Ocular Biometric and Corneal Biomechanical Changes Following Ahmed Glaucoma Valve Implantation in Neovascular Glaucoma

Authors:
  • AAAli Azimi
    Ali Azimi
  • AMAidin Meshksar
    Aidin Meshksar
  • HRHooman Razmi
    Hooman Razmi
  • AFAmirmohammad Fathian
    Amirmohammad Fathian
  • AAAlireza Attar
    Alireza Attar
  • AYAdele Yarmohammadi
    Adele Yarmohammadi

Abstract
Background: To evaluate the impact of Ahmed glaucoma valve (AGV) implantation on ocular biometric and corneal biomechanical parameters in neovascular glaucoma (NVG) patients. Methods: This prospective study included 18 eyes of 18 NVG patients undergoing AGV implantation. Biometrical parameters, including anterior chamber depth(ACD), axial lenghth(AL) and keratometric values in addition to corneal biomechanical indices(deformation amplitude, peak distance, applanation lenghths and velocities) , were assessed preoperatively and three months postoperatively. Statistical analysis evaluated changes and correlations between parameters. Results: The mean age of the subjects was 57.44 (±10.325). The mean preoperative IOP was 36.65(±12.3) mmHg, which was reduced to 15.5(±2.64) mmHg post-operatively (p value 0.05). Conclusion: AGV implantation induces significant ocular biometric and corneal biomechanical changes in NVG patients. Understanding these alterations is vital for optimizing treatment strategies and clinical outcomes in NVG management.

This publication has 15 references indexed in Scilit: