Stacie Hernandez
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Stacie Hernandez has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
Albuquerque Sandia National Laboratories (Snl-Nm)
2 shared publications- Brian Stoltzfus
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
2 shared publications - Brian Thomas Hutsel
Sandia National Laboratories
2 shared publications Joseph Felix
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
2 shared publications- Joshua Leckbee
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
2 shared publications - Adam Michael Steiner
Sandia National Laboratories (SNL-NM), Albuquerque, NM (United States)
1 shared publication
Latest Publications
- 1 August 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (8)
Performance of the redesigned inductively driven transmission line current diagnostic for the Z pulsed power facility
A redesign of the inductively driven transmission line (IDTL) current monitor took place due to the discovery of the discrepancy between the magnetic field measurements of the two B-dots sensors. The IDTL redirects a small amount of Z’s magnetic energy by passively coupling to the magnetic fields of the final power feed of the machine. The monitor is composed of a pair of B-dots oppositely oriented to measure the current that is siphoned through the secondary circuit, enabling common-mode noise cancellation. The redesign of the current monitor will not only enable the diagnostic to measure comparable magnetic fields between the two monitors but also will maintain its compact design while completing common-mode noise elimination. The discrepancy measurements of the magnetic field were identified through simulations (conducted in COMSOL Multiphysics) and calibration measurements that displayed a sensitivity difference by a factor of two. The redesigned IDTL monitor will correct this discrepancy and increase accuracy on the electrical measurements for Z experiments.
- 1 August 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (8)
Performance of the redesigned inductively driven transmission line current diagnostic for the Z pulsed power facility
A redesign of the inductively driven transmission line (IDTL) current monitor took place due to the discovery of the discrepancy between the magnetic field measurements of the two B-dots sensors. The IDTL redirects a small amount of Z’s magnetic energy by passively coupling to the magnetic fields of the final power feed of the machine. The monitor is composed of a pair of B-dots oppositely oriented to measure the current that is siphoned through the secondary circuit, enabling common-mode noise cancellation. The redesign of the current monitor will not only enable the diagnostic to measure comparable magnetic fields between the two monitors but also will maintain its compact design while completing common-mode noise elimination. The discrepancy measurements of the magnetic field were identified through simulations (conducted in COMSOL Multiphysics) and calibration measurements that displayed a sensitivity difference by a factor of two. The redesigned IDTL monitor will correct this discrepancy and increase accuracy on the electrical measurements for Z experiments.
- Open Access
- 1 June 2023
- Published by Office of Scientific and Technical Information (OSTI)
Triggering a high-pressure, high-voltage, air switch with an off-axis laser
- 1 June 2023
- Published by Office of Scientific and Technical Information (OSTI)
Open AccessTriggering a high-pressure, high-voltage, air switch with an off-axis laser