Alberto Sicilia
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Alberto Sicilia has a total of 43 co-authors. Here are the top co-authors by number of shared publications:
- Mariano Sanz
ETEP (Etiology and Therapy of Periodontal and Peri‐implant Diseases) Research Group University Complutense of Madrid Madrid Spain
3 shared publications Carmen Mallo
Section of Periodontology Faculty of Health Sciences University Clinic of Odontology University of Oviedo Oviedo Spain
2 shared publicationsLuis Gallego
Section of Periodontology Faculty of Health Sciences University Clinic of Odontology University of Oviedo Oviedo Spain
2 shared publications- Marc Quirynen
Department of Oral Health Sciences, Periodontology, KU Leuven & Dentistry University Hospitals Leuven Leuven Belgium
2 shared publications Pelayo Sicilia
Section of Periodontology Faculty of Health Sciences University Clinic of Odontology University of Oviedo Oviedo Spain
2 shared publicationsSusana Cuesta
Section of Periodontology Faculty of Health Sciences University Clinic of Odontology University of Oviedo Oviedo Spain
2 shared publications
Latest Publications
- 19 November 2020
- Published by Wiley in Clinical Oral Implants Research
- Vol. 32 (1) , 88-99
Crestal bone loss associated with different implant surfaces in the posterior mandible in patients with a history of periodontitis. A retrospective study
Objective: To retrospectively assess the interproximal bone loss (CBL) in external hexagon implants (EHI), with different surface micro‐topography, placed in the posterior mandible in patients with a history of periodontitis undergoing supportive periodontal care.Material and methods: 268 consecutive patients received 755 EHI implants in the mandibular molar region between 2007 and 2015 with the following surface characteristics: 72 turned, 145 hybrids (double acid‐etched/turned), and 538 anodized. CBL was yearly evaluated by analysing calibrated digital periapical radiographs, with a follow‐up of 1–6 years. Data on implant survival were also calculated.Results: At 6 years (53 patients), the mean CBL was 1.34/1.42 mm at patient/implant level, respectively (range: 0–5.2 mm). Significantly higher CBL was detected in anodized implants than in turned and hybrid implants (1.92/1.46/1.02 mm) (p < .01). The maximum CBL values were found in 2 anodized implants at 4 years (6.3 and 8.1 mm). CBL ≥2 mm was detected in 18% of implants at 3 years and 35% at 6 (p < 2.2 × 10−16), this prevalence being 2.6 times higher in the anodized than in the hybrid and turned group (40%/15.6%, p < .0094). At 6 years, 25 anodized implants presented CBL ≥3 mm (18%). 6 anodized implants (5 patients) were removed between 4 and 5 years.Conclusion: A significant higher CBL was observed in anodized, compared to hybrid and turned implants, when placed in the mandibular molar region of periodontal patients, with a follow‐up of 1 to 6 years.
- 19 November 2020
- Published by Wiley in Clinical Oral Implants Research
- Vol. 32 (1) , 88-99
Crestal bone loss associated with different implant surfaces in the posterior mandible in patients with a history of periodontitis. A retrospective study
Objective: To retrospectively assess the interproximal bone loss (CBL) in external hexagon implants (EHI), with different surface micro‐topography, placed in the posterior mandible in patients with a history of periodontitis undergoing supportive periodontal care.Material and methods: 268 consecutive patients received 755 EHI implants in the mandibular molar region between 2007 and 2015 with the following surface characteristics: 72 turned, 145 hybrids (double acid‐etched/turned), and 538 anodized. CBL was yearly evaluated by analysing calibrated digital periapical radiographs, with a follow‐up of 1–6 years. Data on implant survival were also calculated.Results: At 6 years (53 patients), the mean CBL was 1.34/1.42 mm at patient/implant level, respectively (range: 0–5.2 mm). Significantly higher CBL was detected in anodized implants than in turned and hybrid implants (1.92/1.46/1.02 mm) (p < .01). The maximum CBL values were found in 2 anodized implants at 4 years (6.3 and 8.1 mm). CBL ≥2 mm was detected in 18% of implants at 3 years and 35% at 6 (p < 2.2 × 10−16), this prevalence being 2.6 times higher in the anodized than in the hybrid and turned group (40%/15.6%, p < .0094). At 6 years, 25 anodized implants presented CBL ≥3 mm (18%). 6 anodized implants (5 patients) were removed between 4 and 5 years.Conclusion: A significant higher CBL was observed in anodized, compared to hybrid and turned implants, when placed in the mandibular molar region of periodontal patients, with a follow‐up of 1 to 6 years.
