Self-Identification of the Joint Centre of a Cable-Driven Shoulder Rehabilitator
- 1 April 2007
- conference paper
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10504729,p. 3767-3772
Abstract
This paper presents the joint centre self-identification of a novel cable-driven anthropocentric shoulder rehabilitator. For such a wearable rehabilitator, identification of joint centre is critical for kinematic modeling, path planning and motion control. However, the shoulder joint centre location is unknown when a user wears this rehabilitator and it differs among users. These complicate the initial patient preparatory. A joint centre self-identification model is formulated based on the differential change in the cable end-point distance. A computationally effective algorithm is employed to identify the shoulder joint centre. It does not require any external measurement devices because of the redundant actuation scheme in the cable-driven shoulder rehabilitator. In order to verify the effectiveness and robustness of the proposed algorithm, we conducted computer simulation studies. In the simulation example, although large errors (up to plusmn50mm) had been injected into the initial estimates, the joint centre was always accurately identified within four to five iterations.Keywords
This publication has 11 references indexed in Scilit:
- The evolution of methods for the capture of human movement leading to markerless motion capture for biomechanical applicationsJournal of NeuroEngineering and Rehabilitation, 2006
- Optimal Design of a Bio‐Inspired Anthropocentric Shoulder RehabilitatorApplied Bionics and Biomechanics, 2006
- A haptic device wearable on a human arm2005
- Efficient formulation approach for the forward kinematics of the 3-6 Stewart-Gough Platform2002
- Self-calibration of three-legged modular reconfigurable parallel robots based on leg-end distance errorsRobotica, 2001
- The position of the rotation center of the glenohumeral jointJournal of Biomechanics, 2000
- Movement biomechanics goes upwards: from the leg to the armJournal of Biomechanics, 2000
- Quantification of force abnormalities during passive and active-assisted upper-limb reaching movements in post-stroke hemiparesisIEEE Transactions on Biomedical Engineering, 1999
- Robot-aided neurorehabilitationIEEE Transactions on Rehabilitation Engineering, 1998
- An absolute stability criterion for the Lur'e problem with sector and slope restricted nonlinearitiesIEEE Transactions on Circuits and Systems I: Regular Papers, 1998