NZNasser A. Zirakparvar

Nasser A. Zirakparvar

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nasser A. Zirakparvar has a total of 84 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Single particle – MC-ICP-MS for isotopic analysis of uranium particles

    by Benjamin T. Manard, Daniel R. Dunlap, Sarah E. Szakas, Jordan S. Stanberry, Matt Darnell, N. Alex Zirakparvar, Cole R. Hexel, Shawna K. Tazik, Rachel A. Bergin, Brian W. Ticknor, et al.

    Single particle – multi-collector – inductively coupled plasma – mass spectrometry (SP-MC-ICP-MS) was employed to measure 1 µm U 3 O 8 particles to determine their individual isotopic compositions of 234 U/ 238 U, 235 U/ 238 U, and 236 U/ 238 U.

  • A case study on the use of carbon sticky tabs for microbeam uranium isotope measurement with an emphasis on understanding the influence of subtle variations in substrate composition

    by N. Alex Zirakparvar, Benjamin T. Manard, Brian Monteleone, Hunter Andrews, Brian Ticknor, Shalina Metzger, Daniel R. Dunlap, Toya Beiswenger, Cole R. Hexel

  • Open Access

    Round Robin Analysis of Uranium Isotopics on Cotton Swipes Measured Using Microextraction-Based Sampling Versus Conventional Bulk Analysis

    by Shalina C. Metzger, Veronica C. Bradley, Brian W. Ticknor, Cole R. Hexel, Melissa L. Adkisson, N. Alex Zirakparvar, Daniel R. Dunlap, R. Kenneth Marcus, Joseph V. Goodwin, Hunter B. Andrews, et al.

    A comparison of microextraction sampling methods to directly analyze uranium isotopics on cotton swipes was performed concurrently with traditional bulk-processing methods. For the microextraction sampling approach, two different detection platforms were evaluated, a quadrupole-based inductively coupled plasma mass spectrometer (ICP-MS) and the liquid sampling-atmospheric pressure glow discharge (LS-APGD) coupled to an Orbitrap mass spectrometer. Results presented from this innovative sampling approach (i.e., microextraction) are compared with a more traditional approach employed for analysis of cotton-based environmental swipes, namely bulk ashing/digestion, separation, and subsequent analysis by high-precision multi-collector ICP-MS. Overall, the microextraction approach proved to be a reliable and accurate means to determine isotopic ratios of uranium collected on cotton swipes. The ICP-MS-based detection had relative standard deviations of 235 U/ 238 U ratios, in comparison to the expected values, was 234 U/ 238 U and 236 U/ 238 U).

  • Preliminary Insights Into the Feasibility of Determining the Purification Date of Enriched Uranium by Direct Measurement of the 230 Th/ 234 U Ratio Using an All‐Faraday Detector Configuration on the Neoma MC‐ICP‐MS

    by N. Alex Zirakparvar, Benjamin T. Manard, Daniel R. Dunlap, Matt Darnell, Debra Bostick, Brian Ticknor, Cole R. Hexel

    Rationale: Mass spectrometric measurement of the 230 Th /234 U ratio to calculate the purification age of enriched uranium is typically conducted via a combination of ion counters and faraday detectors, thus requiring an inter‐detector calibration scheme. Our aim is to understand whether the pursuit of a simplified measurement scheme involving only faraday detectors is feasible. Methods: We investigate the possibility of determining U‐Th model ages for two enriched uranium standards (NBL U630 and U850) by direct measurement of the 230 Th/ 234 U ratio (without chromatographic separation or isotope dilution) on a ThermoFisher Scientific Neoma MC‐ICP‐MS utilizing both solution and laser ablation (LA)‐based sampling techniques and an all‐faraday detector configuration. Results: For the solution mode analyses conducted on aliquots containing sub μg/mL total U, we produce composite average 230 Th/ 234 U model dates of May 19, 1988 (± 351 days), and March 26, 1961 (± 2.5 years) using the directly measured 230 Th/ 234 U ratios for the NBL U630 and U850 uranium standards, which have certified purification dates of June 6, 1988 (± 190 days), and December 31, 1957 (± 36.5 days), respectively. The ages produced by LA‐based sampling of dried residues of the same standards deposited onto cotton TexWipes are less accurate and of poorer precision (June 23, 2004 ± 8.7 years for U630 and December 21, 1965 ± 7.9 years for U850) but still yield meaningful information in regards to the purification date. Conclusions: We believe that further refinement of the all faraday detector measurement approach to include development of a more robust Th/U relative sensitivity factor determination, signal cutoff selection, and data processing protocols will allow for this approach to be confidently applied to enriched uranium materials with unknown purification histories. Potential advantages of the method include the reduced sample handling and infrastructure requirements as well as the ability to simultaneously generate a broad picture of the uranium isotopic composition in tandem with the U‐Th age determination.