- 22 November 2019
- Published by Wiley in Clinical Oral Implants Research
- Vol. 31 (3) , 229-238
Flapless immediate implant placement and provisionalization in periodontal patients: A retrospective consecutive case‐series study of single‐tooth sites with dehiscence‐type osseous defects
Objective: To assess the clinical outcomes of flapless, immediate implant placement with simultaneous augmentation of dehiscence defects and immediate provisional restoration.Materials and Methods: Retrospective evaluation of 40 periodontal patients who received a flapless immediate implant for single‐tooth replacement with simultaneous augmentation of dehiscence defects and immediate provisional restoration, at follow‐up periods ranging from 1 year minimum to 7 years maximum. Dehiscence defects were augmented using autogenous bone grafts and/or deproteinized bovine bone mineral, and autogenous or allogeneic connective tissue grafts. The following aspects were evaluated: clinical success (Clinical Oral Implants Research, 8, 1997, 161), crestal bone loss (calibrated digital periapical X‐rays) and aesthetics (Pink Esthetic Score, PES). Additionally, a questionnaire was devised to obtain patient's subjective evaluation.Results: A 98.3% (95% CI: 91%–99%) success rate was observed. At 8 weeks, mean bone loss was 0.47 mm (n = 39); between 8 weeks and 1 year, this va lue attained 0.24 mm and between years 1 and 5 years 0.06 mm (n = 9). The evaluated PES in 37 single‐tooth implants was 12.4, with PES = 7 (aesthetic failures) in two cases, and aesthetic outcomes were excellent (PES ≥ 12) in 29 cases (78.4%). When compared with the contralateral tooth, a recession under 1 mm was observed in 78% of cases. The patient's subjective satisfaction value ranged from 98% to 100%.Conclusion: This type of minimally invasive treatment of alveoli with buccal plate deficiencies delivers, in the hands of an experienced clinician, a high clinical and aesthetic success percentage being rated by patients as satisfactory. Clinicians should be aware that 1–2 mm comparative recession could be observed.
- 22 November 2019
- Published by Wiley in Clinical Oral Implants Research
- Vol. 31 (3) , 229-238
Flapless immediate implant placement and provisionalization in periodontal patients: A retrospective consecutive case‐series study of single‐tooth sites with dehiscence‐type osseous defects
Objective: To assess the clinical outcomes of flapless, immediate implant placement with simultaneous augmentation of dehiscence defects and immediate provisional restoration.Materials and Methods: Retrospective evaluation of 40 periodontal patients who received a flapless immediate implant for single‐tooth replacement with simultaneous augmentation of dehiscence defects and immediate provisional restoration, at follow‐up periods ranging from 1 year minimum to 7 years maximum. Dehiscence defects were augmented using autogenous bone grafts and/or deproteinized bovine bone mineral, and autogenous or allogeneic connective tissue grafts. The following aspects were evaluated: clinical success (Clinical Oral Implants Research, 8, 1997, 161), crestal bone loss (calibrated digital periapical X‐rays) and aesthetics (Pink Esthetic Score, PES). Additionally, a questionnaire was devised to obtain patient's subjective evaluation.Results: A 98.3% (95% CI: 91%–99%) success rate was observed. At 8 weeks, mean bone loss was 0.47 mm (n = 39); between 8 weeks and 1 year, this va lue attained 0.24 mm and between years 1 and 5 years 0.06 mm (n = 9). The evaluated PES in 37 single‐tooth implants was 12.4, with PES = 7 (aesthetic failures) in two cases, and aesthetic outcomes were excellent (PES ≥ 12) in 29 cases (78.4%). When compared with the contralateral tooth, a recession under 1 mm was observed in 78% of cases. The patient's subjective satisfaction value ranged from 98% to 100%.Conclusion: This type of minimally invasive treatment of alveoli with buccal plate deficiencies delivers, in the hands of an experienced clinician, a high clinical and aesthetic success percentage being rated by patients as satisfactory. Clinicians should be aware that 1–2 mm comparative recession could be observed.
