Amir Eskandarloo
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Amir Eskandarloo has a total of 64 co-authors. Here are the top co-authors by number of shared publications:
Abbas Shokri
Department of Oral and Maxillofacial Radiology, Dental Research Center, Dental School, Hamadan University of Medical Sciences, Hamadan, Iran
5 shared publicationsJalal Poorolajal
Department of Epidemiology School of Public Health Hamadan University of Medical Sciences Hamadan Iran
5 shared publications- Abbas Shokri
Department of Oral and Maxillofacial Radiology, Dental School, Hamadan University of Medical Sciences, Hamadan, Iran
4 shared publications - Faezeh Yousefi
Department of Oral and Maxillofacial Radiology, Hamadan University of Medical Sciences, Hamadan, Iran
2 shared publications - Hamed Karkehabadi
Department of Endodontics, Faculty of Dentistry, Dental Research Center, Hamadan University of Medical Sciences, Hamadan, Iran
2 shared publications - Karim Ghazikhanlou Sani
Department of Radiology, School of Allied Medical Sciences, Hamadan University of Medical Sciences, Hamadan, Iran
2 shared publications
Latest Publications
- 21 October 2022
- Published by Wiley in Australian Endodontic Journal
- Vol. 49 (S1) , 132-145
Effect of different intracanal posts and exposure parameters on detection of vertical root fractures by cone‐beam computed tomography
This study evaluated the effect of different amperage values and voxel sizes of two CBCT scanners on VRF detection in the presence of different intracanal posts. After post‐space preparation, VRFs were induced in half of the samples of 20 maxillary premolars. Five different intracanal posts were passively placed in each root canal. Samples were scanned using CS 9300 and Cranex3D with two different voxel sizes and amperage setting in each unit. The diagnostic sensitivity, specificity and accuracy were compared using the Mann–Whitney and Kruskal‐Wallis tests (α = 0.05). Changes in amperage and voxel size did not affect the detection of VRFs (p ⟩ 0.05). The VRF detection accuracy was the highest in fibreglass and the lowest in nickel‐chromium group. Changes in amperage and voxel size within assessed values do not seem to influence the detection of VRF whereas different intracanal post‐materials have significant effect on VRF detection.
- 21 October 2022
- Published by Wiley in Australian Endodontic Journal
- Vol. 49 (S1) , 132-145
Effect of different intracanal posts and exposure parameters on detection of vertical root fractures by cone‐beam computed tomography
This study evaluated the effect of different amperage values and voxel sizes of two CBCT scanners on VRF detection in the presence of different intracanal posts. After post‐space preparation, VRFs were induced in half of the samples of 20 maxillary premolars. Five different intracanal posts were passively placed in each root canal. Samples were scanned using CS 9300 and Cranex3D with two different voxel sizes and amperage setting in each unit. The diagnostic sensitivity, specificity and accuracy were compared using the Mann–Whitney and Kruskal‐Wallis tests (α = 0.05). Changes in amperage and voxel size did not affect the detection of VRFs (p ⟩ 0.05). The VRF detection accuracy was the highest in fibreglass and the lowest in nickel‐chromium group. Changes in amperage and voxel size within assessed values do not seem to influence the detection of VRF whereas different intracanal post‐materials have significant effect on VRF detection.
