Assessment of the rotator cuff and glenoid labrum using an extremity MR system: MR results compared to surgical findings from a multi‐center study
Open Access
- 21 April 2004
- journal article
- research article
- Published by Wiley in Journal of Magnetic Resonance Imaging
- Vol. 19 (5) , 623-631
Abstract
Purpose: To conduct a multi‐center assessment of the use of a 0.2‐T, extremity MR system (E‐scan; General Electric Lunar Corp. and Esaote, Genoa, Italy) for identifying tears of the rotator cuff and glenoid labrum.Materials and Methods: A retrospective study was performed involving 160 patients (age range, 15–84 years old) from five facilities in the United States, comparing shoulder MR imaging to surgical findings. MR imaging of the shoulder was conducted as follows: shoulder coil; T1‐weighted spin echo, coronal‐oblique and axial images; short Tau inversion recovery (STIR), coronal‐oblique images and axial images; and T2‐weighted spin echo, coronal‐oblique and sagittal‐oblique images. The MR examinations were interpreted in an independent, prospective manner by two radiologists with extensive musculoskeletal MRI experience. Arthroscopic (N = 103) or open surgical (N = 57) procedures were performed within a mean of 53 days after MR imaging.Results: Surgical findings demonstrated rotator cuff tears in 131 patients and labral tears in 60 patients. For the rotator cuff, the sensitivity, specificity, positive predictive value, and negative predictive value were 90%, 93%, 98%, and 68%, respectively. For the labrum, the sensitivity, specificity, positive predictive value, and negative predictive value were 55%, 100%, 100%, and 82%, respectively.Conclusions: There was good agreement when MR results obtained using the extremity MR system were compared to surgical findings for identifying rotator cuff tears, while the sensitivity of MR imaging for determining labral tears was relatively poor. Nevertheless, these findings were comparable to those reported in the peer‐reviewed literature for MR systems operating at mid‐, and high‐field‐strengths. J. Magn. Reson. Imaging 2004;19:623–631.Keywords
This publication has 32 references indexed in Scilit:
- MR Arthrography of the Posterior Labrocapsular Complex: Relationship with Glenohumeral Joint Alignment and Clinical Posterior InstabilityAmerican Journal of Roentgenology, 2003
- In-office MR imagingClinics in Sports Medicine, 2002
- MR arthrographic variability of the arthroscopically normal glenoid labrum: qualitative and quantitative assessmentEuropean Radiology, 2001
- High-Field and Low-Field MR Imaging of Superior Glenoid Labral Tears and Associated Tendon InjuriesAmerican Journal of Roentgenology, 2000
- Direct MR Arthrography: A Review of Current UseClinical Radiology, 2000
- Magnetic Resonance Diagnosis of the Anterior Labrum and CapsuleInvestigative Radiology, 1998
- Magnetic resonance imaging assessment of the rotator cuff: Is it really accurate?Arthroscopy, 1997
- MR arthrography of the shoulder: rethinking traditional imaging procedures to meet the technical requirements of MR imaging guidance.American Journal of Roentgenology, 1997
- MR diagnosis of rotator cuff tears of the shoulder: value of using T2-weighted fat-saturated images.American Journal of Roentgenology, 1995