A Neural network (NN) is a promising tool for the tomographic inversion of the ionosphere. However, existing research has adopted an unbalanced cost function for training purposes and a preset image for constraint purposes, resulting in the output image being dominated by measurements. To address these problems, we proposed an NN-based tomographic model with a balance cost function and a dynamic correction process (BCDC) for ionosphere inversion. The cost function is composed of two balance terms corresponding to the measurements and the selected constraints, respectively. The produced image in the forward process of the NN is corrected dynamically by fitting each vertical profile with orthogonal basis functions (EOFs) and the Chapman function and then by smoothing the voxels of each layer with a moving window approach horizontally. The corrected image is then used to calculate the slant total electron content (STEC) parameter, which is further translated into the term of the cost for the vertical and horizontal constraints. Experiments were carried out to validate the BCDC method and compared with a recently developed tomographic method and the international reference ionosphere (IRI) model. Results show that the parameters derived from the BCDC model demonstrate good consistency with the observations. Comparing with the reference methods, the BCDC method performs better in the validations of vertical profiles, F2 layer peak density (NmF2), STEC parameter and vertical total electron content map. Further analysis also shows that a balance cost function is of benefit to achieve an image of better quality.Keywords
Funding Information
- National Key Research and Development Program of China (2018YFB0505304)
- National Natural Science Foundation of China (41771416)
This publication has 28 references indexed in Scilit:
- Simultaneous multiplicative column-normalized method (SMART) for 3-D ionosphere tomography in comparison to other algebraic methodsAnnales Geophysicae, 2016
- Three‐dimensional GPS ionospheric tomography over Japan using constrained least squaresJournal of Geophysical Research: Space Physics, 2014
- Online, automatic, near‐real time estimation of GPS‐TEC: IONOLAB‐TECSpace Weather, 2013
- Numerical validations of neural‐network‐based ionospheric tomography for disturbed ionospheric conditions and sparse dataRadio Science, 2011
- Tomographic reconstruction of ionospheric electron density based on constrained algebraic reconstruction techniqueGPS Solutions, 2010
- Three‐dimensional ionospheric tomography using observation data of GPS ground receivers and ionosonde by neural networkJournal of Geophysical Research, 2005
- Improving the vertical resolution of ionospheric tomography with GPS OccultationsGeophysical Research Letters, 1997
- Application of computerized tomography to the investigation of ionospheric structuresRadio Science, 1990
- Expansion of ionospheric characteristics fields in empirical orthogonal functionsAdvances In Space Research, 1988
- The absorption and dissociative or ionizing effect of monochromatic radiation in an atmosphere on a rotating earthProceedings of the Physical Society (1926-1948), 1931