A retrospective study on the crestal bone loss associated with different implant surfaces in chronic periodontitis patients under maintenance
- 17 April 2018
- journal article
- research article
- Published by Wiley in Clinical Oral Implants Research
- Vol. 29 (6) , 557-567
Abstract
Objective: To analyze retrospectively interproximal crestal bone loss (CBL) on external‐hex “non‐identical” (NI) dental implants with different surface topography, when placed in the same intra‐oral location in patients with a history of chronic periodontitis following maintenance care.Material and methods: The patient population consisted of 206 consecutive patients with a history of chronic periodontitis who underwent implant surgery between 2007 and 2010; 755 NI implants with different implant surfaces were placed at posterior mandibular sites: 72 machined, 145 acid‐etched/machined (hybrid), and 538 anodized. Crestal bone loss measurements were carried out analyzing the calibrated digital X‐rays taken at 1‐year intervals as part of the maintenance program, being the time of this retrospective examination from 1 to 3 years.Results: At 3 years (51 patients), the mean CBL was 1.36/1.35 mm at implant/patient level (range: 0–6 mm). A higher CBL was observed at anodized surface implants, when compared to machined and hybrid implants, being the mean CBL 1.48, 0.96, and 0.77 mm, respectively (p = .005). CBL between 2 and 3.9 mm was found in 10.6% of the implants at 3 years (95% CI: 6%–15%), ≥4 mm in 5% (95% CI: 2%–8%). Anodized surface implants had CBL >2 mm at 2 years of 9% (95% CI: 6%–12%) and at 3 years of 18% (95% CI: 12%–24%), which were 2.5 times higher than hybrid implants with 3.6% (95% CI: 0.8%–4%) and 7.4% (95% CI: 0%–17%), respectively.Conclusions: A higher CBL was observed in the anodized surface implants group, when compared to the hybrid implants group in patients with a history of chronic periodontitis followed during 1–3 years.Keywords
This publication has 48 references indexed in Scilit:
- Peri‐implant tissue destruction. The Third EAO Consensus Conference 2012Clinical Oral Implants Research, 2012
- The epidemiology of peri‐implantitisClinical Oral Implants Research, 2012
- Implants with an Oxidized Surface Placed Predominately in Soft Bone Quality and Subjected to Immediate Occlusal Loading: Results from a 7‐Year Clinical Follow‐UpClinical Implant Dentistry and Related Research, 2011
- Current challenges in successful rehabilitation with oral implantsJournal of Oral Rehabilitation, 2010
- Rehabilitation of Edentulous Mandibles by Means of Five TiUnite™ Implants After One‐Stage Surgery: A 1‐Year Retrospective Study of 90 PatientsClinical Implant Dentistry and Related Research, 2008
- A Prospective Multicenter Clinical Trial Comparing One‐ and Two‐Stage Titanium Screw‐Shaped Fixtures with One‐Stage Plasma‐Sprayed Solid‐Screw FixturesClinical Implant Dentistry and Related Research, 2000
- Changes in the prevalence of residual pockets and tooth loss in treated periodontal patients during a supportive maintenance care programJournal of Clinical Periodontology, 1998
- Mk II: the self‐tapping Brånemark implant: 5‐year results of a prospective 3‐center studyClinical Oral Implants Research, 1997
- Bleeding on probing. A parameter for monitoring periodontal conditions in clinical practiceJournal of Clinical Periodontology, 1994
- The Plaque Control RecordJournal of Periodontology, 1972