Tyll Jandewerth
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tyll Jandewerth has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
- Thomas Kohnen
Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany
9 shared publications - Klemens Paul Kaiser
Department of Ophthalmology, Goethe-University, Frankfurt, Germany
7 shared publications - Christoph Lwowski
Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany
5 shared publications - Julian Bucur
Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany
3 shared publications Klemens Paul Kaiser
Klinik für Augenheilkunde, Universitätsmedizin Frankfurt, Frankfurt am Main, Deutschland
2 shared publicationsPetra Davidova
Department of Ophthalmology Goethe‐University Frankfurt Germany
2 shared publications
Latest Publications
- Open Access
- 5 March 2026
- Published by Wiley in Acta Ophthalmologica
- Vol. 104 (5) , e530-e537
Repeatability of keratometry depending on tear film osmolarity
Purpose: To determine the repeatability of keratometry and astigmatism measurements of patients depending on the tear film osmolarity using three different devices. Methods: In this study, 97 eyes of 97 patients with a mean age of 64.92 ± 12.07 years received three repeated measurements with the IOLMaster 700 (Carl Zeiss Meditec, Jena, Germany), Pentacam AXL (Oculus Optikgeräte GmbH, Wetzlar, Germany) and Galilei G6 (Ziemer Ophthalmic Systems, Port, Switzerland). After that, tear film osmolarity was obtained with the TearLab Osmolarity System (TearLab Corporation, San Diego, CA, USA) for quantification of dry eye disease. Four groups were formed depending on tear film osmolarity: group 1 (320 mOsm/L). Intraclass correlation coefficient (ICC) and vector analysis were calculated to assess the repeatability of keratometry and astigmatism measurements. Results: ICC values for keratometry were 0.957 or higher in all osmolarity groups. Highest ICC values for astigmatism were in group 1 with the Pentacam (0.986) and in group 2 (0.979), group 3 (0.951) and group 4 (0.950) with the IOL‐Master 700 respectively. Highest astigmatism ICC value for the Galilei G6 was 0.884 in group 4 and the lowest in group 3 (0.405). Vector analysis of astigmatism showed no statistically significant difference between the osmolarity groups and IOL‐Master 700 ( p = 0.947), Pentacam ( p = 0.353) and Galilei G6 ( p = 0.660). Conclusion: Tear film osmolarity showed no consistent association with the repeatability of keratometry or astigmatism measurements for the IOLMaster 700 and Pentacam AXL whereas the Galilei G6 demonstrated lower repeatability overall.
- 5 March 2026
- Published by Wiley in Acta Ophthalmologica
- Vol. 104 (5) , e530-e537
Open AccessRepeatability of keratometry depending on tear film osmolarity
Purpose: To determine the repeatability of keratometry and astigmatism measurements of patients depending on the tear film osmolarity using three different devices. Methods: In this study, 97 eyes of 97 patients with a mean age of 64.92 ± 12.07 years received three repeated measurements with the IOLMaster 700 (Carl Zeiss Meditec, Jena, Germany), Pentacam AXL (Oculus Optikgeräte GmbH, Wetzlar, Germany) and Galilei G6 (Ziemer Ophthalmic Systems, Port, Switzerland). After that, tear film osmolarity was obtained with the TearLab Osmolarity System (TearLab Corporation, San Diego, CA, USA) for quantification of dry eye disease. Four groups were formed depending on tear film osmolarity: group 1 (320 mOsm/L). Intraclass correlation coefficient (ICC) and vector analysis were calculated to assess the repeatability of keratometry and astigmatism measurements. Results: ICC values for keratometry were 0.957 or higher in all osmolarity groups. Highest ICC values for astigmatism were in group 1 with the Pentacam (0.986) and in group 2 (0.979), group 3 (0.951) and group 4 (0.950) with the IOL‐Master 700 respectively. Highest astigmatism ICC value for the Galilei G6 was 0.884 in group 4 and the lowest in group 3 (0.405). Vector analysis of astigmatism showed no statistically significant difference between the osmolarity groups and IOL‐Master 700 ( p = 0.947), Pentacam ( p = 0.353) and Galilei G6 ( p = 0.660). Conclusion: Tear film osmolarity showed no consistent association with the repeatability of keratometry or astigmatism measurements for the IOLMaster 700 and Pentacam AXL whereas the Galilei G6 demonstrated lower repeatability overall.