- Open Access
- 1 December 2020
- Published by Salvia Medical Sciences Ltd in Journal of Biomedical Physics and Engineering
- Vol. 10 (6) , 751-760
Efficacy of Periapical Radiography and Three Cone-Beam Computed Tomography Systems for Detection of Peri-Implant Dehiscence Defects: An in- Vitro Study
Background: Early detection of peri-implant bone defects is highly important because these defects eventually lead to gingival recession, bone loss and implant failure. Objective: This study aimed to assess and compare the efficacy of periapical radiography and three CBCT systems for the detection of peri-implant dehiscence defects.Material and Methods: In this vitro study, 124 titanium implants were placed in bovine ribs. The bone pieces were then mounted in boxes in the form of mandible and red dental wax was used to simulate the soft tissue. Crestal bone defects with 2, 3, and 4 mm depth were created in the ribs using a round bur. Periapical and CBCT images were then obtained. Images were investigated by two oral and maxillofacial radiologists twice with a two-week interval. The results were analyzed using chi-square, Kappa coefficient, Cochrane’s Q and McNemar tests as well as the receiver operating characteristic (ROC) curve. Results: The two observers showed good agreement in detection of sound and defective samples on periapical radiographs and CBCT scans. The level of agreement was low in detection of two samples with 2 mm defects on CBCT scans taken with Planmeca and NewTom 3G systems at the time of second assessment. NewTom 3G had the highest sensitivity (68.9%, 74.2% and 86.3%, respectively) and specificity (100% for all three) compared to other systems for detection of 2, 3 and 4 mm crestal bone defects. Conclusion: The inter-observer agreement increased with increase in depth of defects. NewTom 3G had the highest accuracy for detection of crestal bone defects.
- 1 December 2020
- Published by Salvia Medical Sciences Ltd in Journal of Biomedical Physics and Engineering
- Vol. 10 (6) , 751-760
Open AccessEfficacy of Periapical Radiography and Three Cone-Beam Computed Tomography Systems for Detection of Peri-Implant Dehiscence Defects: An in- Vitro Study
Background: Early detection of peri-implant bone defects is highly important because these defects eventually lead to gingival recession, bone loss and implant failure. Objective: This study aimed to assess and compare the efficacy of periapical radiography and three CBCT systems for the detection of peri-implant dehiscence defects.Material and Methods: In this vitro study, 124 titanium implants were placed in bovine ribs. The bone pieces were then mounted in boxes in the form of mandible and red dental wax was used to simulate the soft tissue. Crestal bone defects with 2, 3, and 4 mm depth were created in the ribs using a round bur. Periapical and CBCT images were then obtained. Images were investigated by two oral and maxillofacial radiologists twice with a two-week interval. The results were analyzed using chi-square, Kappa coefficient, Cochrane’s Q and McNemar tests as well as the receiver operating characteristic (ROC) curve. Results: The two observers showed good agreement in detection of sound and defective samples on periapical radiographs and CBCT scans. The level of agreement was low in detection of two samples with 2 mm defects on CBCT scans taken with Planmeca and NewTom 3G systems at the time of second assessment. NewTom 3G had the highest sensitivity (68.9%, 74.2% and 86.3%, respectively) and specificity (100% for all three) compared to other systems for detection of 2, 3 and 4 mm crestal bone defects. Conclusion: The inter-observer agreement increased with increase in depth of defects. NewTom 3G had the highest accuracy for detection of crestal bone defects.
- Open Access
- 22 April 2020
- Published by Bentham Science Publishers Ltd. in The Open Dentistry Journal
- Vol. 14 (1) , 178-183
Is Ultrasonography Efficient for the Detection of the Zygomatic Arch, Nasal Bone and Cartilage Fractures?
Is Ultrasonography Efficient for the Detection of the Zygomatic Arch, Nasal Bone and Cartilage Fractures?
- 22 April 2020
- Published by Bentham Science Publishers Ltd. in The Open Dentistry Journal
- Vol. 14 (1) , 178-183
Open AccessIs Ultrasonography Efficient for the Detection of the Zygomatic Arch, Nasal Bone and Cartilage Fractures?
Is Ultrasonography Efficient for the Detection of the Zygomatic Arch, Nasal Bone and Cartilage Fractures?