- Open Access
- 10 October 2018
- Published by Wiley in Clinical Oral Implants Research
- Vol. 29 (S18) , 93-99
Drugs and diseases: Summary and consensus statements of group 1. The 5thEAO Consensus Conference 2018
Objectives: The task of this working group was to update the knowledge about the use of drugs and biologicals affecting healing of soft tissue and bone during implant treatment or procedures associated with it. Moreover, the impact of titanium particles and biocorrosion on complications and implant survival has been analysed.Materials and Methods: The literature in the areas of interest (platelet concentrates, antiresorptive drugs as well as implant–host interaction) was screened using systematic reviews for the former two areas, whereas a narrative critical review was performed for the latter topic. Two manuscripts on platelet concentrates, one manuscript on antiresorptive drugs and one manuscript on the effects of biocorrosion, were presented for group analysis with subsequent discussion in the plenum and final consensus approval.Results: Results and conclusions of the individual reviews of the three topics are presented in the respective papers. Conclusions of the group on strengths and weaknesses of available evidence as well as consensus statements and directions for further research are provided in this study.The following papers were subject to group discussions and formed the basis for the consensus statements: Stähli A, Strauss FJ, Gruber R. () The use of platelet‐rich‐plasma to enhance the outcomes of implant‐related therapies: a systematic review Strauss FJ, Stähli A, Gruber R. (2018) The use of platelet‐rich‐fibrin to enhance the outcomes of implant‐related therapies: a systematic review Mombelli A, Hashim D, Cionca N. () What is the impact of titanium particles and bio‐corrosion on implant survival and complications? A critical review Stavropoulos A, Bertl K, Pietschmann P, Pandis N, Morten Schiødt, Klinge B. () The effect of antiresorptive drugs on implant therapy: a systematic review.
- 10 October 2018
- Published by Wiley in Clinical Oral Implants Research
- Vol. 29 (S18) , 93-99
Open AccessDrugs and diseases: Summary and consensus statements of group 1. The 5thEAO Consensus Conference 2018
Objectives: The task of this working group was to update the knowledge about the use of drugs and biologicals affecting healing of soft tissue and bone during implant treatment or procedures associated with it. Moreover, the impact of titanium particles and biocorrosion on complications and implant survival has been analysed.Materials and Methods: The literature in the areas of interest (platelet concentrates, antiresorptive drugs as well as implant–host interaction) was screened using systematic reviews for the former two areas, whereas a narrative critical review was performed for the latter topic. Two manuscripts on platelet concentrates, one manuscript on antiresorptive drugs and one manuscript on the effects of biocorrosion, were presented for group analysis with subsequent discussion in the plenum and final consensus approval.Results: Results and conclusions of the individual reviews of the three topics are presented in the respective papers. Conclusions of the group on strengths and weaknesses of available evidence as well as consensus statements and directions for further research are provided in this study.The following papers were subject to group discussions and formed the basis for the consensus statements: Stähli A, Strauss FJ, Gruber R. () The use of platelet‐rich‐plasma to enhance the outcomes of implant‐related therapies: a systematic review Strauss FJ, Stähli A, Gruber R. (2018) The use of platelet‐rich‐fibrin to enhance the outcomes of implant‐related therapies: a systematic review Mombelli A, Hashim D, Cionca N. () What is the impact of titanium particles and bio‐corrosion on implant survival and complications? A critical review Stavropoulos A, Bertl K, Pietschmann P, Pandis N, Morten Schiødt, Klinge B. () The effect of antiresorptive drugs on implant therapy: a systematic review.
