System Architecture for Actuator Management in ITER PCS

Authors:

Abstract
ITER, the largest tokamak currently under construction, will rely on a sophisticated control system to coordinate multipleplasma control tasks using tens of actuators. During the SRO phase, where ITER reaches full plasma current of 15 MAand full field and H-mode at half field and half of nominal current, there will be 40 MW of ECRH power at 9 differentmirrors, 10 MW of ICRH power on 1 antenna, 4 pellet injectors, and 60 gas valves. A key element of this system isactuator management (AM), which orchestrates actuator usage to avoid conflicts, enhance performance, and increaserobustness. Central to AM are virtual actuators, which are presented to the controllers as single entities combiningactuators with comparable effects on the plasma. Up to now, the mapping between actuators and virtual actuators hasbeen static, but future operation requires extending this concept to dynamic mappings. In addition, AM must be capableof adjusting pellet injection properties, both by varying pellet size and by modifying injector–flight tube connections.To meet these requirements, the AM architecture has been extended accordingly. This paper discusses these extensions,presents illustrative examples of their application, and provides an outlook on future developments.