  • Open Access

    Particle signal considerations for isotope ratio analysis with single particle multi-collector inductively coupled plasma mass spectrometry

    by Sarah E. Szakas, Jordan S. Stanberry, N. Alex Zirakparvar, Hunter B. Andrews, Daniel R. Dunlap, Matt Darnell, Brian W. Ticknor, Lorianne Rebecca Shultz-Johnson, Shawna K. Tazik, Benjamin T. Manard

    An investigation of data processing considerations for single particle-multi-collector-inductively coupled plasma-mass spectrometry was conducted for improved precision and accuracy.


  • Open Access

    A preliminary investigation into the feasibility of laser ablation U–Pb isotope ratio measurement via all‐faraday cup detection with 10 11 ‐ and 10 13 ‐Ω amplifiers on the Neoma multicollector‐inductively coupled plasma‐mass spectrometer

    by N. Alex Zirakparvar, Benjamin T. Manard, Daniel Dunlap, Cole R. Hexel

    Rationale: Signal detection for uranium–lead (U–Pb) dating of zircon is typically performed via ion counters. Here, we develop a preliminary understanding of the strengths and limitations of faraday‐cup‐based detection. Methods: A suite of zircon reference materials and the NIST‐610 glass were sampled using laser ablation followed by U–Pb isotope ratio measurement on a Neoma multicollector‐inductively coupled plasma‐mass spectrometer. Results: We were able to produce geologically accurate 207 Pb/ 206 Pb, 206 Pb/ 238 U, and 207 Pb/ 235 U ratios for the NIST‐610 glass and the zircon standards, with ages ranging from ~2.5 Ga to ~337 Ma (TanBrown A, Oracle, 91550, Mud Tank, Temora, and Plešovice). Two of the younger zircon standards examined (94‐35, ~55.6 Ma, and Fish Canyon, 28.6 Ma) yielded accurate 206 Pb/ 238 U but not 207 Pb/ 235 U or 207 Pb/ 206 Pb ratios, whereas the youngest zircon standard (Penglai, ~4.4 Ma) failed for all three ratios of interest. The accuracy and precision of the all‐faraday method are directly tied to signal intensity, with reliable data capable of being produced even when both isotopes in a ratio have signals below ~0.001 V (equivalent to ~62 500 cps on an ion counter). Conclusion: The all‐faraday cup multicollection method provides sufficient sensitivity to obtain geologically meaningful U–Pb data, with possible advantages being that laser pit depth‐dependent changes in the observed interelemental fractionation behavior may be easier to correct using a static collector configuration compared to when the ion beam is swept across a single detector while also removing the need for an interdetector‐type calibration. Further work is needed to refine the all‐faraday cup method (e.g., application of background subtraction and common Pb corrections, outlier removal, and interelement as well as down‐hole fractionation corrections), but our initial results demonstrate that the faraday detector method has sufficient sensitivity to warrant further study.


  • Open Access

    Mapping of uranium particles on J-type swipes with microextraction-ICP-MS

    by Veronica C. Bradley, Jacob Burleson, Hunter B. Andrews, Cyril V. Thompson, Tyler L. Spano, Daniel R. Dunlap, N. Alex Zirakparvar, Brian W. Ticknor, Cole R. Hexel, Benjamin T. Manard

    A microextraction sampling system coupled to a quadrupole inductively coupled plasma-mass spectrometer (ICP-MS) was utilized to spatially discern uranium particles, isotopically, on a cellulose-based swipe material ( i.e. , J-type swipe).


