Newborn screening for 3‐hydroxy‐3‐methylglutaric aciduria using direct analysis in real‐time mass spectrometry
- 23 November 2018
- journal article
- research article
- Published by Wiley in Journal of Mass Spectrometry
- Vol. 54 (2) , 134-140
Abstract
A novel method utilizing ambient thermal desorption ionization with a direct analysis in real‐time source integrated with mass spectrometry (DART‐MS) was established and applied to the rapid analysis of 3‐hydroxy‐3‐methylglutaric (3‐HMG) acid in the neonatal urine. Instrument parameter settings were optimized to obtain high sensitive and accurate determination of 3‐HMG acid. The use of helium gas heated to temperature of 400 oC was observed to permit deprotonation, 3‐HMG acid producing a abundant [M‐H]‐ (m/z 161) in the negative ion mode. The calibration curve was determined to be linear over the range of 0.05‐5 mg/L, with the correlation coefficient r = 0.9988 and the relative standard deviations (n=6) in the range of 1.5 to 11.8%. The limit of detection was 0.002 mg/L and the limit of quantitation was 0.007 mg/L. The recoveries ranged from 88.0% to 123.1%. Four urine samples from patients and four simulated urine samples were investigated. The results of DART‐MS were in agreement with the values determined using established methods at the hospitals. The proposed method demonstrated significant potential in the application of the high‐throughput screening in newborn screening.Keywords
Funding Information
- National Natural Science Foundation of China (51503182)
This publication has 32 references indexed in Scilit:
- Principal component analysis of urine metabolites detected by NMR and DESI–MS in patients with inborn errors of metabolismAnalytical and Bioanalytical Chemistry, 2006
- Newborn Screening by Tandem Mass SpectrometryClinical Chemistry, 2001
- [Organic aciduria: diagnosis in high-risk Brazilian patients]Jornal de Pediatria, 2001
- IN-BORN METABOLIC DISORDERS: THIN-LAYER (PLANAR) CHROMATOGRAPHY2000
- Selective screening for inborn errors of metabolism — past, present and futureEuropean Journal of Pediatrics, 1994
- Rapid diagnosis of 3-hydroxy-3-methylglutaryl—coenzyme A lyase deficiency via enzyme activity measurements in leukocytes or platelets using a simple spectrophotometric methodClinica Chimica Acta, 1990
- The incorporation of 3-hydroxy-3-methylglutaric acid into the lactone ring of dioscorine in Dioscorea hispidaPhytochemistry, 1989
- Organic Acids in Man1982
- The urinary organic acid profile associated with 3-hydroxy-3-methylglutaric aciduriaClinica Chimica Acta, 1976
- 3-hydroxy-3-methylglutaric aciduria: 3-Hydroxy-3-methylglutaryl-coenzyme a lyase levels in leucocytesClinica Chimica Acta, 1976