AEAmir Eskandarloo

Amir Eskandarloo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Amir Eskandarloo has a total of 64 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Effect of different intracanal posts and exposure parameters on detection of vertical root fractures by cone‐beam computed tomography

    by Abbas Shokri, Amir Eskandarloo, Foozie Zahedi, Hamed Karkehabadi, Maryam Foroozandeh, Maryam Farhadian

    This study evaluated the effect of different amperage values and voxel sizes of two CBCT scanners on VRF detection in the presence of different intracanal posts. After post‐space preparation, VRFs were induced in half of the samples of 20 maxillary premolars. Five different intracanal posts were passively placed in each root canal. Samples were scanned using CS 9300 and Cranex3D with two different voxel sizes and amperage setting in each unit. The diagnostic sensitivity, specificity and accuracy were compared using the Mann–Whitney and Kruskal‐Wallis tests (α = 0.05). Changes in amperage and voxel size did not affect the detection of VRFs (p ⟩ 0.05). The VRF detection accuracy was the highest in fibreglass and the lowest in nickel‐chromium group. Changes in amperage and voxel size within assessed values do not seem to influence the detection of VRF whereas different intracanal post‐materials have significant effect on VRF detection.


  • Open Access

    Efficacy of Periapical Radiography and Three Cone-Beam Computed Tomography Systems for Detection of Peri-Implant Dehiscence Defects: An in- Vitro Study

    by V Akheshteh, A Eskandarloo, S Saati, M R Jamalpour, N Mohammad Gholi Mezerji

    Background: Early detection of peri-implant bone defects is highly important because these defects eventually lead to gingival recession, bone loss and implant failure. Objective: This study aimed to assess and compare the efficacy of periapical radiography and three CBCT systems for the detection of peri-implant dehiscence defects.Material and Methods: In this vitro study, 124 titanium implants were placed in bovine ribs. The bone pieces were then mounted in boxes in the form of mandible and red dental wax was used to simulate the soft tissue. Crestal bone defects with 2, 3, and 4 mm depth were created in the ribs using a round bur. Periapical and CBCT images were then obtained. Images were investigated by two oral and maxillofacial radiologists twice with a two-week interval. The results were analyzed using chi-square, Kappa coefficient, Cochrane’s Q and McNemar tests as well as the receiver operating characteristic (ROC) curve. Results: The two observers showed good agreement in detection of sound and defective samples on periapical radiographs and CBCT scans. The level of agreement was low in detection of two samples with 2 mm defects on CBCT scans taken with Planmeca and NewTom 3G systems at the time of second assessment. NewTom 3G had the highest sensitivity (68.9%, 74.2% and 86.3%, respectively) and specificity (100% for all three) compared to other systems for detection of 2, 3 and 4 mm crestal bone defects. Conclusion: The inter-observer agreement increased with increase in depth of defects. NewTom 3G had the highest accuracy for detection of crestal bone defects.


  • Open Access

    Is Ultrasonography Efficient for the Detection of the Zygomatic Arch, Nasal Bone and Cartilage Fractures?

    by Amir Eskandarloo, Atena Karimi, Abbas Shokri, Jalal Poorolajal, Mohammad Hosseinipanah

    Is Ultrasonography Efficient for the Detection of the Zygomatic Arch, Nasal Bone and Cartilage Fractures?


  • Open Access

    The Ability of Different Observers in Measuring Dimensions of Objects and Cavities in Cone Beam-CT Images

    by Fatemeh Eskandarloo, Amir Eskandarloo, Payam Amini

    Background: Accuracy of measurements obtained from cone-beam computed tomography (CBCT) images, which is a diagnostic tool in dentistry, is an important issue. The aim of this study was to compare the ability of different operators in measuring dimensions using CBCT software. Methods: In this experimental study, 35 different areas using opaque objects and drilling cavities were prepared on 3 phantoms which were made from fresh beef ribs. Then each phantom was scanned by CBCT Promax 3D. The mentioned areas were measured on CBCT images 2 times with one week interval by four observer groups consisting two radiologists, two periodontists, two maxillofacial surgeons, and two general dentists. Obtained measurements from each group of observers were compared with those of other groups and also with measurements of a digital caliper as a gold standard by intra-class correlation coefficient (ICC). Then the measured dimensions, with respect to their application, were divided into three clusters including cluster 1: 2-7 mm, cluster 2: 7-16 mm, and cluster 3: more than 16 mm. T test was used to compare the mean value of each cluster with the mean value of the gold standard. Results: In general, based on ICC, inter- and intra-observer agreement, agreement between observer groups, and agreement between each group and the gold standard were significant. The results of t test showed a significant difference between the mean value of data and that of gold standard in clusters 1 and 3. Conclusions: Generally, high accuracy and reliability were reported for different specialists of dentistry and general dentists in measuring the dimensions of objects and cavities in CBCT images.


