A Comparison of Espocan® and Tuohy Needles for the Combined Spinal-Epidural Technique for Labor Analgesia
Authors:
- David J. BirnbachDBDavid J. Birnbach
- Deborah J. SteinDSDeborah J. Stein
- David A. OʼgormanDODavid A. Oʼgorman
- Maxine KurodaMKMaxine Kuroda
- 1 August 2005
- journal article
- clinical trial
- Published by Wolters Kluwer Health in Anesthesia & Analgesia
- Vol. 101 (2) , 535-540
Abstract
When using the needle-through-needle combined spinal-epidural (CSE) technique for labor analgesia, failure to obtain cerebrospinal fluid (CSF), paresthesias, and intrathecal or intravascular migration of the catheter are of concern. Epidural needles with spinal needle apertures, such as the back-hole Espocan (ES) needles, are available and may reduce these risks. We describe the efficacy and adverse events associated with a modified epidural needle (ES) versus a conventional Tuohy needle for CSE. One-hundred parturients requesting labor analgesia (CSE) were randomized into 2 groups: 50-ES 18-gauge modified epidural needle with 27-gauge Pencan atraumatic spinal needle, 50-conventional 18-gauge Tuohy needle with 27-gauge Gertie Marx atraumatic spinal needle. Information on intrathecal or intravascular catheter placement, paresthesia on introduction of spinal needle, failure to obtain CSF through the spinal needle after placement of epidural needle, unintentional dural puncture, and epidural catheter function was obtained. No intrathecal catheter placement occurred in either group. Rates of intravascular catheter placement and unintentional dural puncture were similar between the groups. Significant differences were noted regarding spinal needle-induced paresthesia (14% ES versus 42% Tuohy needles, P = 0.009) and failure to obtain CSF on first attempt (8% ES versus 28% Tuohy needles, P < 0.02). Use of ES needles for CSE significantly reduces paresthesia associated with the insertion of the spinal needle and is associated with more frequent successful spinal needle placement on the first attempt. The use of modified epidural needles with a back hole for combined spinal-epidural technique significantly reduces paresthesia associated with the insertion of the spinal needle and is associated with more frequent successful spinal needle placement on the first attempt.Keywords
This publication has 14 references indexed in Scilit:
- A Comparison of the 24-Gauge Sprotte®and Gertie Marx®Spinal Needles for Combined Spinal-Epidural Analgesia during LaborAnesthesiology, 2002
- Current Issues in Spinal AnesthesiaAnesthesiology, 2001
- THE COMBINED SPINAL-EPIDURAL TECHNIQUEAnesthesiology Clinics of North America, 2000
- The Epidural Test Dose in Obstetric PatientsAnesthesia & Analgesia, 1999
- A Clinical Comparison Between Needle-Through-Needle and Double-Segment Techniques for Combined Spinal and Epidural AnesthesiaRegional Anesthesia & Pain Medicine, 1998
- An In Vivo Evaluation of Four Spinal Needles Used for the Combined Spinal-Epidural TechniqueAnesthesia & Analgesia, 1998
- Serious Complications Related to Regional AnesthesiaAnesthesiology, 1997
- Accidental intrathecal insertion of an extradural catheter during combined spinal-extradural anaesthesia for caesarean sectionBritish Journal of Anaesthesia, 1995
- Combined epidural/spinal anaesthesia for Caesarean sectionAnaesthesia, 1992
- A comparison of two types of epidural cathetersCanadian Journal of Anesthesia/Journal canadien d'anesthésie, 1987