- 8 October 2018
- Published by Wiley in Clinical Oral Implants Research
- Vol. 29, 58
Predictions of implant dentistry in Europe for 2030. A delphi study
- 8 October 2018
- Published by Wiley in Clinical Oral Implants Research
- Vol. 29, 58
Predictions of implant dentistry in Europe for 2030. A delphi study
- 17 April 2018
- Published by Wiley in Clinical Oral Implants Research
- Vol. 29 (6) , 557-567
A retrospective study on the crestal bone loss associated with different implant surfaces in chronic periodontitis patients under maintenance
Objective: To analyze retrospectively interproximal crestal bone loss (CBL) on external‐hex “non‐identical” (NI) dental implants with different surface topography, when placed in the same intra‐oral location in patients with a history of chronic periodontitis following maintenance care.Material and methods: The patient population consisted of 206 consecutive patients with a history of chronic periodontitis who underwent implant surgery between 2007 and 2010; 755 NI implants with different implant surfaces were placed at posterior mandibular sites: 72 machined, 145 acid‐etched/machined (hybrid), and 538 anodized. Crestal bone loss measurements were carried out analyzing the calibrated digital X‐rays taken at 1‐year intervals as part of the maintenance program, being the time of this retrospective examination from 1 to 3 years.Results: At 3 years (51 patients), the mean CBL was 1.36/1.35 mm at implant/patient level (range: 0–6 mm). A higher CBL was observed at anodized surface implants, when compared to machined and hybrid implants, being the mean CBL 1.48, 0.96, and 0.77 mm, respectively (p = .005). CBL between 2 and 3.9 mm was found in 10.6% of the implants at 3 years (95% CI: 6%–15%), ≥4 mm in 5% (95% CI: 2%–8%). Anodized surface implants had CBL >2 mm at 2 years of 9% (95% CI: 6%–12%) and at 3 years of 18% (95% CI: 12%–24%), which were 2.5 times higher than hybrid implants with 3.6% (95% CI: 0.8%–4%) and 7.4% (95% CI: 0%–17%), respectively.Conclusions: A higher CBL was observed in the anodized surface implants group, when compared to the hybrid implants group in patients with a history of chronic periodontitis followed during 1–3 years.
- 17 April 2018
- Published by Wiley in Clinical Oral Implants Research
- Vol. 29 (6) , 557-567
A retrospective study on the crestal bone loss associated with different implant surfaces in chronic periodontitis patients under maintenance
Objective: To analyze retrospectively interproximal crestal bone loss (CBL) on external‐hex “non‐identical” (NI) dental implants with different surface topography, when placed in the same intra‐oral location in patients with a history of chronic periodontitis following maintenance care.Material and methods: The patient population consisted of 206 consecutive patients with a history of chronic periodontitis who underwent implant surgery between 2007 and 2010; 755 NI implants with different implant surfaces were placed at posterior mandibular sites: 72 machined, 145 acid‐etched/machined (hybrid), and 538 anodized. Crestal bone loss measurements were carried out analyzing the calibrated digital X‐rays taken at 1‐year intervals as part of the maintenance program, being the time of this retrospective examination from 1 to 3 years.Results: At 3 years (51 patients), the mean CBL was 1.36/1.35 mm at implant/patient level (range: 0–6 mm). A higher CBL was observed at anodized surface implants, when compared to machined and hybrid implants, being the mean CBL 1.48, 0.96, and 0.77 mm, respectively (p = .005). CBL between 2 and 3.9 mm was found in 10.6% of the implants at 3 years (95% CI: 6%–15%), ≥4 mm in 5% (95% CI: 2%–8%). Anodized surface implants had CBL >2 mm at 2 years of 9% (95% CI: 6%–12%) and at 3 years of 18% (95% CI: 12%–24%), which were 2.5 times higher than hybrid implants with 3.6% (95% CI: 0.8%–4%) and 7.4% (95% CI: 0%–17%), respectively.Conclusions: A higher CBL was observed in the anodized surface implants group, when compared to the hybrid implants group in patients with a history of chronic periodontitis followed during 1–3 years.
