Bromine and iodine determination in active pharmaceutical ingredients by ICP-MS
- 19 September 2012
- journal article
- research article
- Published by Royal Society of Chemistry (RSC) in Journal of Analytical Atomic Spectrometry
- Vol. 27 (11) , 1889-1894
Abstract
A method based on microwave-induced combustion (MIC) was applied for digestion of active pharmaceutical ingredients (APIs) and subsequent determination of bromine and iodine by inductively coupled plasma mass spectrometry (ICP-MS). Ten APIs including amoxicillin, atenolol, clavulanic acid, clonazepan, diltiazem, haloperidol, imipramine, nimesulide, propranolol and sodium diclofenac were decomposed by MIC. Combustion of 500 mg of each API was possible in less than 30 s using 20 bars of oxygen as initial pressure. A single and diluted solution (50 mmol L−1 (NH4)2CO3) was used for the absorption of both analytes and a reflux step of 5 min was applied to improve analyte recoveries. Final digests were suitable to Br and I determination by ICP-MS. Accuracy was evaluated using certified reference materials and agreement better than 95 and 97% for Br and I was obtained, respectively. Results were also compared with those obtained by ion chromatography (IC). The carbon content in digests obtained after decomposition was lower than 500 mg L−1 avoiding interferences in the determination step for both techniques. With the use of MIC, up to eight samples could be processed simultaneously and only diluted solutions are required, minimizing reagent consumption and waste generation. The limits of detection for Br and I by ICP-MS were 0.02 and 0.001 μg g−1, respectively, that were considered suitable for the determination of these elements in the investigated active pharmaceutical ingredients.Keywords
This publication has 30 references indexed in Scilit:
- REVIEW: Iodine Determination by Inductively Coupled Plasma SpectrometryApplied Spectroscopy Reviews, 2010
- Genotoxic Impurities: From Structural Alerts to QualificationOrganic Process Research & Development, 2010
- Recent advances in trace analysis of pharmaceutical genotoxic impuritiesJournal of Pharmaceutical and Biomedical Analysis, 2010
- Chlorine and sulfur determination in extra-heavy crude oil by inductively coupled plasma optical emission spectrometry after microwave-induced combustionSpectrochimica Acta Part B: Atomic Spectroscopy, 2009
- Control and analysis of alkyl and benzyl halides and other related reactive organohalides as potential genotoxic impurities in active pharmaceutical ingredients (APIs)Journal of Pharmaceutical and Biomedical Analysis, 2008
- Isolation, structural elucidation and characterization of impurities in CefdinirJournal of Pharmaceutical and Biomedical Analysis, 2007
- Pharmaceutical impurities: Regulatory perspective for Abbreviated New Drug Applications☆☆☆Advanced Drug Delivery Reviews, 2007
- Determination of halogens in organic compounds by high resolution inductively coupled plasma mass spectrometry (HR-ICP-MS)Journal of Analytical Atomic Spectrometry, 2003
- Determination of residual carbon by inductively-coupled plasma optical emission spectrometry with axial and radial view configurationsAnalytica Chimica Acta, 2001
- Determination of bromine traces in sodium diclofenac, using X-ray fluorescence spectroscopyJournal of Pharmaceutical and Biomedical Analysis, 1990