- 1 March 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 52 (3) , 245-252
Eight-year results of LASIK with or without combined accelerated crosslinking in highly myopic eyes
Purpose: To analyze the 8-year results of femtosecond laser–assisted in situ keratomileusis (LASIK) combined with simultaneous accelerated corneal crosslinking (LASIK-Xtra) compared with conventional LASIK (convLASIK). Setting: Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany. Design: Prospective, randomized fellow eye–controlled clinical trial. Methods: Patients who received randomized treatment with the LASIK-Xtra (30 mW/cm 2 , 90 seconds with continuous UV-A) in 1 eye and convLASIK in the fellow eye were subjected 1 year (pos1y), and 8 years postoperatively (pos8y) to subjective refraction, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), endothelial cell count (ECC), biomechanical evaluation, and tomographic examination. Results: 26 eyes (−7.07 ± 1.86 diopter [D]) from 13 patients (mean age 30.7 ± 10.4 years) were included. UDVA and CDVA were insignificantly different at pos1y and pos8y between convLASIK and LASIK-Xtra (each P > .28). The safety index at pos8y was 1.09 for convLASIK and 1.15 for LASIK-Xtra ( P = .799), and the efficacy index 0.91 and 0.94 ( P = .875), respectively. Significant myopic shift in spherical equivalent between pos1y (−0.30 ± 0.40 D) and pos8y (−0.80 ± 0.86 D) was found in the convLASIK group ( P = .018), compared the LASIK-Xtra group (−0.25 ± 0.49 D and −0.40 ± 0.86 D; P = .261), respectively. However, these refractive changes cannot be fully attributed to corneal alterations alone and may also reflect other factors. Insignificant differences in mean keratometry, corneal thickness, and ECC were found at pos8y ( P > .05). The stress–strain index was the only biomechanical parameter that was significantly higher in the LASIK-Xtra group at pos8y ( P = .034). Conclusions: After 8 years, no substantial disparities in efficacy and safety indices were observed between the 2 groups. There were no substantial differences in most of the evaluated postoperative corneal biomechanical parameters between the 2 groups. However, these findings need to be validated by further studies with larger sample sizes.
- 1 March 2026
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 52 (3) , 245-252
Eight-year results of LASIK with or without combined accelerated crosslinking in highly myopic eyes
Purpose: To analyze the 8-year results of femtosecond laser–assisted in situ keratomileusis (LASIK) combined with simultaneous accelerated corneal crosslinking (LASIK-Xtra) compared with conventional LASIK (convLASIK). Setting: Department of Ophthalmology, Goethe-University, Frankfurt am Main, Germany. Design: Prospective, randomized fellow eye–controlled clinical trial. Methods: Patients who received randomized treatment with the LASIK-Xtra (30 mW/cm 2 , 90 seconds with continuous UV-A) in 1 eye and convLASIK in the fellow eye were subjected 1 year (pos1y), and 8 years postoperatively (pos8y) to subjective refraction, uncorrected distance visual acuity (UDVA), corrected distance visual acuity (CDVA), endothelial cell count (ECC), biomechanical evaluation, and tomographic examination. Results: 26 eyes (−7.07 ± 1.86 diopter [D]) from 13 patients (mean age 30.7 ± 10.4 years) were included. UDVA and CDVA were insignificantly different at pos1y and pos8y between convLASIK and LASIK-Xtra (each P > .28). The safety index at pos8y was 1.09 for convLASIK and 1.15 for LASIK-Xtra ( P = .799), and the efficacy index 0.91 and 0.94 ( P = .875), respectively. Significant myopic shift in spherical equivalent between pos1y (−0.30 ± 0.40 D) and pos8y (−0.80 ± 0.86 D) was found in the convLASIK group ( P = .018), compared the LASIK-Xtra group (−0.25 ± 0.49 D and −0.40 ± 0.86 D; P = .261), respectively. However, these refractive changes cannot be fully attributed to corneal alterations alone and may also reflect other factors. Insignificant differences in mean keratometry, corneal thickness, and ECC were found at pos8y ( P > .05). The stress–strain index was the only biomechanical parameter that was significantly higher in the LASIK-Xtra group at pos8y ( P = .034). Conclusions: After 8 years, no substantial disparities in efficacy and safety indices were observed between the 2 groups. There were no substantial differences in most of the evaluated postoperative corneal biomechanical parameters between the 2 groups. However, these findings need to be validated by further studies with larger sample sizes.
