Performance of the redesigned inductively driven transmission line current diagnostic for the Z pulsed power facility
Authors:
- Stacie HernandezSHStacie Hernandez
- Katherine M. ChandlerKCKatherine M. Chandler
- Brian T. HutselBHBrian T. Hutsel
- Carlos AragonCACarlos Aragon
- Dustin J. MarshallDMDustin J. Marshall
- Matthew R. GomezMGMatthew R. Gomez
- Christopher A. JenningsCJChristopher A. Jennings
- Joshua J. LeckbeeJLJoshua J. Leckbee
- Edl SchamilogluESEdl Schamiloglu
- 1 August 2026
- journal article
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (8)
Abstract
A redesign of the inductively driven transmission line (IDTL) current monitor took place due to the discovery of the discrepancy between the magnetic field measurements of the two B-dots sensors. The IDTL redirects a small amount of Z’s magnetic energy by passively coupling to the magnetic fields of the final power feed of the machine. The monitor is composed of a pair of B-dots oppositely oriented to measure the current that is siphoned through the secondary circuit, enabling common-mode noise cancellation. The redesign of the current monitor will not only enable the diagnostic to measure comparable magnetic fields between the two monitors but also will maintain its compact design while completing common-mode noise elimination. The discrepancy measurements of the magnetic field were identified through simulations (conducted in COMSOL Multiphysics) and calibration measurements that displayed a sensitivity difference by a factor of two. The redesigned IDTL monitor will correct this discrepancy and increase accuracy on the electrical measurements for Z experiments.Keywords
Funding Information
- National Nuclear Security Administration
This publication has 6 references indexed in Scilit:
- Modeled sensitivity of multi-MA accelerator performance to electrode contaminant inventoryPhysics of Plasmas, 2025
- Radiation, optical, power flow, and electrical diagnostics at the Z facility: Layout and techniques utilized to operate in the harsh environmentReview of Scientific Instruments, 2023
- The inductively driven transmission line: A passively coupled device for diagnostic applications on the Z pulsed power facilityReview of Scientific Instruments, 2021
- Review of pulsed power-driven high energy density physics research on Z at SandiaPhysics of Plasmas, 2020
- -A load-current-dot monitor: Simulations, design, and performancePhysical Review Special Topics - Accelerators and Beams, 2010
- Differential-output-dot and-dot monitors for current and voltage measurements on a 20-MA, 3-MV pulsed-power acceleratorPhysical Review Special Topics - Accelerators and Beams, 2008