Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Haoyu Zhu has a total of 9 co-authors. Here are the top co-authors by number of shared publications:

  • Jieqing Yu

    School of Environmental Science and Spatial Informatics, China University of Mining and Technology, Xuzhou, China

    2 shared publications
  • Lixin Wu

    School of Geosciences and Info-Physics, Central South University, Changsha 410083, China

    1 shared publication
  • Yanyu Zhu

    School of Environmental Science and Spatial Informatics, China University of Mining and Technology, Xuzhou, China

    1 shared publication
  • Yanyu Zhu

    School of Environmental Science and Spatial Informatics, China University of Mining and Technology, Xuzhou 221116, China

    1 shared publication
  • Yaqin Sun

    School of Environmental Science and Spatial Informatics, China University of Mining and Technology, Xuzhou, China

    1 shared publication
  • Yingqi Huang

    School of Environmental Science and Spatial Informatics, China University of Mining and Technology, Xuzhou, China

    1 shared publication

Latest Publications

  • Dual Empirical Orthogonal Functions Restrained Tomographic Model for Ionosphere Imaging

    by Jieqing Yu, Yanyu Zhu, Yuchen Dai, Haoyu Zhu, Yingqi Huang, Lixin Wu, Yaqin Sun

    Extra constraints are always brought into an ionosphere tomographic model to strengthen its robustness. However, existent models using the constraints either show a weak restriction, amplifying the model’s uncertainties, or demonstrate a strong restriction, decreasing the model’s flexibility. Empirical Orthogonal Function (EOF), as a kind of basis function and generally being extracted from a prior dataset, is an ideal constraint for the tomographic model. By using EOFs as the vertical and slant constraints of the tomographic model, a dual-EOFs restrained tomographic model (DERT) is proposed. In DERT, a smooth constraint, conducted by a moving window process, is firstly imposed, and then a vertical constraint and a slant constraint, which are carried out by fitting the estimated vertical and slant profiles with their dominant EOFs via a least square method, are appended. To reduce the impacts of the errors of the slant total electron content (STEC) measurements on the processes of moving window and least square fit, an algorithm that can reject abnormal STEC values is employed before the two processes. Validations Tests are conducted to validate the DERT and compare it with the Slepian method and the IRI-2016 model. Results show that DERT outperforms the reference methods in aspects of vertical profiles, F2 layer peak density (foF2), STEC measurement and vertical total electron content (VTEC). The root mean square errors (RMSE) improvements over the Slepian method are 14.17%, 0.47%, 16.24% and 40.46% (IGS map as the truth), respectively.


  • Open Access

    Ionosphere Tomographic Model Based on Neural Network with Balance Cost and Dynamic Correction Using Multi-Constraints

    by Haoyu Zhu, Jieqing Yu, Yuchen Dai, Yanyu Zhu, Yingqi Huang

    A Neural network (NN) is a promising tool for the tomographic inversion of the ionosphere. However, existing research has adopted an unbalanced cost function for training purposes and a preset image for constraint purposes, resulting in the output image being dominated by measurements. To address these problems, we proposed an NN-based tomographic model with a balance cost function and a dynamic correction process (BCDC) for ionosphere inversion. The cost function is composed of two balance terms corresponding to the measurements and the selected constraints, respectively. The produced image in the forward process of the NN is corrected dynamically by fitting each vertical profile with orthogonal basis functions (EOFs) and the Chapman function and then by smoothing the voxels of each layer with a moving window approach horizontally. The corrected image is then used to calculate the slant total electron content (STEC) parameter, which is further translated into the term of the cost for the vertical and horizontal constraints. Experiments were carried out to validate the BCDC method and compared with a recently developed tomographic method and the international reference ionosphere (IRI) model. Results show that the parameters derived from the BCDC model demonstrate good consistency with the observations. Comparing with the reference methods, the BCDC method performs better in the validations of vertical profiles, F2 layer peak density (NmF2), STEC parameter and vertical total electron content map. Further analysis also shows that a balance cost function is of benefit to achieve an image of better quality.