- Open Access
- 30 December 2019
- Published by Maad Rayan Publishing Company in Avicenna Journal of Dental Research
- Vol. 11 (4) , 139-143
The Ability of Different Observers in Measuring Dimensions of Objects and Cavities in Cone Beam-CT Images
Background: Accuracy of measurements obtained from cone-beam computed tomography (CBCT) images, which is a diagnostic tool in dentistry, is an important issue. The aim of this study was to compare the ability of different operators in measuring dimensions using CBCT software. Methods: In this experimental study, 35 different areas using opaque objects and drilling cavities were prepared on 3 phantoms which were made from fresh beef ribs. Then each phantom was scanned by CBCT Promax 3D. The mentioned areas were measured on CBCT images 2 times with one week interval by four observer groups consisting two radiologists, two periodontists, two maxillofacial surgeons, and two general dentists. Obtained measurements from each group of observers were compared with those of other groups and also with measurements of a digital caliper as a gold standard by intra-class correlation coefficient (ICC). Then the measured dimensions, with respect to their application, were divided into three clusters including cluster 1: 2-7 mm, cluster 2: 7-16 mm, and cluster 3: more than 16 mm. T test was used to compare the mean value of each cluster with the mean value of the gold standard. Results: In general, based on ICC, inter- and intra-observer agreement, agreement between observer groups, and agreement between each group and the gold standard were significant. The results of t test showed a significant difference between the mean value of data and that of gold standard in clusters 1 and 3. Conclusions: Generally, high accuracy and reliability were reported for different specialists of dentistry and general dentists in measuring the dimensions of objects and cavities in CBCT images.
- 30 December 2019
- Published by Maad Rayan Publishing Company in Avicenna Journal of Dental Research
- Vol. 11 (4) , 139-143
Open AccessThe Ability of Different Observers in Measuring Dimensions of Objects and Cavities in Cone Beam-CT Images
Background: Accuracy of measurements obtained from cone-beam computed tomography (CBCT) images, which is a diagnostic tool in dentistry, is an important issue. The aim of this study was to compare the ability of different operators in measuring dimensions using CBCT software. Methods: In this experimental study, 35 different areas using opaque objects and drilling cavities were prepared on 3 phantoms which were made from fresh beef ribs. Then each phantom was scanned by CBCT Promax 3D. The mentioned areas were measured on CBCT images 2 times with one week interval by four observer groups consisting two radiologists, two periodontists, two maxillofacial surgeons, and two general dentists. Obtained measurements from each group of observers were compared with those of other groups and also with measurements of a digital caliper as a gold standard by intra-class correlation coefficient (ICC). Then the measured dimensions, with respect to their application, were divided into three clusters including cluster 1: 2-7 mm, cluster 2: 7-16 mm, and cluster 3: more than 16 mm. T test was used to compare the mean value of each cluster with the mean value of the gold standard. Results: In general, based on ICC, inter- and intra-observer agreement, agreement between observer groups, and agreement between each group and the gold standard were significant. The results of t test showed a significant difference between the mean value of data and that of gold standard in clusters 1 and 3. Conclusions: Generally, high accuracy and reliability were reported for different specialists of dentistry and general dentists in measuring the dimensions of objects and cavities in CBCT images.
- Open Access
- 30 December 2019
- Published by Wroclaw Medical University in Dental and Medical Problems
- Vol. 56 (4) , 357-363
Evaluation of the efficacy of the metal artifact reduction algorithm in the detection of a vertical root fracture in endodontically treated teeth in cone-beam computed tomography images: An in vitro study
Three-dimensional (3D) cone-beam computed tomography (CBCT) scans play an important role in dental diagnostics and treatment planning, especially in detecting vertical root fractures (VRFs). However, artifacts caused by high-density dental materials can negatively affect the quality of CBCT images by decreasing contrast and masking structures. The aim of this study was to assess the efficacy of artifact removal software in detecting VRFs in endodontically treated teeth on CBCT scans. This study evaluated 70 endodontically treated single-rooted teeth. Half of the teeth were cracked by introducing a wedge into the canal and tapping gently with a hammer; the rest remained untouched as a control group. The teeth were then mounted in a bovine rib bone. Soft tissue was simulated using red dental wax. Cone-beam computed tomography scans were taken using the NewTom® 3G, ProMax® 3D and Cranex® 3D CBCT systems, and the MATLAB software was applied. The images were evaluated by 2 oral and maxillofacial radiologists, and the results were recorded in a checklist. The data was analyzed using the κ coefficient, McNemar's test and the receiver operating characteristic (ROC) curves. A significant inter-observer agreement was noted between the 2 observers in detecting VRFs using all CBCT systems. In all systems, the use of the MATLAB software improved the detection of VRFs, but the difference was not significant in the NewTom 3G (p = 0.119) and ProMax 3D (p = 0.455) systems. However, the difference was significant in the Cranex 3D system (p = 0.039). The MATLAB artifact removal software can enhance the detection of VRFs on CBCT scans to some extent.