- Open Access
- 19 February 2026
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 285, 335-342
Subjective and Objective Refraction Using Autorefraction and Two Wavefront-based Aberrometers in Extended-Depth-of-Focus and Simultaneous Vision Intraocular Lenses
- 19 February 2026
- Published by Elsevier in American Journal of Ophthalmology
- Vol. 285, 335-342
Open AccessSubjective and Objective Refraction Using Autorefraction and Two Wavefront-based Aberrometers in Extended-Depth-of-Focus and Simultaneous Vision Intraocular Lenses
- 1 December 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (12) , 1107-1114
Intraocular lens power calculation in myopic eyes undergoing bilensectomy: analysis of comparability and accuracy
Purpose: To address the calculation of intraocular lens (IOL) power in myopic eyes undergoing simultaneous anterior or posterior chamber phakic IOL (pIOL) explantation and lens extraction surgery, a procedure known as bilensectomy, in comparison with myopic eyes without pIOL (controls). Design: Retrospective analysis of comparability and accuracy. Setting: Department of Ophthalmology, Goethe-University, Frankfurt, Germany. Methods: IOLMaster 700 and Pentacam AXL were used for biometry. IOL power was calculated using the Barrett Universal II (BUII), Cooke K6, Hoffer-QST, Emmetropia Verifying Optical Formula v2.0 (EVO 2.0), Prediction Enhanced by Artificial Intelligence and output Linearization-Debellemaniere, Gatinel, and Saad (PEARL-DGS), Hill-Radial Basis Function (Hill-RBF), and Kane formulas included in the ESCRS online calculator, as well as the T2 and Ladas super formula and the SRK/T and Holladay 1 with or without Wang-Koch axial length (AL) adjustment. Results: 60 eyes (mean AL: 29.1 ± 2.06 mm) of 60 patients (mean age 57.4 ± 10.9 years) were included. 30 eyes underwent bilensectomy, and 30 served as controls. In bilensectomy eyes, Kane (0.53 diopter [D]), PEARL-DGS (0.56 D), and Hill-RBF (0.61 D) demonstrated the lowest root-mean square of the absolute error. PEARL-DGS demonstrated the highest percentage of eyes within ±0.25 D (46.7%), followed by BUII, Hill-RBF, and Kane (40.0%, each). EVO 2.0 showed a significant difference ( P = .001) in mean prediction error between the bilensectomy group and the control group. All other formulas showed no significant differences between the 2 groups (each P > .05). Conclusions: Simultaneous explantation of a pIOL does not seem to exert a considerable impact on the IOL power calculation in myopic eyes. The performance of the formulas is comparable with myopic eyes without pIOLs.
- 1 December 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (12) , 1107-1114
Intraocular lens power calculation in myopic eyes undergoing bilensectomy: analysis of comparability and accuracy
Purpose: To address the calculation of intraocular lens (IOL) power in myopic eyes undergoing simultaneous anterior or posterior chamber phakic IOL (pIOL) explantation and lens extraction surgery, a procedure known as bilensectomy, in comparison with myopic eyes without pIOL (controls). Design: Retrospective analysis of comparability and accuracy. Setting: Department of Ophthalmology, Goethe-University, Frankfurt, Germany. Methods: IOLMaster 700 and Pentacam AXL were used for biometry. IOL power was calculated using the Barrett Universal II (BUII), Cooke K6, Hoffer-QST, Emmetropia Verifying Optical Formula v2.0 (EVO 2.0), Prediction Enhanced by Artificial Intelligence and output Linearization-Debellemaniere, Gatinel, and Saad (PEARL-DGS), Hill-Radial Basis Function (Hill-RBF), and Kane formulas included in the ESCRS online calculator, as well as the T2 and Ladas super formula and the SRK/T and Holladay 1 with or without Wang-Koch axial length (AL) adjustment. Results: 60 eyes (mean AL: 29.1 ± 2.06 mm) of 60 patients (mean age 57.4 ± 10.9 years) were included. 30 eyes underwent bilensectomy, and 30 served as controls. In bilensectomy eyes, Kane (0.53 diopter [D]), PEARL-DGS (0.56 D), and Hill-RBF (0.61 D) demonstrated the lowest root-mean square of the absolute error. PEARL-DGS demonstrated the highest percentage of eyes within ±0.25 D (46.7%), followed by BUII, Hill-RBF, and Kane (40.0%, each). EVO 2.0 showed a significant difference ( P = .001) in mean prediction error between the bilensectomy group and the control group. All other formulas showed no significant differences between the 2 groups (each P > .05). Conclusions: Simultaneous explantation of a pIOL does not seem to exert a considerable impact on the IOL power calculation in myopic eyes. The performance of the formulas is comparable with myopic eyes without pIOLs.
