An ADRC-Based Control Strategy for FRT Improvement of Wind Power Generation with a Doubly-Fed Induction Generator
Open Access
Abstract
This paper proposes a second-order active disturbance rejection control (ADRC)-based control strategy with an integrated design of the flux damping method, for the fault ride-through (FRT) improvement in wind power generation systems with a doubly-fed induction generator (DFIG). First, a first principles model of the rotor and grid side converter of DFIG is developed, which is then used to theoretically analyze the system characteristics and show the damage caused to the DFIG system by a grid voltage fault. Then, the flux damping method is used to suppress the rotor current during a fault ride-through. In order to enhance the robustness and effectiveness of the flux damping method under complex working conditions, an ADRC approach is proposed for disturbance attenuation of the DFIG systems. Finally, a comparison of the proposed method with three other control approaches on a 1.5-MV DFIG system benchmark is performed. It is shown that the proposed method can adaptively and effectively improve the system performance during an FRT.Keywords
Funding Information
- National Natural Science Foundation of China (61673053)
- The Beijing Natural Science Foundation (4162041)
- the National Key R&D Program of China (2017YFB0306403)
This publication has 20 references indexed in Scilit:
- Comprehensive Reactive Power Support of DFIG Adapted to Different Depth of Voltage SagsEnergies, 2017
- Controllable DC‐link fault current limiter augmentation with DC chopper to improve fault ride‐through of DFIGIET Renewable Power Generation, 2017
- The Economics of Wind Power in China and Policy ImplicationsEnergies, 2015
- Analysis of the control limit for rotor‐side converter of doubly fed induction generator‐based wind energy conversion system under various voltage dipsIET Renewable Power Generation, 2013
- An LVRT Control Strategy Based on Flux Linkage Tracking for DFIG-Based WECSIEEE Transactions on Industrial Electronics, 2012
- Impacts of Symmetrical and Asymmetrical Voltage Sags on DFIG-Based Wind Turbines Considering Phase-Angle Jump, Voltage Recovery, and Sag ParametersIEEE Transactions on Power Electronics, 2010
- Minimum-Threshold Crowbar for a Fault-Ride-Through Grid-Code-Compliant DFIG Wind TurbineIEEE Transactions on Energy Conversion, 2010
- Rotor Voltage Dynamics in the Doubly Fed Induction Generator During Grid FaultsIEEE Transactions on Power Electronics, 2009
- A Fault Tolerant Doubly Fed Induction Generator Wind Turbine Using a Parallel Grid Side Rectifier and Series Grid Side ConverterIEEE Transactions on Power Electronics, 2008
- Doubly Fed Induction Generator Systems for Wind Turbines: A Viable Alternative to Adjust Speed over a Wide Range at Minimal CostIEEE Industry Applications Magazine, 2002