- 30 December 2019
- Published by Wroclaw Medical University in Dental and Medical Problems
- Vol. 56 (4) , 357-363
Open AccessEvaluation of the efficacy of the metal artifact reduction algorithm in the detection of a vertical root fracture in endodontically treated teeth in cone-beam computed tomography images: An in vitro study
Three-dimensional (3D) cone-beam computed tomography (CBCT) scans play an important role in dental diagnostics and treatment planning, especially in detecting vertical root fractures (VRFs). However, artifacts caused by high-density dental materials can negatively affect the quality of CBCT images by decreasing contrast and masking structures. The aim of this study was to assess the efficacy of artifact removal software in detecting VRFs in endodontically treated teeth on CBCT scans. This study evaluated 70 endodontically treated single-rooted teeth. Half of the teeth were cracked by introducing a wedge into the canal and tapping gently with a hammer; the rest remained untouched as a control group. The teeth were then mounted in a bovine rib bone. Soft tissue was simulated using red dental wax. Cone-beam computed tomography scans were taken using the NewTom® 3G, ProMax® 3D and Cranex® 3D CBCT systems, and the MATLAB software was applied. The images were evaluated by 2 oral and maxillofacial radiologists, and the results were recorded in a checklist. The data was analyzed using the κ coefficient, McNemar's test and the receiver operating characteristic (ROC) curves. A significant inter-observer agreement was noted between the 2 observers in detecting VRFs using all CBCT systems. In all systems, the use of the MATLAB software improved the detection of VRFs, but the difference was not significant in the NewTom 3G (p = 0.119) and ProMax 3D (p = 0.455) systems. However, the difference was significant in the Cranex 3D system (p = 0.039). The MATLAB artifact removal software can enhance the detection of VRFs on CBCT scans to some extent.
- Open Access
- 1 January 2019
- Published by Medknow in Contemporary Clinical Dentistry
- Vol. 10 (1) , 36-41
Association between marginal bone loss and bone quality at dental implant sites based on evidence from cone beam computed tomography and periapical radiographs
Objective: The aim of this study was to assess bone quality in patient's preoperative cone beam computed tomography (CBCT) and their relation with marginal bone loss at implant placement sites over follow-up periods. Materials and Methods: In this retrospective cross-sectional study, 100 implants were evaluated. The implants had been placed in the maxillary and mandibular edentulous areas. Bone quality at implant placement sites was measured on preoperative CBCTs and then classified by two observers according to Lekholm and Zarb classification. Marginal bone height was then measured on periapical radiographs obtained at baseline and then 6, 12, 18, 24, and 30 months' follow-up periods from a reference point (implant shoulder) to the bone-implant interface. The relation between bone quality and bone loss was assessed. ANOVA was used to compare mean difference among groups and Pearson correlation coefficient to assess the correlation between observers. All statistical analyses were performed at 0.05 significance level using Stata 11 software (StataCorp, College Station, TX, USA). Results: Of 100 implants, 48 were placed in the maxilla and 52 in the mandible. There was no significant difference between bone quality and the mean bone loss at follow-up periods. Using Pearson's correlation coefficient, it was shown that with an increase in bone quality, marginal bone loss was decreased at follow-up periods. Conclusions: The results confirmed that during the follow-up periods, less bone loss was observed in implant areas with higher bone quality and CBCT is a reliable tool for assessing bone quality at implant placement sites and estimation of subsequent treatment prognosis.