- 1 November 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (11) , 972-978
Barrett RX tool for intraocular lens power calculation in pseudophakic eyes undergoing intraocular lens exchange
Purpose: To assess the accuracy of refraction prediction after intraocular lens (IOL) exchange using a software integrated in a Scheimpflug-based biometer. Setting: 2 tertiary referral hospitals. Design: Case series. Methods: Eyes that underwent uneventful bag-to-bag IOL exchange between 2017 and 2024 and complete preoperative and postoperative measurements were included. IOL exchange was performed by 2 experienced surgeons. IOL power was calculated using the Barrett RX formula integrated in Pentacam software, incorporating both phakic and pseudophakic biometric data and subjective refraction. Prediction errors were computed by comparing actual postoperative and predicted refractions. Moreover, an unpublished estimation formula was evaluated. Results: 25 eyes of 25 patients (mean age 60.2 ± 11.4 years) were included. Mean interval between primary IOL implantation and exchange was 25.3 ± 31.5 weeks. In 11 of 25 eyes, a different IOL model was implanted during the exchange. Using the Barrett RX formula, the mean prediction error (MPE) was 0.02 ± 0.32 diopters (D), mean absolute error (MAE) 0.27 ± 0.17 D, and median absolute error (MedAE) 0.22 D. A total of 56% and 92% of eyes were within ±0.25 D and ±0.50 D of target refraction, respectively. The conventional formula yielded a comparable MPE of –0.12 ± 0.68 D ( P = .479), but higher MAE and MedAE (0.53 ± 0.42 D and 0.40 D, P < .001), with 32% and 56% of eyes within ±0.25 D and ±0.50 D, respectively. Conclusions: The Barrett RX formula was demonstrated to be an efficacious method for calculating IOL power in eyes undergoing IOL exchange, with more than half of cases within ±0.25 D of the predicted postexchange refraction.
- 1 November 2025
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (11) , 972-978
Barrett RX tool for intraocular lens power calculation in pseudophakic eyes undergoing intraocular lens exchange
Purpose: To assess the accuracy of refraction prediction after intraocular lens (IOL) exchange using a software integrated in a Scheimpflug-based biometer. Setting: 2 tertiary referral hospitals. Design: Case series. Methods: Eyes that underwent uneventful bag-to-bag IOL exchange between 2017 and 2024 and complete preoperative and postoperative measurements were included. IOL exchange was performed by 2 experienced surgeons. IOL power was calculated using the Barrett RX formula integrated in Pentacam software, incorporating both phakic and pseudophakic biometric data and subjective refraction. Prediction errors were computed by comparing actual postoperative and predicted refractions. Moreover, an unpublished estimation formula was evaluated. Results: 25 eyes of 25 patients (mean age 60.2 ± 11.4 years) were included. Mean interval between primary IOL implantation and exchange was 25.3 ± 31.5 weeks. In 11 of 25 eyes, a different IOL model was implanted during the exchange. Using the Barrett RX formula, the mean prediction error (MPE) was 0.02 ± 0.32 diopters (D), mean absolute error (MAE) 0.27 ± 0.17 D, and median absolute error (MedAE) 0.22 D. A total of 56% and 92% of eyes were within ±0.25 D and ±0.50 D of target refraction, respectively. The conventional formula yielded a comparable MPE of –0.12 ± 0.68 D ( P = .479), but higher MAE and MedAE (0.53 ± 0.42 D and 0.40 D, P < .001), with 32% and 56% of eyes within ±0.25 D and ±0.50 D, respectively. Conclusions: The Barrett RX formula was demonstrated to be an efficacious method for calculating IOL power in eyes undergoing IOL exchange, with more than half of cases within ±0.25 D of the predicted postexchange refraction.
