YLYanshuxian Liu

Yanshuxian Liu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Yanshuxian Liu has a total of 7 co-authors. Here are the top co-authors by number of shared publications:

  • Charles Liu

    Technical Department, ASPEC Technologies Limited, Beijing, China

    1 shared publication
  • Huijun Liu

    College of Chemical Engineering, Zhejiang University of Technology, Hangzhou, China

    1 shared publication
  • Lili Wang

    College of Chemical Engineering Zhejiang University of Technology Hangzhou Zhejiang P. R. China

    1 shared publication
  • Xiaoli Huang

    College of Chemical Engineering, Zhejiang University of Technology, Hangzhou, China

    1 shared publication
  • Yiping Ren

    National Center for Food Safety Risk Assessment Application Technology Cooperation Center, Yangtze Delta Region Institute of Tsinghua University, Jiaxing, China

    1 shared publication
  • Zhengzheng Hu

    Department of Genetics and Metabolism, Children's Hospital, Zhejiang University, Hangzhou, China

    1 shared publication

Latest Publications

  • Newborn screening for 3‐hydroxy‐3‐methylglutaric aciduria using direct analysis in real‐time mass spectrometry

    by Zhongping Huang, Yanshuxian Liu, Xiaoli Huang, Zhengzheng Hu, Huijun Liu, Lili Wang, Charles Liu, Yiping Ren

    A novel method utilizing ambient thermal desorption ionization with a direct analysis in real‐time source integrated with mass spectrometry (DART‐MS) was established and applied to the rapid analysis of 3‐hydroxy‐3‐methylglutaric (3‐HMG) acid in the neonatal urine. Instrument parameter settings were optimized to obtain high sensitive and accurate determination of 3‐HMG acid. The use of helium gas heated to temperature of 400 oC was observed to permit deprotonation, 3‐HMG acid producing a abundant [M‐H]‐ (m/z 161) in the negative ion mode. The calibration curve was determined to be linear over the range of 0.05‐5 mg/L, with the correlation coefficient r = 0.9988 and the relative standard deviations (n=6) in the range of 1.5 to 11.8%. The limit of detection was 0.002 mg/L and the limit of quantitation was 0.007 mg/L. The recoveries ranged from 88.0% to 123.1%. Four urine samples from patients and four simulated urine samples were investigated. The results of DART‐MS were in agreement with the values determined using established methods at the hospitals. The proposed method demonstrated significant potential in the application of the high‐throughput screening in newborn screening.