- 1 January 2019
- Published by Medknow in Contemporary Clinical Dentistry
- Vol. 10 (1) , 36-41
Open AccessAssociation between marginal bone loss and bone quality at dental implant sites based on evidence from cone beam computed tomography and periapical radiographs
Objective: The aim of this study was to assess bone quality in patient's preoperative cone beam computed tomography (CBCT) and their relation with marginal bone loss at implant placement sites over follow-up periods. Materials and Methods: In this retrospective cross-sectional study, 100 implants were evaluated. The implants had been placed in the maxillary and mandibular edentulous areas. Bone quality at implant placement sites was measured on preoperative CBCTs and then classified by two observers according to Lekholm and Zarb classification. Marginal bone height was then measured on periapical radiographs obtained at baseline and then 6, 12, 18, 24, and 30 months' follow-up periods from a reference point (implant shoulder) to the bone-implant interface. The relation between bone quality and bone loss was assessed. ANOVA was used to compare mean difference among groups and Pearson correlation coefficient to assess the correlation between observers. All statistical analyses were performed at 0.05 significance level using Stata 11 software (StataCorp, College Station, TX, USA). Results: Of 100 implants, 48 were placed in the maxilla and 52 in the mandible. There was no significant difference between bone quality and the mean bone loss at follow-up periods. Using Pearson's correlation coefficient, it was shown that with an increase in bone quality, marginal bone loss was decreased at follow-up periods. Conclusions: The results confirmed that during the follow-up periods, less bone loss was observed in implant areas with higher bone quality and CBCT is a reliable tool for assessing bone quality at implant placement sites and estimation of subsequent treatment prognosis.
- Open Access
- 31 August 2018
- Published by Bentham Science Publishers Ltd. in The Open Dentistry Journal
- Vol. 12 (1) , 586-595
Performance of Cone Beam Computed Tomography Systems in Visualizing the Cortical Plate in 3D Image Reconstruction: An In Vitro Study
Introduction: Cortical bone is an important anatomical structure and its thickness needs to be determined prior to many dental procedures to ensure treatment success. Imaging modalities are necessarily used in dentistry for treatment planning and dental procedures. Three-dimensional image reconstruction not only provides visual information but also enables accurate measurement of anatomical structures; thus, it is necessarily required for maxillofacial examination and in case of skeletal problems in this region. Aims: This study aimed to assess the ability of three Cone Beam Computed Tomography (CBCT) systems including Cranex 3D, NewTom 3G and 3D Promax for Three-Dimensional (3D) image reconstruction of the cortical plate with variable thicknesses. Methods: Depending on the cortical bone thickness, samples were evaluated in three groups of ≤ 0. 5 mm, 0.6 -1 mm and 1.1-1.5 mm cortical bone thickness. The CBCT scans were obtained from each sample using three systems, their respective FOVs, and 3D scans were reconstructed using their software programs. Two observers viewed the images twice with a two-week interval. The ability of each system in the 3D reconstruction of different thicknesses of cortical bone was determined based on its visualization on the scans. The data were analyzed using SPSS and Kappa test. Results: The three systems showed the greatest difference in the 3D reconstruction of cortical bone with < 0.5 mm thickness. Cranex 3D with 4×6 cm2 FOV had the highest and 3D Promax with 8×8 cm2 FOV had the lowest efficacy for 3D reconstruction of cortical bone. Cranex 3D with 4×6 cm2 and 6×8 cm2 FOVs and NewTom 3G with 5×5 cm2 and 8×5 cm2 FOVs showed significantly higher efficacy for 3D reconstruction of cortical bone with 0.6-1mm thickness while 3D Promax followed by NewTom 3G with 8×8 cm2 FOV had the lowest efficacy for this purpose. Conclusion: Most CBCT systems have high efficacy for 3D image reconstruction of cortical bone with thicknesses over 1 mm while they have poor efficacy for image reconstruction of cortical bone with less than 0.5 mm thickness. Thus, for accurate visualization of anatomical structures on CBCT scans, systems with smaller FOVs and consequently smaller voxel size are preferred.
