
- Risk factors for refractive error after cataract surgery: Analysis of 282 811 cataract extractions reported to the European Registry of Quality Outcomes for cataract and refractive surgeryJournal of Cataract & Refractive Surgery, 2018
- Comparison of Axial Length, Corneal Curvature, and Anterior Chamber Depth Measurements of 2 Recently Introduced Devices to a Known BiometerAmerican Journal of Ophthalmology, 2017
- Protocols for Studies of Intraocular Lens Formula AccuracyAmerican Journal of Ophthalmology, 2015
- Indications and Outcomes of Intraocular Lens Exchange During a Recent 5-Year PeriodAmerican Journal of Ophthalmology, 2014
- Dissatisfaction after implantation of multifocal intraocular lensesJournal of Cataract & Refractive Surgery, 2011
- Laser in situ keratomileusis versus lens-based surgery for correcting residual refractive error after cataract surgeryJournal of Cataract & Refractive Surgery, 2008
- Postoperative refractive error resulting from incorrectly labeled intraocular lens powerJournal of Cataract & Refractive Surgery, 2000