- 9 September 2015
- Published by Wiley in Clinical Oral Implants Research
- Vol. 26 (S11) , 148-152
Long‐term stability of peri‐implant tissues after bone or soft tissue augmentation. Effect of zirconia or titanium abutments on peri‐implant soft tissues. Summary and consensus statements. The 4th EAO Consensus Conference 2015
Introduction: Several surgical techniques and prosthetic devices have been developed in the last decades, aiming to improve aesthetic, hygienic and functional outcomes that may affect the peri‐implant tissues, such as procedures of bone and soft tissue augmentation and the use of custom‐made abutments of titanium and zirconium.Materials and methods: Three systematic reviews, based on randomized clinical trials and prospective studies covering the above reported topics were analysed, and the detected evidence was exposed to interactive experts’ discussion during the group's and general assembly's meetings of the 4th EAO Consensus Conference. The results are reported using the following abbreviations: S‐T: short‐term evidence, M‐T: medium‐term evidence; L‐T: long‐term evidence; LE: limited evidence.Results: Soft tissue augmentation procedures may be indicated for the increase of soft tissue thickness and keratinized tissue, the reduction of interproximal peri‐implant bone loss, and the coverage of shallow peri‐implant soft tissue recessions (S‐T, LE), L‐T is lacking. Guided bone regeneration approaches (GBR) showed efficacy when used for ridge reconstruction after the complete healing of the soft tissues (S‐T & L‐T), and the stability of the augmented bone may play a role in the maintenance of the soft tissue position and dimensions (LE). No significant differences were observed between titanium and zirconia abutments when evaluating probing pocket depth, bleeding on probing, marginal bone levels and mucosal recessions. Zirconia abutments were associated with more biological complications but demonstrated superiority in terms of achieving natural soft tissue colour (S‐T).
- 9 September 2015
- Published by Wiley in Clinical Oral Implants Research
- Vol. 26 (S11) , 148-152
Long‐term stability of peri‐implant tissues after bone or soft tissue augmentation. Effect of zirconia or titanium abutments on peri‐implant soft tissues. Summary and consensus statements. The 4th EAO Consensus Conference 2015
Introduction: Several surgical techniques and prosthetic devices have been developed in the last decades, aiming to improve aesthetic, hygienic and functional outcomes that may affect the peri‐implant tissues, such as procedures of bone and soft tissue augmentation and the use of custom‐made abutments of titanium and zirconium.Materials and methods: Three systematic reviews, based on randomized clinical trials and prospective studies covering the above reported topics were analysed, and the detected evidence was exposed to interactive experts’ discussion during the group's and general assembly's meetings of the 4th EAO Consensus Conference. The results are reported using the following abbreviations: S‐T: short‐term evidence, M‐T: medium‐term evidence; L‐T: long‐term evidence; LE: limited evidence.Results: Soft tissue augmentation procedures may be indicated for the increase of soft tissue thickness and keratinized tissue, the reduction of interproximal peri‐implant bone loss, and the coverage of shallow peri‐implant soft tissue recessions (S‐T, LE), L‐T is lacking. Guided bone regeneration approaches (GBR) showed efficacy when used for ridge reconstruction after the complete healing of the soft tissues (S‐T & L‐T), and the stability of the augmented bone may play a role in the maintenance of the soft tissue position and dimensions (LE). No significant differences were observed between titanium and zirconia abutments when evaluating probing pocket depth, bleeding on probing, marginal bone levels and mucosal recessions. Zirconia abutments were associated with more biological complications but demonstrated superiority in terms of achieving natural soft tissue colour (S‐T).