A preliminary investigation into the feasibility of laser ablation U–Pb isotope ratio measurement via all‐faraday cup detection with 10 11 ‐ and 10 13 ‐Ω amplifiers on the Neoma multicollector‐inductively coupled plasma‐mass spectrometer
Open Access
- 12 June 2024
- journal article
- research article
- Published by Wiley in Rapid Communications in Mass Spectrometry
- Vol. 38 (16) , e9781
Abstract
Rationale: Signal detection for uranium–lead (U–Pb) dating of zircon is typically performed via ion counters. Here, we develop a preliminary understanding of the strengths and limitations of faraday‐cup‐based detection. Methods: A suite of zircon reference materials and the NIST‐610 glass were sampled using laser ablation followed by U–Pb isotope ratio measurement on a Neoma multicollector‐inductively coupled plasma‐mass spectrometer. Results: We were able to produce geologically accurate 207 Pb/ 206 Pb, 206 Pb/ 238 U, and 207 Pb/ 235 U ratios for the NIST‐610 glass and the zircon standards, with ages ranging from ~2.5 Ga to ~337 Ma (TanBrown A, Oracle, 91550, Mud Tank, Temora, and Plešovice). Two of the younger zircon standards examined (94‐35, ~55.6 Ma, and Fish Canyon, 28.6 Ma) yielded accurate 206 Pb/ 238 U but not 207 Pb/ 235 U or 207 Pb/ 206 Pb ratios, whereas the youngest zircon standard (Penglai, ~4.4 Ma) failed for all three ratios of interest. The accuracy and precision of the all‐faraday method are directly tied to signal intensity, with reliable data capable of being produced even when both isotopes in a ratio have signals below ~0.001 V (equivalent to ~62 500 cps on an ion counter). Conclusion: The all‐faraday cup multicollection method provides sufficient sensitivity to obtain geologically meaningful U–Pb data, with possible advantages being that laser pit depth‐dependent changes in the observed interelemental fractionation behavior may be easier to correct using a static collector configuration compared to when the ion beam is swept across a single detector while also removing the need for an interdetector‐type calibration. Further work is needed to refine the all‐faraday cup method (e.g., application of background subtraction and common Pb corrections, outlier removal, and interelement as well as down‐hole fractionation corrections), but our initial results demonstrate that the faraday detector method has sufficient sensitivity to warrant further study.Keywords
Funding Information
- U.S. Department of Energy (DE‐AC05‐00OR22725)
This publication has 26 references indexed in Scilit:
- Synchronous formation of the ‘forearc’ Bay of Islands ophiolite and its basal high-temperature metamorphic sole constrained by U–Pb zircon agesGeoscience Frontiers, 2023
- Multicollector Inductively Coupled Plasma–Mass Spectrometry with 1013 Ω Faraday Cup Amplifiers for Ultrasensitive Mg Isotopic Analysis of Cerebrospinal Fluid MicrosamplesAnalytical Chemistry, 2020
- Evaluating downhole fractionation corrections in LA-ICP-MS U-Pb zircon geochronologyChemical Geology, 2018
- U–Th–Pb zircon geochronology by ID-TIMS, SIMS, and laser ablation ICP-MS: Recipes, interpretations, and opportunitiesChemical Geology, 2015
- A new method integrating high-precision U–Pb geochronology with zircon trace element analysis (U–Pb TIMS-TEA)Geochimica et Cosmochimica Acta, 2010
- Laser ablation coupled with ICP-MS applied to U–Pb zircon geochronology: A review of recent advancesGondwana Research, 2008
- Plešovice zircon — A new natural reference material for U–Pb and Hf isotopic microanalysisChemical Geology, 2008
- 40Ar/39Ar and U–Pb dating of the Fish Canyon magmatic system, San Juan Volcanic field, Colorado: Evidence for an extended crystallization historyChemical Geology, 2007
- Reassessing the uranium decay constants for geochronology using ID-TIMS U–Pb dataGeochimica et Cosmochimica Acta, 2006
- Zircon U–Pb chemical abrasion (“CA-TIMS”) method: Combined annealing and multi-step partial dissolution analysis for improved precision and accuracy of zircon agesChemical Geology, 2005