- 31 August 2018
- Published by Bentham Science Publishers Ltd. in The Open Dentistry Journal
- Vol. 12 (1) , 586-595
Open AccessPerformance of Cone Beam Computed Tomography Systems in Visualizing the Cortical Plate in 3D Image Reconstruction: An In Vitro Study
Introduction: Cortical bone is an important anatomical structure and its thickness needs to be determined prior to many dental procedures to ensure treatment success. Imaging modalities are necessarily used in dentistry for treatment planning and dental procedures. Three-dimensional image reconstruction not only provides visual information but also enables accurate measurement of anatomical structures; thus, it is necessarily required for maxillofacial examination and in case of skeletal problems in this region. Aims: This study aimed to assess the ability of three Cone Beam Computed Tomography (CBCT) systems including Cranex 3D, NewTom 3G and 3D Promax for Three-Dimensional (3D) image reconstruction of the cortical plate with variable thicknesses. Methods: Depending on the cortical bone thickness, samples were evaluated in three groups of ≤ 0. 5 mm, 0.6 -1 mm and 1.1-1.5 mm cortical bone thickness. The CBCT scans were obtained from each sample using three systems, their respective FOVs, and 3D scans were reconstructed using their software programs. Two observers viewed the images twice with a two-week interval. The ability of each system in the 3D reconstruction of different thicknesses of cortical bone was determined based on its visualization on the scans. The data were analyzed using SPSS and Kappa test. Results: The three systems showed the greatest difference in the 3D reconstruction of cortical bone with < 0.5 mm thickness. Cranex 3D with 4×6 cm2 FOV had the highest and 3D Promax with 8×8 cm2 FOV had the lowest efficacy for 3D reconstruction of cortical bone. Cranex 3D with 4×6 cm2 and 6×8 cm2 FOVs and NewTom 3G with 5×5 cm2 and 8×5 cm2 FOVs showed significantly higher efficacy for 3D reconstruction of cortical bone with 0.6-1mm thickness while 3D Promax followed by NewTom 3G with 8×8 cm2 FOV had the lowest efficacy for this purpose. Conclusion: Most CBCT systems have high efficacy for 3D image reconstruction of cortical bone with thicknesses over 1 mm while they have poor efficacy for image reconstruction of cortical bone with less than 0.5 mm thickness. Thus, for accurate visualization of anatomical structures on CBCT scans, systems with smaller FOVs and consequently smaller voxel size are preferred.
- Open Access
- 1 July 2018
- Published by Wolters Kluwer Health in Contemporary Clinical Dentistry
- Vol. 9 (3) , 376-381
Diagnostic Accuracy of Three Cone Beam Computed Tomography Systems and Periapical Radiography for Detection of Fenestration Around Dental Implants
Context: Early detection of peri-implant bone defects is highly important to prevent further bone loss and implant failure. Aims: This study aimed to assess the diagnostic accuracy of three cone-beam computed tomography (CBCT) systems and periapical radiography for detection of fenestration around dental implants. Methods: Thirty-one titanium implants were placed in the bovine ribs, in which peri-implant fenestration were simulated. Using a round fissure bur, fenestration defects were created in the apical-third region of implants. CBCT and PA radiographs were obtained before and after creating the defects. The results were analyzed using Chi-square test; kappa coefficient; Cochran's Q-test; McNemar's test; and sensitivity, specificity, positive predictive value, and negative predictive value; and receiver operating characteristic curve. Results: A significant agreement was noted between the two observers in the detection of defect-free samples in all imaging systems (P < 0.05). In detection of samples with defects, a significant agreement was observed between the two observers in use of Cranex three-dimensional and NewTom 3G systems (P < 0.05), but the agreement was not significant for detection of defects in use of Promax 3D (P > 0.05). The results showed no significant difference among the four imaging systems in detection of defect-free samples while the difference was significant among the four groups for detection of defects (P < 0.05). NewTom had the highest sensitivity (75.81%) and specificity (100%) for detection of fenestration. Conclusions: Within the limitations of CBCT systems different kVp used by different systems, artifacts and noises that influences image quality, difference in diagnostic value of different CBCT systems is due to the differences in type of detector and voxel size. In terms of the type of detector, our results showed that NewTom 3G, which has a higher (kVP) than other systems and the highest accuracy for detection of fenestration.