  • Open Access

    Evaluation of the efficacy of the metal artifact reduction algorithm in the detection of a vertical root fracture in endodontically treated teeth in cone-beam computed tomography images: An in vitro study

    by Samira Saati, Amir Eskandarloo, Alireza Falahi, Leili Tapak, Bahareh Hekmat

    Three-dimensional (3D) cone-beam computed tomography (CBCT) scans play an important role in dental diagnostics and treatment planning, especially in detecting vertical root fractures (VRFs). However, artifacts caused by high-density dental materials can negatively affect the quality of CBCT images by decreasing contrast and masking structures. The aim of this study was to assess the efficacy of artifact removal software in detecting VRFs in endodontically treated teeth on CBCT scans. This study evaluated 70 endodontically treated single-rooted teeth. Half of the teeth were cracked by introducing a wedge into the canal and tapping gently with a hammer; the rest remained untouched as a control group. The teeth were then mounted in a bovine rib bone. Soft tissue was simulated using red dental wax. Cone-beam computed tomography scans were taken using the NewTom® 3G, ProMax® 3D and Cranex® 3D CBCT systems, and the MATLAB software was applied. The images were evaluated by 2 oral and maxillofacial radiologists, and the results were recorded in a checklist. The data was analyzed using the κ coefficient, McNemar's test and the receiver operating characteristic (ROC) curves. A significant inter-observer agreement was noted between the 2 observers in detecting VRFs using all CBCT systems. In all systems, the use of the MATLAB software improved the detection of VRFs, but the difference was not significant in the NewTom 3G (p = 0.119) and ProMax 3D (p = 0.455) systems. However, the difference was significant in the Cranex 3D system (p = 0.039). The MATLAB artifact removal software can enhance the detection of VRFs on CBCT scans to some extent.


  • Open Access

    Association between marginal bone loss and bone quality at dental implant sites based on evidence from cone beam computed tomography and periapical radiographs

    by Faezeh Yousefi, Amir Eskandarloo, Reza Arabi, Mohsen Bidgoli, Jalal Poorolajal

    Objective: The aim of this study was to assess bone quality in patient's preoperative cone beam computed tomography (CBCT) and their relation with marginal bone loss at implant placement sites over follow-up periods. Materials and Methods: In this retrospective cross-sectional study, 100 implants were evaluated. The implants had been placed in the maxillary and mandibular edentulous areas. Bone quality at implant placement sites was measured on preoperative CBCTs and then classified by two observers according to Lekholm and Zarb classification. Marginal bone height was then measured on periapical radiographs obtained at baseline and then 6, 12, 18, 24, and 30 months' follow-up periods from a reference point (implant shoulder) to the bone-implant interface. The relation between bone quality and bone loss was assessed. ANOVA was used to compare mean difference among groups and Pearson correlation coefficient to assess the correlation between observers. All statistical analyses were performed at 0.05 significance level using Stata 11 software (StataCorp, College Station, TX, USA). Results: Of 100 implants, 48 were placed in the maxilla and 52 in the mandible. There was no significant difference between bone quality and the mean bone loss at follow-up periods. Using Pearson's correlation coefficient, it was shown that with an increase in bone quality, marginal bone loss was decreased at follow-up periods. Conclusions: The results confirmed that during the follow-up periods, less bone loss was observed in implant areas with higher bone quality and CBCT is a reliable tool for assessing bone quality at implant placement sites and estimation of subsequent treatment prognosis.


  • Open Access

    Performance of Cone Beam Computed Tomography Systems in Visualizing the Cortical Plate in 3D Image Reconstruction: An In Vitro Study

    by Abbas Shokri, Mohammad Reza Jamalpour, Amir Eskandarloo, Mostafa Godiny, Payam Amini, Atefeh Khavid