  • Open Access

    Analytical Report for Nuclear Regulatory Commission High Burnup Fuel Specimens

    by Tamara {Tammy} Keever, Usdoe, Doug Canaan, Jordan Couch, Jeffrey {Jeff} S. Delashmitt, Joseph {Joe} M. Giaquinto, Cole Hexel, Germina Procop, John Partridge, Benjamin Roach, et al.

    The U.S. Department of Energy's Office of Scientific and Technical Information


  • Open Access

    Investigation of the 176Yb Interference Correction during Determination of the 176Hf/177Hf Ratio by Laser Ablation and Solution Analysis on the Neoma MC-ICP-MS

    by Nasser A. Zirakparvar, Benjamin T. Manard, Cole R. Hexel, Daniel R. Dunlap

    We utilized the Neoma™, a recently released MC-ICP-MS platform offered by ThermoFisher Scientific, to assess the behavior of the Lu-Yb-Hf system during laser ablation analyses of various zircon standards as well as solution-based analyses of the JMC-475 Hf standard doped with varying quantities of Yb and Lu. The primary goal of this work was to characterize the behavior of the Yb interference correction on the Neoma™ platform since this is one of the biggest issues in the Hf isotope analysis community and because the Neoma™ platform will supplant the Neptune™ series instrument. During laser ablation analysis, we found that the overall data quality scales proportionally with the total Hf signal intensity, with higher signal analyses producing extremely accurate (within 1 εHf unit) and precise (sub εHf unit within-run standard errors) data. At low Yb signals (173Yb), we were not able to produce an accurate internal Yb mass bias factor. However, utilizing an empirical approach allows for the application of session-specific relationships between the Yb and Hf mass bias factors, determined by analysis of standards of varying Yb content, to produce accurate εHf values from zircons with higher Yb/Hf ratios even where the total Hf signal intensity is relatively low. Similar behavior was observed in the solution analyses. Lastly, while the behavior of the Yb interference correction on the Neoma™ platform appears comparable to the Neptune™ series MC-ICP-MS, further work will help refine the understanding of the controls on mass bias behavior, oxide formation, session-to-session stability, etc.


  • Direct analysis of cotton swipes for plutonium isotope determination by microextraction-ICP-MS

    by Benjamin T. Manard, Shalina C. Metzger, Kayron T. Rogers, Brian W. Ticknor, N. Alex Zirakparvar, Benjamin D. Roach, Debra A. Bostick, Cole R. Hexel

    This study demonstrates a method for determining the isotopic composition of low-level (sub-pg) plutonium (Pu) directly from a cotton swipe. Environmental sample (ES) swipes are routinely employed as a tool for monitoring activities in nuclear facilities. Traditional ES swipe analysis, as employed in nuclear safeguards, utilizes laborious ashing, digestion, and chemical separation procedures prior to mass spectrometric (MS) analysis. Here, an innovative sample introduction technique employing a microextraction probe to extract Pu directly from the swipe surface is described. The microextraction probe lowers onto the swipe surface, seals on a small area (8 mm2), and delivers solvent (2% HNO3) to extract actinide material that may be present. The extracted analyte is subsequently directed into a sector field inductively coupled plasma (ICP)-MS for isotope ratio determination. This microextraction-ICP-MS method successfully determined the isotopic composition (240Pu/239Pu and 242Pu/239Pu) of three Pu certified reference materials (CRM 136, 137, and 138) that were deposited (1 pg) onto ES swipes. The percent relative difference from the certified value, uncorrected for instrumental fractionation, was 240Pu/239Pu ratio on all three CRMs and 242Pu/239Pu ratio on CRM 136 and 138. The percent relative standard deviation, an estimate of the sample-to-sample isotopic precision, was 240Pu/239Pu and 242Pu/239Pu. Method limits of detection were determined, based on measurements of an enriched 244Pu material, to be ∼7 fg. Additionally, a mixed uranium (U) and Pu deposition was made to determine the method's ability to simultaneously extract U and Pu and determine the isotopic composition of both analytes.