- Open Access
- 7 March 2025
- Published by Springer Nature in Die Ophthalmologie
- Vol. 122 (6) , 480-483
Beidseitige Optikusatrophie unklarer Genese
- 7 March 2025
- Published by Springer Nature in Die Ophthalmologie
- Vol. 122 (6) , 480-483
Open AccessBeidseitige Optikusatrophie unklarer Genese
- 24 December 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (4) , 314-322
Surgical implications in intraocular lens exchange with an open posterior capsule: a retrospective case series and review of the literature
Purpose: To determine characteristics and differences in intraocular lens (IOL) exchange between eyes with an open (OPC) and closed posterior capsule (CPC). Setting: Department of Ophthalmology, Goethe-University, Frankfurt, Germany. Design: Retrospective case series and review of literature. Methods: Charts of all cases of IOL exchange between January 2010 and May 2024 were retrospectively reviewed. Main outcome measures were indications for surgery, IOL implantation technique, and the necessity of anterior vitrectomy. MEDLINE database and Google scholar were used to identify relevant past publications. Results: We included 37 eyes of 30 patients with a mean age of 62.1 ± 10.2 years, with 16 eyes (43.2%) with OPC undergoing IOL exchange. Mean interval between IOL implantation and IOL exchange was 61.50 ± 62.00 months in the OPC group and 15.81 ± 15.03 months in the CPC group. The most common indication was optical phenomena in 18 cases (48%). In the OPC group, intraoperative anterior vitrectomy was necessary twice as often (OPC nine cases (56%) vs. CPC five cases (24%)). Bag-to-bag IOL exchange was performed in all eyes with CPC, and in 10/16 (62%) with OPC (p=0.009). Postoperative complications were seen in a total of 7/16 eyes (43.7%) with OPC and 3/21 (14.3%) with CPC (p=0.012). Conclusion: The success rate of repositioning an IOL within a bag with OPC is less than that achieved with CPC. A vitrectomy is typically required when attempting a bag-to-bag IOL exchange with an OPC. Capsulotomy should only be performed if the necessity of an IOL exchange is unlikely.
- 24 December 2024
- Published by Wolters Kluwer Health in Journal of Cataract & Refractive Surgery
- Vol. 51 (4) , 314-322
Surgical implications in intraocular lens exchange with an open posterior capsule: a retrospective case series and review of the literature
Purpose: To determine characteristics and differences in intraocular lens (IOL) exchange between eyes with an open (OPC) and closed posterior capsule (CPC). Setting: Department of Ophthalmology, Goethe-University, Frankfurt, Germany. Design: Retrospective case series and review of literature. Methods: Charts of all cases of IOL exchange between January 2010 and May 2024 were retrospectively reviewed. Main outcome measures were indications for surgery, IOL implantation technique, and the necessity of anterior vitrectomy. MEDLINE database and Google scholar were used to identify relevant past publications. Results: We included 37 eyes of 30 patients with a mean age of 62.1 ± 10.2 years, with 16 eyes (43.2%) with OPC undergoing IOL exchange. Mean interval between IOL implantation and IOL exchange was 61.50 ± 62.00 months in the OPC group and 15.81 ± 15.03 months in the CPC group. The most common indication was optical phenomena in 18 cases (48%). In the OPC group, intraoperative anterior vitrectomy was necessary twice as often (OPC nine cases (56%) vs. CPC five cases (24%)). Bag-to-bag IOL exchange was performed in all eyes with CPC, and in 10/16 (62%) with OPC (p=0.009). Postoperative complications were seen in a total of 7/16 eyes (43.7%) with OPC and 3/21 (14.3%) with CPC (p=0.012). Conclusion: The success rate of repositioning an IOL within a bag with OPC is less than that achieved with CPC. A vitrectomy is typically required when attempting a bag-to-bag IOL exchange with an OPC. Capsulotomy should only be performed if the necessity of an IOL exchange is unlikely.