    Introduction: Cortical bone is an important anatomical structure and its thickness needs to be determined prior to many dental procedures to ensure treatment success. Imaging modalities are necessarily used in dentistry for treatment planning and dental procedures. Three-dimensional image reconstruction not only provides visual information but also enables accurate measurement of anatomical structures; thus, it is necessarily required for maxillofacial examination and in case of skeletal problems in this region. Aims: This study aimed to assess the ability of three Cone Beam Computed Tomography (CBCT) systems including Cranex 3D, NewTom 3G and 3D Promax for Three-Dimensional (3D) image reconstruction of the cortical plate with variable thicknesses. Methods: Depending on the cortical bone thickness, samples were evaluated in three groups of ≤ 0. 5 mm, 0.6 -1 mm and 1.1-1.5 mm cortical bone thickness. The CBCT scans were obtained from each sample using three systems, their respective FOVs, and 3D scans were reconstructed using their software programs. Two observers viewed the images twice with a two-week interval. The ability of each system in the 3D reconstruction of different thicknesses of cortical bone was determined based on its visualization on the scans. The data were analyzed using SPSS and Kappa test. Results: The three systems showed the greatest difference in the 3D reconstruction of cortical bone with < 0.5 mm thickness. Cranex 3D with 4×6 cm2 FOV had the highest and 3D Promax with 8×8 cm2 FOV had the lowest efficacy for 3D reconstruction of cortical bone. Cranex 3D with 4×6 cm2 and 6×8 cm2 FOVs and NewTom 3G with 5×5 cm2 and 8×5 cm2 FOVs showed significantly higher efficacy for 3D reconstruction of cortical bone with 0.6-1mm thickness while 3D Promax followed by NewTom 3G with 8×8 cm2 FOV had the lowest efficacy for this purpose. Conclusion: Most CBCT systems have high efficacy for 3D image reconstruction of cortical bone with thicknesses over 1 mm while they have poor efficacy for image reconstruction of cortical bone with less than 0.5 mm thickness. Thus, for accurate visualization of anatomical structures on CBCT scans, systems with smaller FOVs and consequently smaller voxel size are preferred.


  • Open Access

    Diagnostic Accuracy of Three Cone Beam Computed Tomography Systems and Periapical Radiography for Detection of Fenestration Around Dental Implants

    by Amir Eskandarloo, Samira Saati, Mahbubeh Purabdolahi Ardakani, Mohamadreza Jamalpour, Naser Mohammad Gholi Mezerji, Vahid Akheshteh

    Context: Early detection of peri-implant bone defects is highly important to prevent further bone loss and implant failure. Aims: This study aimed to assess the diagnostic accuracy of three cone-beam computed tomography (CBCT) systems and periapical radiography for detection of fenestration around dental implants. Methods: Thirty-one titanium implants were placed in the bovine ribs, in which peri-implant fenestration were simulated. Using a round fissure bur, fenestration defects were created in the apical-third region of implants. CBCT and PA radiographs were obtained before and after creating the defects. The results were analyzed using Chi-square test; kappa coefficient; Cochran's Q-test; McNemar's test; and sensitivity, specificity, positive predictive value, and negative predictive value; and receiver operating characteristic curve. Results: A significant agreement was noted between the two observers in the detection of defect-free samples in all imaging systems (P < 0.05). In detection of samples with defects, a significant agreement was observed between the two observers in use of Cranex three-dimensional and NewTom 3G systems (P < 0.05), but the agreement was not significant for detection of defects in use of Promax 3D (P > 0.05). The results showed no significant difference among the four imaging systems in detection of defect-free samples while the difference was significant among the four groups for detection of defects (P < 0.05). NewTom had the highest sensitivity (75.81%) and specificity (100%) for detection of fenestration. Conclusions: Within the limitations of CBCT systems different kVp used by different systems, artifacts and noises that influences image quality, difference in diagnostic value of different CBCT systems is due to the differences in type of detector and voxel size. In terms of the type of detector, our results showed that NewTom 3G, which has a higher (kVP) than other systems and the highest accuracy for detection of fenestration.


  • Open Access

    Comparison of Two Cone-Beam Computed Tomography Systems Regarding Linear Measurement Accuracy for Implant Sites in the Mandible: An In-Vitro Study

    by Amir Eskandarloo, Abbas Shokri, Aydin Salehi Milani, Mohammad Reza Jamalpoor, Karim Ghazikhanlou-Sani


  • Open Access

    Iatrogenic Errors during Root Canal Instrumentation Performed by Dental Students

    by Seyedeh Sareh Hendi, Hamed Karkehabadi, Amir Eskandarloo

    The present study was set to investigate the training quality and its association with the quality of root canal therapy performed by fifth year dentistry students. A total number of 432 records of endodontic treatment performed by fifth year dentistry students were qualified to be further investigated. Radiographs were assessed by two independent endodontists. Apical transportation, apical perforation, gouging, ledge formation, and the quality of temporary restoration were error types investigated in the present study. the prevalence of apical transportation, ledge formation, and apical perforation errors were significantly higher in molars in comparison with other types of teeth. The most prevalent type of error was the apical transportation, which was significantly higher in mandibular teeth. There was no significant differences among teeth in terms of other types of errors. The quality of training provided for dentistry students should be improved and endodontic curriculum should be modified.