Decision support system to evaluate VENTilation in the Acute Respiratory Distress Syndrome (DeVENT study) – Trial Protocol
Preprint
Abstract
Background: The Acute Respiratory Distress Syndrome (ARDS) occurs in response to a variety of insults, and mechanical ventilation is life-saving in this setting, but ventilator induced lung injury can also contribute to the morbidity and mortality in the condition. The Beacon Caresystem is a model-based bedside decision support system using mathematical models tuned to the individual patient’s physiology to advise on appropriate ventilator settings. Personalised approaches using individual patient description may be particularly advantageous in complex patients, including those who are difficult to mechanically ventilate and wean, in particular ARDS. Methods: We will conduct a multi-centre international randomised, controlled, allocation concealed, open, pragmatic clinical trial to compare mechanical ventilation in ARDS patients following application of the Beacon Caresystem to that of standard routine care to investigate whether use of the system results in a reduction in driving pressure across all severities and phases of ARDS. Discussion: Despite 20 years of clinical trial data showing significant improvements in ARDS mortality through mitigation of ventilator induced lung injury, there remains a gap in its personalised application at the bedside. Importantly, the protective effects of higher positive end-expiratory pressure (PEEP) were noted only when there were associated decreases in driving pressure. Hence, the pressures set on the ventilator should be determined by the diseased lungs’ pressure-volume relationship which is often unknown or difficult to determine. Knowledge of extent of recruitable lung could improve the ventilator driving pressure. Hence, personalised management demands the application of mechanical ventilation according to the physiological state of the diseased lung at that time. Hence, there is significant rationale for the development of point-of-care clinical decision support systems which help personalise ventilatory strategy according to the current physiology. Furthermore, the potential for the application of the Beacon Caresystem to facilitate local and remote management of large numbers of ventilated patients (as seen during this COVID-19 pandemic), could change the outcome of mechanically ventilated patients during the course of this and future pandemics. Trial registration: ClinicalTrials.gov identifier ( NCT number): NCT04115709 Administrative information: Note: the numbers in curly brackets in this protocol refer to SPIRIT checklist item numbers. The order of the items has been modified to group similar items (see http://www.equator-network.org/reporting-guidelines/spirit-2013-statement-defining-standard-protocol-items-for-clinical-trials/ ).Keywords
All Related Versions
- Published version: Trials, 23 (1), 1.
This publication has 20 references indexed in Scilit:
- Prone Positioning in Severe Acute Respiratory Distress SyndromeThe New England journal of medicine, 2013
- Lung protective mechanical ventilation and two year survival in patients with acute lung injury: prospective cohort studyBMJ, 2012
- Minimal model quantification of pulmonary gas exchange in intensive care patientsMedical Engineering & Physics, 2010
- Reproduction of inert gas and oxygenation data: a comparison of the MIGET and a simple model of pulmonary gas exchangeIntensive Care Medicine, 2010
- Mathematical modelling of the acid–base chemistry and oxygenation of blood: a mass balance, mass action approach including plasma and red blood cellsEuropean Journal of Applied Physiology, 2009
- Variation in the PaO2/FiO2 ratio with FiO2: mathematical and experimental description, and clinical relevanceCritical Care, 2007
- Using physiological models and decision theory for selecting appropriate ventilator settingsJournal of Clinical Monitoring and Computing, 2006
- Reproduction of MIGET retention and excretion data using a simple mathematical model of gas exchange in lung damage caused by oleic acid infusionJournal of Applied Physiology, 2006
- Comparison of Two Fluid-Management Strategies in Acute Lung InjuryThe New England journal of medicine, 2006
- Modelling of hypoxaemia after gynaecological laparotomyActa Anaesthesiologica Scandinavica, 2001