- Open Access
- 21 July 2024
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 52 (8) , 833-839
Axial length adjustment in eyes with silicone oil endotamponade reduces overestimation by a swept‐source optical coherence tomography‐based biometer
Background: To assess changes in ocular biometry of the phakic eye after pars‐plana‐vitrectomy (PPV) and silicone oil (SO) endotamponade in eyes with a retinal detachment.Methods: This retrospective, consecutive case series included 72 eyes of 72 patients who underwent PPV with 5000‐centistokes SO endotamponade between July 2018 and June 2023. Pseudophakic eyes and eyes with a combined phacovitrectomy were excluded. Primary endpoints were keratometry values, anterior chamber depth (ACD), lens thickness (LT), horizontal corneal diameter (HCD), and axial length (AL) measured by swept‐source optical coherence tomography‐based biometry (IOLMaster 700) preoperatively and six weeks postoperatively. A recently described formula was used to adjust the AL (aAL) in eyes with SO endotamponade and a theoretical intraocular lens (IOL) calculation was performed.Results: The mean age was 62.1 ± 8.3 years (range: 37–85). After PPV with SO fill, there was an increase in Kmean (0.19 ± 0.51D), while ACD (0.05 ± 0.13 mm), LT (0.03 ± 0.14 mm), and HCD (0.02 ± 0.24 mm) decreased. Preoperatively, the mean AL was 25.22 ± 1.78 mm, while postoperatively the AL was overestimated by 0.12 ± 0.42 mm on average (p = 0.04). By adjusting the AL, the mean difference could be reduced to −0.002 ± 0.41 mm. The aAL resulted in a difference in the refractive outcome in eyes with an AL > 25 mm of 0.34 ± 0.10D in the IOL calculation.Conclusions: While changes in biometry after PPV with SO endotamponade in the anterior segment are clinically less relevant, a considerable overestimation of AL with IOLMaster 700 was found. We recommend the use of a recently introduced formula for adjusting AL in eyes with SO, allowing overestimation to be minimised considerably.
- 21 July 2024
- Published by Wiley in Clinical & Experimental Ophthalmology
- Vol. 52 (8) , 833-839
Open AccessAxial length adjustment in eyes with silicone oil endotamponade reduces overestimation by a swept‐source optical coherence tomography‐based biometer
Background: To assess changes in ocular biometry of the phakic eye after pars‐plana‐vitrectomy (PPV) and silicone oil (SO) endotamponade in eyes with a retinal detachment.Methods: This retrospective, consecutive case series included 72 eyes of 72 patients who underwent PPV with 5000‐centistokes SO endotamponade between July 2018 and June 2023. Pseudophakic eyes and eyes with a combined phacovitrectomy were excluded. Primary endpoints were keratometry values, anterior chamber depth (ACD), lens thickness (LT), horizontal corneal diameter (HCD), and axial length (AL) measured by swept‐source optical coherence tomography‐based biometry (IOLMaster 700) preoperatively and six weeks postoperatively. A recently described formula was used to adjust the AL (aAL) in eyes with SO endotamponade and a theoretical intraocular lens (IOL) calculation was performed.Results: The mean age was 62.1 ± 8.3 years (range: 37–85). After PPV with SO fill, there was an increase in Kmean (0.19 ± 0.51D), while ACD (0.05 ± 0.13 mm), LT (0.03 ± 0.14 mm), and HCD (0.02 ± 0.24 mm) decreased. Preoperatively, the mean AL was 25.22 ± 1.78 mm, while postoperatively the AL was overestimated by 0.12 ± 0.42 mm on average (p = 0.04). By adjusting the AL, the mean difference could be reduced to −0.002 ± 0.41 mm. The aAL resulted in a difference in the refractive outcome in eyes with an AL > 25 mm of 0.34 ± 0.10D in the IOL calculation.Conclusions: While changes in biometry after PPV with SO endotamponade in the anterior segment are clinically less relevant, a considerable overestimation of AL with IOLMaster 700 was found. We recommend the use of a recently introduced formula for adjusting AL in eyes with SO, allowing overestimation to be minimised considerably.