- 1 July 2018
- Published by Wolters Kluwer Health in Contemporary Clinical Dentistry
- Vol. 9 (3) , 376-381
Open AccessDiagnostic Accuracy of Three Cone Beam Computed Tomography Systems and Periapical Radiography for Detection of Fenestration Around Dental Implants
Context: Early detection of peri-implant bone defects is highly important to prevent further bone loss and implant failure. Aims: This study aimed to assess the diagnostic accuracy of three cone-beam computed tomography (CBCT) systems and periapical radiography for detection of fenestration around dental implants. Methods: Thirty-one titanium implants were placed in the bovine ribs, in which peri-implant fenestration were simulated. Using a round fissure bur, fenestration defects were created in the apical-third region of implants. CBCT and PA radiographs were obtained before and after creating the defects. The results were analyzed using Chi-square test; kappa coefficient; Cochran's Q-test; McNemar's test; and sensitivity, specificity, positive predictive value, and negative predictive value; and receiver operating characteristic curve. Results: A significant agreement was noted between the two observers in the detection of defect-free samples in all imaging systems (P < 0.05). In detection of samples with defects, a significant agreement was observed between the two observers in use of Cranex three-dimensional and NewTom 3G systems (P < 0.05), but the agreement was not significant for detection of defects in use of Promax 3D (P > 0.05). The results showed no significant difference among the four imaging systems in detection of defect-free samples while the difference was significant among the four groups for detection of defects (P < 0.05). NewTom had the highest sensitivity (75.81%) and specificity (100%) for detection of fenestration. Conclusions: Within the limitations of CBCT systems different kVp used by different systems, artifacts and noises that influences image quality, difference in diagnostic value of different CBCT systems is due to the differences in type of detector and voxel size. In terms of the type of detector, our results showed that NewTom 3G, which has a higher (kVP) than other systems and the highest accuracy for detection of fenestration.
- Open Access
- 1 March 2018
- Published by CMV Verlag in Avicenna Journal of Clinical Medicine
- Vol. 24 (4) , 345-351
Comparison of Two Cone-Beam Computed Tomography Systems Regarding Linear Measurement Accuracy for Implant Sites in the Mandible: An In-Vitro Study
- 1 March 2018
- Published by CMV Verlag in Avicenna Journal of Clinical Medicine
- Vol. 24 (4) , 345-351
Open AccessComparison of Two Cone-Beam Computed Tomography Systems Regarding Linear Measurement Accuracy for Implant Sites in the Mandible: An In-Vitro Study
- Open Access
- 1 January 2018
- Published by Maad Rayan Publishing Company
- Vol. 13 (1) , 126-131
Iatrogenic Errors during Root Canal Instrumentation Performed by Dental Students
The present study was set to investigate the training quality and its association with the quality of root canal therapy performed by fifth year dentistry students. A total number of 432 records of endodontic treatment performed by fifth year dentistry students were qualified to be further investigated. Radiographs were assessed by two independent endodontists. Apical transportation, apical perforation, gouging, ledge formation, and the quality of temporary restoration were error types investigated in the present study. the prevalence of apical transportation, ledge formation, and apical perforation errors were significantly higher in molars in comparison with other types of teeth. The most prevalent type of error was the apical transportation, which was significantly higher in mandibular teeth. There was no significant differences among teeth in terms of other types of errors. The quality of training provided for dentistry students should be improved and endodontic curriculum should be modified.
- 1 January 2018
- Published by Maad Rayan Publishing Company
- Vol. 13 (1) , 126-131
Open AccessIatrogenic Errors during Root Canal Instrumentation Performed by Dental Students
The present study was set to investigate the training quality and its association with the quality of root canal therapy performed by fifth year dentistry students. A total number of 432 records of endodontic treatment performed by fifth year dentistry students were qualified to be further investigated. Radiographs were assessed by two independent endodontists. Apical transportation, apical perforation, gouging, ledge formation, and the quality of temporary restoration were error types investigated in the present study. the prevalence of apical transportation, ledge formation, and apical perforation errors were significantly higher in molars in comparison with other types of teeth. The most prevalent type of error was the apical transportation, which was significantly higher in mandibular teeth. There was no significant differences among teeth in terms of other types of errors. The quality of training provided for dentistry students should be improved and endodontic curriculum should be modified.