Efficacy of Periapical Radiography and Three Cone-Beam Computed Tomography Systems for Detection of Peri-Implant Dehiscence Defects: An in- Vitro Study
Authors:
Open Access
- 1 December 2020
- journal article
- research article
- Published by Salvia Medical Sciences Ltd in Journal of Biomedical Physics and Engineering
- Vol. 10 (6) , 751-760
Abstract
Background: Early detection of peri-implant bone defects is highly important because these defects eventually lead to gingival recession, bone loss and implant failure. Objective: This study aimed to assess and compare the efficacy of periapical radiography and three CBCT systems for the detection of peri-implant dehiscence defects.Material and Methods: In this vitro study, 124 titanium implants were placed in bovine ribs. The bone pieces were then mounted in boxes in the form of mandible and red dental wax was used to simulate the soft tissue. Crestal bone defects with 2, 3, and 4 mm depth were created in the ribs using a round bur. Periapical and CBCT images were then obtained. Images were investigated by two oral and maxillofacial radiologists twice with a two-week interval. The results were analyzed using chi-square, Kappa coefficient, Cochrane’s Q and McNemar tests as well as the receiver operating characteristic (ROC) curve. Results: The two observers showed good agreement in detection of sound and defective samples on periapical radiographs and CBCT scans. The level of agreement was low in detection of two samples with 2 mm defects on CBCT scans taken with Planmeca and NewTom 3G systems at the time of second assessment. NewTom 3G had the highest sensitivity (68.9%, 74.2% and 86.3%, respectively) and specificity (100% for all three) compared to other systems for detection of 2, 3 and 4 mm crestal bone defects. Conclusion: The inter-observer agreement increased with increase in depth of defects. NewTom 3G had the highest accuracy for detection of crestal bone defects.Keywords
This publication has 21 references indexed in Scilit:
- Diagnostic Accuracy of Three Cone Beam Computed Tomography Systems and Periapical Radiography for Detection of Fenestration Around Dental ImplantsContemporary Clinical Dentistry, 2018
- Impact of removable dentures on oral health-related quality of life among elderly adults in TaiwanBMC Oral Health, 2015
- Clinical and Radiological Classification of the Jawbone Anatomy in Endosseous Dental Implant TreatmentJournal of Oral and Maxillofacial Research, 2013
- Detection of periimplant fenestration and dehiscence with the use of two scan modes and the smallest voxel sizes of a cone-beam computed tomography deviceOral Surgery, Oral Medicine, Oral Pathology and Oral Radiology, 2013
- A Comparison of Peripheral Marginal Bone Loss at Dental Implants Measured With Conventional Intraoral Film and Digitized RadiographsJournal of Oral Implantology, 2012
- Outcomes assessment of patients treated with osseointegrated dental implants at the University of Washington Graduate Prosthodontic Program, 1988 to 2000.2009
- Consequences of Implant DesignDental Clinics of North America, 2006
- Influence of the Size of the Microgap on Crestal Bone Levels in Non‐Submerged Dental Implants: A Radiographic Study in the Canine MandibleJournal of Periodontology, 2002
- Stability of Implants and Natural Teeth as Determined by the Periotest Over 60 Months of FunctionJournal of Oral Implantology, 2001
- Criteria for success of osseointegrated endosseous implantsThe Journal of Prosthetic Dentistry, 1989