- Open Access
- 12 July 2024
- Published by Wiley in Acta Ophthalmologica
- Vol. 103 (1) , e31-e37
Fellow eye data for intraocular lens calculation in eyes undergoing combined phacovitrectomy
Purpose: To evaluate whether the intraocular lens (IOL) calculation of the fellow eye (FE) can be used in eyes undergoing combined phacovitrectomy.Methods: In this retrospective, consecutive case series, we enrolled patients who underwent combined phacovitrectomy with silicone oil removal and IOL implantation at the Goethe‐University. Preoperative examinations included biometry (IOLMaster 700; Carl Zeiss). We used the IOL calculation of the FE (FE group) to calculate the prediction error compared with the IOL calculation using only the axial length (AL) of the FE (AL‐FE group), as well as using the AL of the operated eye (OE group) in addition to the measurable biometric parameters. IOL calculation was performed using the Barrett Universal II formula. We compared the mean (MAE) and median absolute prediction error (MedAE) with each other. Furthermore, the number of eyes with ±0.50, ±1.00 and ±2.00 dioptres (D) deviation from the target refraction was compared.Results: In total, 79 eyes of 79 patients were included. MedAE was lowest in the OE group (0.41 D), followed by FE group (1.00 D) and AL‐FE group (1.02 D). Comparison between the AL‐FE and FE groups showed no statistically significant difference (p = 0.712). Comparing eyes within ±0.50 D of the target refraction, the OE group (63.3%) performed best, followed by the AL‐FE group (27.8%) and the FE group (26.6%).Conclusion: Our results indicate no clinically relevant difference between using the IOL calculation of the FE versus using only the AL of the FE in addition to the measurable parameters for the IOL calculation. A two‐step procedure should always be strived for.
- 12 July 2024
- Published by Wiley in Acta Ophthalmologica
- Vol. 103 (1) , e31-e37
Open AccessFellow eye data for intraocular lens calculation in eyes undergoing combined phacovitrectomy
Purpose: To evaluate whether the intraocular lens (IOL) calculation of the fellow eye (FE) can be used in eyes undergoing combined phacovitrectomy.Methods: In this retrospective, consecutive case series, we enrolled patients who underwent combined phacovitrectomy with silicone oil removal and IOL implantation at the Goethe‐University. Preoperative examinations included biometry (IOLMaster 700; Carl Zeiss). We used the IOL calculation of the FE (FE group) to calculate the prediction error compared with the IOL calculation using only the axial length (AL) of the FE (AL‐FE group), as well as using the AL of the operated eye (OE group) in addition to the measurable biometric parameters. IOL calculation was performed using the Barrett Universal II formula. We compared the mean (MAE) and median absolute prediction error (MedAE) with each other. Furthermore, the number of eyes with ±0.50, ±1.00 and ±2.00 dioptres (D) deviation from the target refraction was compared.Results: In total, 79 eyes of 79 patients were included. MedAE was lowest in the OE group (0.41 D), followed by FE group (1.00 D) and AL‐FE group (1.02 D). Comparison between the AL‐FE and FE groups showed no statistically significant difference (p = 0.712). Comparing eyes within ±0.50 D of the target refraction, the OE group (63.3%) performed best, followed by the AL‐FE group (27.8%) and the FE group (26.6%).Conclusion: Our results indicate no clinically relevant difference between using the IOL calculation of the FE versus using only the AL of the FE in addition to the measurable parameters for the IOL calculation. A two‐step procedure should always be strived for.
- Open Access
- 16 March 2022
- Published by Springer Nature in Die Ophthalmologie
- Vol. 120 (1) , 69-71
Rezidivierende immunologische intraokulare Entzündungsreaktion nach intravitrealer operativer Medikamentengabe
- 16 March 2022
- Published by Springer Nature in Die Ophthalmologie
- Vol. 120 (1) , 69-71
Open AccessRezidivierende immunologische intraokulare Entzündungsreaktion nach intravitrealer operativer Medikamentengabe